| 2023-06-01 16:08:15 | FROM: LINDA LOUIE, SENIOR PLANNER, 561.822.1458/SMITH |
| | AMISIAL, LANDSCAPE PLANNER, 561.822.1562 |
| | PROJECT: FSPR 21-05 (Z21100018): CURRIE PARK |
| | REDEVELOPMENT |
| | DATE: JUNE 1, 2022 |
| | _______________________________________________________ |
| | |
| | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND |
| | PROVIDE THE FOLLOWING COMMENTS: |
| | |
| | 1. MAKE THE FOLLOWING CORRECTIONS TO THE TREE |
| | DISPOSITION PLAN: |
| | |
| | 1.1 SATISFIED. X SYMBOL ON TREE DISPOSITION PLANS |
| | REPRESENTS REMOVALS AND RELOCATIONS. USE THE X SYMBOL |
| | FOR REMOVALS ONLY AND PROVIDE A DIFFERENT SYMBOL FOR |
| | RELOCATIONS. |
| | |
| | 1.2 SATISFIED. PLACE HEADINGS FOR COLUMNS ON ALL |
| | DISPOSITION LIST SHEETS. |
| | |
| | 1.3 SATISFIED. ADD A COLUMN FOR TREE CATEGORY TO THE |
| | DISPOSITION LIST SHEETS. |
| | |
| | 1.4 NOT SATISFIED. FOR TREES LESS THAN 20 FEET CANOPY |
| | DIAMETER AND PALMS THE CANOPY SQUARE FOOTAGE TO BE |
| | MITIGATED IS BASED ON CATEGORY. LIVE OAK CATEGORY 1 IS |
| | 300 SQ FT, CATEGORY 2 IS 150 SQ FT, CATEGORY 3 IS 100 |
| | SQ FT, CATEGORY 4 IS 50 SQ FT. COUNT NUMBER OF TRUNKS |
| | TIMES CATEGORY VALUE. APPLICANT HAS STATED THIS WILL BE |
| | PROVIDED IN A LATER SUPPLEMENT. |
| | |
| | 1.5 NOT SATISFIED.CORRECTIONS MUST BE MADE TO TREE |
| | DISPOSITION CHART: CHINESE FAN PALM AND COCONUT PALMS |
| | ARE NOT INVASIVES. PLEASE PROVIDE THEIR CANOPY SQ |
| | FOOTAGE. PALM SQUARE FOOTAGE MUST BE PROVIDED THROUGH |
| | CATEGORY 3 OR CATEGORY 4 (SEE CATEGORY LIST FOR |
| | DETAILS). IT CANNOT BE SHOWN AS 1 FOR 1. PROVIDE THE |
| | TOTAL CANOPY SQUARE FOOTAGE THEREAFTER. |
| | |
| | 1.6 NOT SATISFIED. JAVA BISHOPWOOD AND INDIAN LAUREL |
| | FIG ARE NOT INVASIVES. PLEASE PROVIDE THEIR CANOPY |
| | SQUARE FOOTAGE AND INCLUDE IT IN MITIGATION |
| | CALCULATIONS. |
| | |
| | 1.7 NOT SATISFIED. CATEGORY 2 TREES REPRESENT 150 |
| | SQUARE FT OF CREDIT. HOW IS THE TOTAL 1801? |
| | |
| | 1.8 NOT SATISFIED. PROVIDE THE TOTAL SQUARE FOOTAGE OF |
| | MITIGATION DUE FOR ALL TREES AND PALMS PROPOSED TO BE |
| | REMOVED ONCE CORRECTIONS HAVE BEEN MADE. APPLICANT HAS |
| | STATED THIS WILL BE PROVIDED IN A LATER |
| | SUPPLEMENT.CALCULATIONS MUST BE PROVIDED AFTER |
| | CORRECTIONS. |
| | |
| | 1.9. SATISFIED. TREE CANOPY AREA MEASUREMENT CHART ON |
| | SHEET L3.13 IS NOT CORRECT, VALUES SHOWN ARE FOR THE |
| | DMP OPEN SPACE CANOPY CREDITS. SEE CATEGORY LIST AND |
| | VALUES ABOVE. |
| | |
| | 1.10 SATISFIED. TOTAL REPLACEMENT CANOPY CREDITS BY |
