| Date |
Text |
| 2022-10-03 09:49:17 | FROM: RAY CARANCI, SENIOR LANDSCAPE PLANNER |
| | 561-822-1462 |
| | PROJECT: NORTHWOOD ANCHOR SITE DSI Z21080015 |
| | SEPTEMBER 30, 2022 |
| | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND |
| | PROVIDE THE FOLLOWING COMMENTS: |
| | |
| | |
| | 1. SATISFIED. SECTION 94-448 (D)(3) REQUIRES NATIVE |
| | TREES AND PALMS IN GOOD CONDITION TO BE PRESERVED ON |
| | SITE OR RELOCATED. ANSI A 300 (PART 5) STANDARDS |
| | SPECIFY EXAMPLES OF SUITABILITY RATINGS OF GOOD, |
| | MODERATE, OR POOR FOR RELOCATION. PROVIDE AN ARBORISTS |
| | REPORT RATING THE CONDITION AND RELOCATION POTENTIAL |
| | FOR THE NATIVE TREES AND PALMS. THERE ARE LIVE OAKS, |
| | SABAL PALMS, AND ROYAL PALMS THAT ARE INDICATED TO BE |
| | REMOVED. NON NATIVE TREES AND PALMS ARE NOT REQUIRED TO |
| | BE RELOCATED. |
| | 2. MAKE THE FOLLOWING CORRECTIONS TO THE TREE |
| | DISPOSITION LIST: |
| | ??? SATISFIED. THERE ARE MULTIPLE TREES AND PALMS THAT |
| | ARE MISIDENTIFIED ON THE TREE DISPOSITION LIST. |
| | ??? SATISFIED. ONLY TREES PROPOSED TO BE REMOVED WITH A |
| | CANOPY DIAMETER OF 20 FEET OR MORE SHOULD HAVE THE |
| | MITIGATION SQUARE FOOTAGE CALCULATED BASED ON THE |
| | ACTUAL DIAMETER. TREES LESS THAN 20 FEET CANOPY |
| | DIAMETER AND PALMS SHOULD SHOW THE CATEGORY MITIGATION |
| | DUE. |
| | SHOW THE MITIGATION SQUARE FOOTAGE DUE FOR PALMS BY |
| | CATEGORY (CATEGORY 3 IS 100 SQ FT, CATEGORY 4 IS 50 SQ |
| | FT.) |
| | ??? SATISFIED. MULTIPLE PALMS PLANTED TOGETHER MUST |
| | HAVE EACH SINGLE TRUNK COUNTED TOWARD MITIGATION. |
| | EXAMPLE: TRIPLE ADONIDIA WOULD BE 3 X 50 SQ FT. |
| | ??? SATISFIED. PROVIDE THE TOTAL MITIGATION SQUARE |
| | FOOTAGE DUE. |
| | PROVIDE THE TOTAL MITIGATION SQUARE FOOTAGE DUE. |
| | ??? SATISFIED. PROVIDE THE MITIGATION SQUARE FOOTAGE |
| | PROVIDED BASED ON THE PLANT LIST. |
| | |
| | 3. SATISFIED. PROVIDE A DIAGRAM OF THE REQUIRED AND |
| | PROVIDED PUBLIC, SEMI-PUBLIC, PRIVATE OPEN AREAS AND |
| | URBAN GREENWAYS SYSTEM FOR EACH PARCEL IN THE NMUD |
| | ZONING DISTRICT. IDENTIFY THE TYPE OF OPEN SPACE. 10% |
| | COMMON PRIVATE OPEN SPACE IS REQUIRED. |
| | THE REQUIRED OPEN SPACE NEEDS TO BE QUANTIFIED, |
| | IDENTIFIED AS TO THE TYPE, AND ALL REQUIREMENTS NEED TO |
| | BE SHOWN FOR THAT OPEN SPACE TYPE. |
| | SURFACE PARKING AREAS CANNOT BE COUNTED TOWARD REQUIRED |
| | OPEN SPACE. |
| | 4/13/22 SHEET A103.0 COULD NOT BE LOCATED IN THE |
| | SUBMITTAL. SHEET L102 SHOWS SURFACE PARKING AREA |
| | COUNTED AS LANDSCAPE OPEN SPACE. |
| | |
| | 4. SATISFIED. SHOW THE ROOFTOP TERRACES AND INCLUDE HOW |
| | THE REQUIREMENTS OF SECTION 94-210 P. 5. ARE MET, |
| | INCLUDING 15% LANDSCAPE REQUIREMENT AND PROVIDE A |
| | LANDSCAPE PLAN FOR EACH AREA. |
