Plan Review Notes
Plan Review Notes For Project Z21100018
Project Number Z21100018
Review Stop TRAFFIC
Sequence Number 2
Notes
Date Text
2022-09-27 08:54:26Z21100018 - CURRIE PARK - R1- 2022-09-22
  
 TRAFFIC COMMENTS
  
 1) NOT SATISFIED. PROVIDE COUNTY TPS LETTER
  
 2) NOT SATISFIED. A COMPREHENSIVE TRAFFIC STUDY WILL BE
 REQUIRED. PLEASE SCHEDULE A METHODOLOGY MEETING WITH
 THE TRAFFIC ENGINEERING GROUP, PRIOR TO REVISING OR
 RESUBMITTING THE TRAFFIC STUDY
  
 3) NOT SATISFIED. IN THE TRIP GENERATION TABLE ADD THE
 CAF?? PAVILION AS A TRIP GENERATOR
  
 4) NOT SATISFIED. PROVIDE A FIGURE SHOWCASING
 DRIVEWAY(S) VOLUMES AND DIRECTIONAL SPLIT, BOTH INBOUND
 AND OUTBOUND
  
 5) NOT SATISFIED. PROVIDE EXISTING WEEKEND TRAFFIC
 COUNTS
  
 6) NOT SATISFIED. PROVIDE PROPOSED DEVELOPMENT SITE
 PLAN IN THE TRAFFIC STUDY
  
 7) A DETAILED INTERNAL CIRCULATION ANALYSIS SHOULD BE
 PROVIDED IN THE TRAFFIC STUDY
  
  
  
 SITE COMMENTS
  
 8) NOT SATISFIED. PROVIDE A CLEAN SITE PLAN, SHOWCASING
 ONLY TRANSPORTATION FEATURES (I.E. ROAD, CURB, GUTTER,
 SIDEWALK, DRIVEWAY, PAVEMENT MARKING, SIGNAGE, PATHWAY,
 WALKWAY, PEDESTRIAN CROSSING, LOADING ZONE,
 PICK-UP/DROP-OFF AREA) AND CORRESPONDING DIMENSIONS. A
 SPECIFIC AND SEPARATE SITE PLAN SHEET SHOULD BE
 PROVIDED TO FULFILL THIS COMMENT
  
 9) SATISFIED. PROVIDE TYPICAL PARKING STALL DIMENSIONS
 AND TYPOLOGY (I.E. NORMAL, COMPACT, TRAILER). MARK OR
 PROPERLY LABEL EACH OF THEM ON THE SITE PLAN
  
 10) PARTIALLY SATISFIED. ON THE SITE PLAN, PLEASE
 SHOWCASE BASIC CURB DETAILS (I.E. DRIVEWAY AND PARKING
 STALLS IF ANY) ON THE OPPOSITE SIDE OF THE ROADS
 SURROUNDING THE PROPOSED DEVELOPMENT. PARKING STALL
 MARKINGS ARE MISSING. PLEASE INCLUDE THEM IN THE
 PAVEMENT MARKING AND SIGNAGE PLAN.
  
 11) NOT SATISFIED. PROVIDE AUTOTURN ANALYSIS FOR
 GARBAGE TRUCK AND/OR SERVICE VEHICLES DRIVING IN AND
 OUT OF THE PROPOSED DEVELOPMENT WITH VEHICLE DYNAMIC
 ENVELOPES CLEARLY DEFINED. ALSO PROVIDE ANALYSIS FOR
 TYPICAL TRUCK WITH BOAT TRAILER. INSERT DESIGN VEHICLES
 DETAILS IN THE DRAWING. PLEASE PROVIDE DOCUMENT NAME
 AND SHEET NUMBER SHOWCASING THE ANALYSIS. LATEST
 ANALYSIS IS NOT PROPER, ENGINEERING SERVICES CAN
 PROVIDE A SAMPLE ANALYSIS FOR REFERENCE PURPOSES
  
 12) SATISFIED. IDENTIFY AND DESIGNATE AN EASILY
 ACCESSIBLE MICRO-MOBILITY STATION AREA (MINIMUM 8 X 20
 FEET) AND PROVIDE BASIC ELECTRIFICATION READINESS. FOR
 THE LATTER ITEM, MORE SPECIFICALLY: A CONDUIT (2???
 SCHEDULE 40 PVC) TO THE POWER SOURCE WITH AN ELECTRICAL
 PULL BOX (240V CIRCUIT).
  
 13) SATISFIED. PROVIDE PARKING TABLE SHOWCASING THE
 NUMBER OF DESIGNATED PARKING SPACES, INCLUSIVE OF ADA,
 SPECIALTY OR RESTRICTED SUCH AS TRAILERS, AND BICYCLE
 ONES. PLEASE PROVIDE DOCUMENT NAME AND SHEET NUMBER
 SHOWCASING SUCH TABLE
  
 14) PARTIALLY SATISFIED. PROVIDE AND INDICATE FREIGHT
 DELIVERY LOADING ZONE. PROVIDE DIMENSIONS IN THE
 TRANSPORTATION SPECIFIC SITE PLAN. NOTE: THE DESIGNATED
 AREA SHOULD BE STRICTLY FOR COMMERCIAL VEHICLES AND
 SHOULD BE MARKED AND SIGNED ACCORDINGLY
  
 15) SATISFIED. PROVIDE A SIDEWALK WITH 10 FEET MINIMUM
 WIDTH ALONG SITE FRONTAGE. IMPLEMENTATION OF A MULTIUSE
 PATHWAY, WITH DISTINCT BICYCLE LANES IS STRONGLY
 ENCOURAGED. PLEASE
  
 16) NOT SATISFIED. ARE THERE ANY DESIGNATED
 PICK-UP/DROP-OFF OR VALET AREAS? IF SO CLEARLY INDICATE
 THEM ON THE SITE PLAN. COMMENT IS REFERRING TO
 PASSENGER PICK-UP/DROP-OFF OPERATIONS, NOT COMMERCIAL
 LOADING/UNLOADING. IN CASE OF THE FORMER, A VALET
 OPERATIONAL ANALYSIS SHOULD BE PROVIDED
  
 17) SATISFIED. THERE IS A CONCEPT TO EXTEND NORTHWOOD
 RD TO FLAGLER, AND POTENTIALLY INSTALL A ROUNDABOUT IN
 LIEU OF AN INTERSECTION. PLEASE COORDINATE WITH
 PLANNING AND CRA ON THIS ITEM, AS IT MAY AFFECT THE
 LAYOUT OF THE PARKING AREA AND THE ALIGNMENT OF THE
 DRIVEWAYS.
  
 18) PROVIDE A PAVEMENT MARKING AND SIGNAGE PLAN. THIS
 SHOULD BE A SEPARATE SITE PLAN SHEET OR INCLUDED IN THE
 TRANSPORTATION SPECIFIC SITE PLAN
  
 19) PROVIDE A SEPARATED AND PROTECTED TWO-WAY BIKE LANE
 ALONG THE EASTERN SIDE OF FLAGLER DR ACCORDING TO THE
 CITY BICYCLE MASTERPLAN. THIS IS A MAJOR ITEM, PLEASE
 CONTACT ENGINEERING SERVICES FOR FURTHER DISCUSSION OR
 CLARIFICATIONS
  
 VALERIO ORICCHIO
 CITY TRANSPORTATION ENGINEER
 561-494-1092
 [email protected]
  
  Print


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved