2021-11-15 16:57:37FROM: RAY CARANCI, SENIOR LANDSCAPE PLANNER
 561-822-1462
 PROJECT: 1001 OKEECHOBEE Z21100021
 NOVEMBER 15, 2021
 I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND
 PROVIDE THE FOLLOWING COMMENTS:
  
  
 1. SECTION 94-448 (D)(3) REQUIRES NATIVE TREES AND
 PALMS IN GOOD CONDITION TO BE PRESERVED ON SITE OR
 RELOCATED. ANSI A 300 (PART 5) STANDARDS SPECIFY
 EXAMPLES OF SUITABILITY RATINGS OF GOOD, MODERATE, OR
 POOR FOR RELOCATION. PROVIDE AN ARBORISTS REPORT RATING
 THE CONDITION AND RELOCATION POTENTIAL FOR THE NATIVE
 TREES AND PALMS. THERE ARE LIVE OAKS, SABAL PALMS,
 FLORIDA THATCH PALMS, AND ROYAL PALMS THAT ARE
 INDICATED TO BE REMOVED. NON NATIVE TREES AND PALMS ARE
 NOT REQUIRED TO BE RELOCATED.
 2. MAKE THE FOLLOWING CORRECTIONS TO THE TREE
 DISPOSITION LIST:
 ? ONLY TREES PROPOSED TO BE REMOVED WITH A CANOPY
 DIAMETER OF 20 FEET OR MORE SHOULD HAVE THE MITIGATION
 SQUARE FOOTAGE CALCULATED BASED ON THE ACTUAL DIAMETER.
 TREES LESS THAN 20 FEET CANOPY DIAMETER AND PALMS
 SHOULD SHOW THE CATEGORY MITIGATION DUE.
 ? MULTIPLE PALMS PLANTED TOGETHER MUST HAVE EACH SINGLE
 TRUNK COUNTED TOWARD MITIGATION. TRIPLE ADONIDIA WOULD
 BE 3 X 50 SQ FT.
  
 3. PROVIDE A DIAGRAM OF THE REQUIRED AND PROVIDED
 PUBLIC AND PRIVATE OPEN SPACE AREAS FOR CLD 25 ZONING
 DISTRICT. IDENTIFY THE TYPE OF OPEN SPACE AS ALLOWED BY
 TABLE IV-7 AND DEFINITIONS IN SECTION 94-109. SHOW HOW
 THE STANDARDS FOR THE TYPES OF OPEN SPACE ARE MET FOR
 VEGETATED AREAS AND TREE CANOPY SQUARE FOOTAGE BASED ON
 TABLE IV-8 ON THE LANDSCAPE PLAN. DIAGRAM ON SHEET
 A0.07 DOES NOT IDENTIFY THE OPEN SPACE TYPE OR CALL OUT
 HOW THE REQUIREMENTS OF THAT TYPE ARE MET.
 THE REQUIRED OPEN SPACE NEEDS TO BE QUANTIFIED,
 IDENTIFIED AS TO THE TYPE, AND ALL REQUIREMENTS NEED TO
 BE SHOWN FOR THAT OPEN SPACE TYPE. FOR OPEN SPACE SHOW
 THE TREE CANOPY SQUARE FOOTAGE FOR TREE TYPES BASED ON
 TABLE IV-8.
  
 4. IDENTIFY RELOCATED TREES OR PALMS ON THE PLANT LIST
 AND COUNT THEM TOWARD THE REQUIRED TREES.
 5. ALL EXISTING LANDSCAPING MUST BE SHOWN ON THE
 LANDSCAPE PLAN TO PROVIDE A COMPLETE PLAN SHOWING
 COMPLIANCE WITH CURRENT CODE REQUIREMENTS.
  
 6. ARTIFICIAL TURF AREAS PROPOSED MUST MEET THE
 REQUIREMENTS OF SECTION 94-451, INCLUDING ALL AREAS
 THAT ARE ALLOWED BY CODE MUST NOT BE VISIBLE FROM A
 ROAD OR STREET.
  
  
  
 7. BUFFER TREES AND HEDGES MUST BE PROVIDED ALONG ALL
 BUFFERS. THERE IS A LARGE GAP ADJACENT TO THE WEST
 PARKING GARAGE.
  
 8. PROVIDE CALCULATIONS FOR REQUIRED STREET TREES AT
 MAXIMUM SPACING EVERY 30 FEET OR PORTION THEREOF FOR
 THE OKEECHOBEE STREETSCAPE LENGTH, AND SHOW THE NUMBER
 PROVIDED PER SECTION 94-113 AND 94-116.
  
  
 9. SHOW ALL EXISTING AND PROPOSED WATER AND SEWER AND
 DRAINAGE LINES ON THE LANDSCAPE PLAN. SHOW LOCATIONS OF
 BACKFLOWS AND ADJUST LOCATIONS OF UTILITY LINES TO
 RESOLVE CONFLICTS WITH EXISTING AND PROPOSED TREES AND
 LANDSCAPING.
  
 10. PLANT LIST NEEDS TO BE MODIFIED TO SEPARATE THE
 REQUIRED OPEN SPACE PLANT LISTS.
  
 11. NATAL PLUM IS NOT A FLORIDA NATIVE PLANT.
  
 12. SEAGRAPE IS SHOWN ON SHEET L-450, BUT NO SEAGRAPE
 IS PROPOSED ON PLANT LIST.
  
 13. PROVIDE THE 50 REQUIRED FLORIDA FRIENDLY POINTS
 BASED ON THE FINAL PLANT LIST PER SECTION 94-443(G).
  
 14. SHOW COMPLIANCE WITH SECTION 94-445 L. PLANT
 SPECIES. A MINIMUM OF 60 PERCENT OF PLANT MATERIAL
 ADDED SHALL BE FLORIDA NATIVE OR DROUGHT TOLERANT
 SPECIES SELECTED FROM THE CITY LIST OR THE LIST OF
 SPECIES IN THE MOST RECENT EDITION OF SOUTH FLORIDA
 WATER MANAGEMENT DISTRICT WATERWISE SOUTH FLORIDA
 LANDSCAPES. PROVIDE THE ACTUAL PERCENTAGE BASED ON THE
 PLANT LIST.
  
  
 15. ALL SURFACE PARKING MUST MEET THE REQUIREMENTS OF
 SECTION 94-443(C)(3) A. INCLUDING TERMINAL LANDSCAPE
 ISLANDS, INTERIOR ISLANDS AND SHADE TREES.
 16. PROVIDE AN EXHIBIT SHOWING THE PARKING AREA SURFACE
 CALCULATIONS, PARKING SPACE AREAS AND LANDSCAPE AREAS
 PROVIDED TO DEMONSTRATE COMPLIANCE WITH SECTIONS 94-443
 (C)(3) AND (4). PROVIDE THE CALCULATIONS IN THE
 LANDSCAPE REQUIREMENT CHART. REFER TO FIGURE XIV-1.
  
 17. PROVIDE SCREENING HEDGES FOR ALL GROUND MOUNTED
 VALVES AND EQUIPMENT AND ADD A NOTE THAT ALL EQUIPMENT
 WILL BE SCREENED.
 CONDITIONS OF APPROVAL
 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON
 THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE
 SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT
 SERVICES DEPARTMENT, PLANNING DIVISION.
  