| | CATEGORY WILL NEED TO BE CALCULATED BASED ON THE FINAL |
| | PLANT LIST TO SHOW THAT MITIGATION IS MET. |
| | |
| | 2. SATISFIED. SECTION 94-448 (D)(3) REQUIRES NATIVE |
| | TREES (AND PALMS) IN GOOD CONDITION TO BE PRESERVED ON |
| | SITE OR RELOCATED. PROVIDE AN ARBORIST REPORT FOR THE |
| | NATIVE TREES AND PALMS THAT ARE PROPOSED TO BE REMOVED |
| | DUE TO CONDITION OR UNABLE TO RELOCATE. |
| | |
| | 3. SATISFIED. LIGNUM VITAE IS A SMALL TREE AT THE NORTH |
| | EDGE OF ITS VIABLE RANGE, AND ORANGE GEIGER MAY NOT DO |
| | WELL IN THIS LOCATION. IT IS BETTER TO CHOOSE A MEDIUM |
| | NATIVE TREE SUCH AS SILVER BUTTONWOOD THAT WILL THRIVE |
| | AT THIS LOCATION. |
| | REDUCTION OF QUANTITIES IS NOTED. THIS LOCATION IS |
| | ADJACENT TO SALT WATER AND WILL BE SUBJECT TO HIGH WIND |
| | AND SALT SPRAY DURING WIND EVENTS SO IS NOT COMPARABLE |
| | TO PROTECTED LOCATIONS. |
| | |
| | 4. SATISFIED. FINAL SPECIES TREE COUNTS WILL NEED TO BE |
| | PROVIDED AND SUBSTITUTIONS CAN BE MADE LATER. |
| | |
| | 5. SATISFIED. IN A LANDSCAPE REQUIREMENT CHART, PROVIDE |
| | THE PERCENTAGE AND SQUARE FOOTAGE CALCULATIONS FOR: |
| | |
| | 5.1 TOTAL NON-BUILDING OPEN SPACE, MUST BE AT LEAST 50% |
| | |
| | 5.2 TOTAL IMPERVIOUS AREA, CANNOT EXCEED 75% |
| | |
| | 6. SATISFIED. USING THE 50% OPEN SPACE SQUARE FOOTAGE, |
| | CALCULATE THE REQUIRED TREES, FLOWERING TREES AND |
| | SHRUBS REQUIRED PER SECTION 94-442(C)(2)B. PROVIDE THE |
| | INFORMATION IN THE LANDSCAPE REQUIREMENT CHART. |
| | |
| | 7. SATISFIED. SECTION 94-443(C)(3) REQUIRES THAT A |
| | MINIMUM OF 75 PERCENT OF ALL TREES THAT ARE REQUIRED TO |
| | BE PLANTED WITHIN THE INTERIOR OF AN OFF-STREET PARKING |
| | AREA SHALL BE CATEGORY 1 SHADE TREES. PROVIDE THE |
| | CALCULATIONS IN A LANDSCAPE REQUIREMENT CHART. |
| | |
| | 8. SATISFIED. PROVIDE AN EXHIBIT SHOWING THE PARKING |
| | AREA SURFACE CALCULATIONS, PARKING SPACE AREAS AND |
| | LANDSCAPE AREAS PROVIDED TO DEMONSTRATE COMPLIANCE WITH |
| | SECTIONS 94-443 (C)(3) AND (4). PROVIDE THE |
| | CALCULATIONS IN A LANDSCAPE REQUIREMENT CHART. |
| | APPLICANT HAS STATED THIS WILL BE PROVIDED IN A LATER |
| | SUPPLEMENT. |
| | |
| | 9. SATISFIED. LOCATIONS OF SOME EXISTING UTILITIES ARE |
| | IN QUESTION. ONCE FINALIZED ON PLANS, TREE CONFLICTS |
| | MUST BE ADDRESSED. |
| | |
| | 10. SATISFIED. SEE COMMENT 6. 50% OPEN SPACE |
| | REQUIREMENT SQUARE FOOTAGE IS TO BE CALCULATED BASED ON |
| | THE ENTIRE SITE SQUARE FOOTAGE. |
| | |
| | 11. SATISFIED. CONSIDER SHIFTING TREES TO LOCATIONS TO |
| | ELIMINATE THE USE OF ANY ROOT BARRIERS REQUIRED TO |
| | PROTECT UTILITY LINES. THIS IS BETTER FOR THE TREES AND |
| | SAVES ON COST. |
| | |
| | 12. SATISFIED. COMPLETE THE FLORIDA FRIENDLY DESIGN |
| | OPTION LIST TO PROVIDE THE REQUIRED 50 POINTS. |
| | |
| | 13. SATISFIED. ARTIFICIAL TURF IS LIMITED TO THE |
| | LOCATIONS AS LISTED IN SECTION 94-451. THE CODE DOES |
| | NOT ALLOW FOR ARTIFICIAL TURF FOR CITY OWNED LOCATIONS. |
| | IF PARKS AND RECREATION DESIRES TO ALLOW IT IN PARK |
| | SETTINGS AND DESIRES TO AMEND THE CODE, STAFF NEEDS TO |
| | BE NOTIFIED OF THIS. ANY PROPOSED LOCATION NEEDS TO BE |
| | CLARIFIED, AS IT APPEARS THAT THE ARTIFICIAL TURF IN |
| | THE EXERCISE AREA HAS BEEN CHANGED TO RUBBERIZED |
| | SURFACE ON SHEET C-3.02. |
| | |
| | 14. SATISFIED. SHOW LIGHTING LOCATIONS ON THE LANDSCAPE |
| | PLAN AND RESOLVE CONFLICTS. |
| | |
| | 15. SATISFIED. SHEET L2.11 LANDSCAPE SPECIFICATIONS IS |
| | BLANK. |
| | |
| | 16. SATISFIED. PARKING AREA LOCATED ALONG THE NORTH |
| | PROPERTY LINE LACKS THE REQUIRED TERMINAL ISLAND SHADE |
| | TREES AT THE ENDS OF THE ROW OF 7 PARKING SPACES. |
| | SCREENING HEDGE IS ALSO LACKING ALONG THE WESTERNMOST |
| | SPACE. |
| | |
| | |
| | ADDITIONAL COMMENTS 9/20/22: |
| | |
| | 17. SATISFIED. TERMINAL ISLAND TREE MISSING AT SOUTH |
| | END OF ROW OF PARKING FOR THE SOUTH PARKING LOT. IF THE |
| | SILVER BUTTONWOOD IS INTENDED TO MEET THIS REQUIREMENT |
| | A LARGER SHADE TREE WOULD BE BETTER PLACED TO PROVIDE |
| | SHADE FOR THE PARKING. |
| | |
| | 18. SATISFIED ??? BOAT TRAILER PARKING ALONG NORTH |
| | PROPERTY LINE EXEMPTED, AS ONLY MODIFICATIONS MADE TO |
| | EXISTING CONFIGURATION. THERE ARE MORE THAN 10 SPACES |
| | IN A ROW OF THE REQUIRED PARKING SPACES IN THE NORTH |
| | PARKING LOT. SECTION 94-443(C)(3)B. REQUIRES AN |
| | INTERIOR LANDSCAPE ISLAND FOR EVERY 10 SPACES IN A ROW. |
| | AN ALTERNATIVE OPTION IS TO MEET THE REQUIREMENTS OF |
| | 94-443(C)(6) TO PROVIDE ADDITIONAL TREE CANOPY IN THE |
| | LANDSCAPE BUFFER. |
| | |
| | 19. SATISFIED. EXISTING PODOCARPUS HEDGE NEEDS TO BE |
| | SHOWN FOR THE EXISTING LIFT STATION SCREENING. |
| | |
| | 20. SATISFIED. ALL PROPOSED TREES MUST MEET THE MINIMUM |
| | 12 FT HEIGHT REQUIREMENT. |
| | |
| | |
| | |
| | |
| | *** CONDITIONS OF APPROVAL *** |
| | |
| | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON |
| | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE |
| | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT |
| | SERVICES DEPARTMENT, PLANNING DIVISION. |
| | |
| |
Print |