| | |
| | 5. SATISFIED. IDENTIFY RELOCATED TREES OR PALMS ON THE |
| | PLANT LIST AND COUNT THEM TOWARD THE REQUIRED TREES. |
| | |
| | 6. SATISFIED. IF ANY ARTIFICIAL TURF AREAS ARE |
| | PROPOSED, THEY MUST MEET THE REQUIREMENTS OF SECTION |
| | 94-451, INCLUDING ALL AREAS THAT ARE ALLOWED BY CODE |
| | MUST NOT BE VISIBLE FROM A ROAD OR STREET. |
| | |
| | 7. SATISFIED. BUFFER TREES AND HEDGES MUST BE PROVIDED |
| | ALONG ALL BUFFERS. THERE IS A LARGE GAP IN THE TREES |
| | ADJACENT TO THE WEST OF THE SURFACE PARKING LOT. THE |
| | WEST PROPERTY LINE ADJACENT TO THE FEC RAILROAD RIGHT |
| | OF WAY REQUIRES AT LEAST A 5 FOOT BUFFER STRIP PER |
| | SECTION 94-209 2. F. 1. E. |
| | |
| | THE BUFFER ON THE SOUTH SIDE OF THE SURFACE PARKING LOT |
| | DOES NOT MEET THE REQUIRED WIDTH. |
| | |
| | 8. SATISFIED. PROVIDE CALCULATIONS FOR REQUIRED STREET |
| | TREES AT MAXIMUM SPACING EVERY 30 FEET OR PORTION |
| | THEREOF AND SHOW THE NUMBER PROVIDED FOR EACH |
| | STREETSCAPE LENGTH. SHOW THE REQUIRED PLANTING STRIP. |
| | |
| | 4/13/22 EACH BLOCK STREET SEGMENT MUST BE LISTED WITH |
| | THE TOTAL LENGTH OF THE ADJACENT PROPERTY LINE AND THE |
| | REQUIRED AND PROVIDED STREET TREES SHOWN. CANNOT |
| | COMBINE SEGMENTS. THE NUMBER IN SOME SEGMENTS DOES NOT |
| | MEET CODE. THE OVERALL INTENT IS TO PROVIDE MAXIMUM |
| | TREE CANOPY COVERAGE FOR ALL SEGMENTS. |
| | |
| | 6/27/22 THE AREA ALONG 25TH STREET SHOWS A LONG GAP |
| | BETWEEN TREES WITH UTILITY VALVES AND FIRE HYDRANT. |
| | THIS NEEDS TO BE SPREAD OUT TO ALLOW TREES TO BE IN |
| | BETWEEN VALVES. |
| | STREET TREES ARE NOT SHOWN ON THE NORTHWOOD ROAD |
| | SEGMENT. |
| | |
| | 9. SATISFIED. CORRECT THE CODE REQUIREMENTS CHART ON |
| | SHEET L1.01TO UPDATE THE SHADE AND FLOWERING TREE |
| | REQUIREMENTS OF SECTION 94-442 C. 2. B. TO CURRENT |
| | CODE. |
| | |
| | |
| | 10. SATISFIED. REMOVED FROM PLAN. CORRECT THE CODE |
| | REQUIREMENTS CHART ON SHEET L1.01TO UPDATE THE SHADE |
| | AND FLOWERING TREE REQUIREMENTS OF SECTION 94-443 C. 3. |
| | TO CURRENT CODE. THE TREE PER 100 SQ FT REQUIREMENT WAS |
| | REMOVED. |
| | 4/13/22 THERE ARE 4 TERMINAL ISLANDS REQUIRED FOR THE |
| | SURFACE PARKING AREA, CORRECT ON CHART. |
| | |
| | 11. SATISFIED. AUSTRALIAN TREE FERN DOES NOT MEET THE |
| | DEFINITION OF TREE. |
| | |
| | 12. SATISFIED. SHOW ALL EXISTING AND PROPOSED WATER AND |
| | SEWER AND DRAINAGE LINES ON THE LANDSCAPE PLAN. SHOW |
| | LOCATIONS OF BACKFLOWS AND ADJUST LOCATIONS OF UTILITY |
| | LINES TO RESOLVE CONFLICTS WITH EXISTING AND PROPOSED |
| | TREES AND LANDSCAPING. |
| | |
| | FDC CONNECTIONS SHOULD BE MOVED TO THE BUILDING AND NOT |
| | BE IN THE STREETSCAPE. |
| | EXFILTRATION TRENCHES CANNOT BE LOCATED IN THE |
| | STREETSCAPE AS THEY WILL RESTRICT THE ROOT SPACE |
| | AVAILABLE FOR THE STREET TREES. |
| | |
| | 6/27/22 THERE ARE STILL CONFLICTS BETWEEN WATER, FIRE |
| | AND SEWER LINES IN THE STREETSCAPE AND THE PLAZA IV |
| | OPEN SPACE. |
| | |
| | 13. SATISFIED. PLANT LIST NEEDS TO BE MODIFIED TO |
| | SEPARATE THE REQUIRED OPEN SPACE PLANT LISTS. |
| | |
| | |
| | 14. SATISFIED. PROVIDE THE 50 REQUIRED FLORIDA FRIENDLY |
| | POINTS BASED ON THE FINAL PLANT LIST PER SECTION |
| | 94-443(G). AFTER MAKING THE FOLLOWING CORRECTIONS: |
| | ??? 2 INDICATE WHERE THE AREAS ARE DESIGNATED. |
| | ??? 3A AND 3C ARE NOT SUPPORTED BY THE PLANT LIST. |
| | ??? 5B AND 5D ADD UP TO MORE THAN 100%, MUST REDUCE ONE |
| | CATEGORY |
| | ??? 6B IS NOT SUPPORTED BY THE PLAN SUBMITTED |
| | |
| | |
| | 15. SATISFIED. SHOW COMPLIANCE WITH SECTION 94-445 L. |
| | PLANT SPECIES. A MINIMUM OF 60 PERCENT OF PLANT |
| | MATERIAL ADDED SHALL BE FLORIDA NATIVE OR DROUGHT |
| | TOLERANT SPECIES SELECTED FROM THE CITY LIST OR THE |
| | LIST OF SPECIES IN THE MOST RECENT EDITION OF SOUTH |
| | FLORIDA WATER MANAGEMENT DISTRICT WATERWISE SOUTH |
| | FLORIDA LANDSCAPES. PROVIDE THE ACTUAL PERCENTAGE BASED |
| | ON THE PLANT LIST. |
| | |
| | |
| | 16. SATISFIED. REMOVED FROM PLAN. ALL SURFACE PARKING |
| | MUST MEET THE REQUIREMENTS OF SECTION 94-443(C)(3) A. |
| | INCLUDING TERMINAL LANDSCAPE ISLANDS, INTERIOR ISLANDS |
| | AND SHADE TREES. |
| | MINIMUM BUFFER WIDTH IS NOT MET. |
| | 17. SATISFIED. REMOVED FROM PLAN. PROVIDE AN EXHIBIT |
| | SHOWING THE PARKING AREA SURFACE CALCULATIONS, PARKING |
| | SPACE AREAS AND LANDSCAPE AREAS PROVIDED TO DEMONSTRATE |
| | COMPLIANCE WITH SECTIONS 94-443 (C)(3) AND (4). PROVIDE |
| | THE CALCULATIONS IN THE LANDSCAPE REQUIREMENT CHART. |
| | REFER TO FIGURE XIV-1. SHOW THE ACTUAL PROVIDED |
| | LANDSCAPE SQUARE FOOTAGE. |
| | SEE THE REFERENCED FIGURE TO PROVIDE THE EXHIBIT AND |
| | CORRECT CALCULATIONS. |
| | |
| | 18. SATISFIED. PROVIDE SCREENING HEDGES AND SHOW |
| | LOCATIONS FOR ALL GROUND MOUNTED VALVES AND EQUIPMENT |
| | AND ADD A NOTE THAT ALL EQUIPMENT WILL BE SCREENED. |
| | |
| | 19. NOT SATISFIED. PORTIONS OF THE RIGHT OF WAY ON |
| | BROADWAY AND 24TH STREET ARE FDOT RIGHT OF WAY AND ARE |
| | SUBJECT TO REVIEW AND PERMITTING BY FDOT. PROVIDE |
| | PRELIMINARY REVIEW OF ANY STREETSCAPE PROPOSED WITHIN |
| | THE FDOT RIGHT OF WAY. |
| | |
| | 4/13/22 THIS COMMENT WAS NOT ADDRESSED IN THE RESPONSES |
| | AS DISCUSSED AT THE PPRC MEETING. |
| | 8/4/22 RESPONSES WERE NOT SHOWN ON THE SUBMITTED |
| | MATERIAL. |
| | 9/30/22 PRELIMINARY LETTER NEEDS TO BE SUBMITTED. |
| | |
| | ADDITIONAL COMMENTS 4/13/22: |
| | 20. SATISFIED. STREET TREES MUST MEET THE MINIMUM CODE |
| | REQUIREMENT OF 20 FEET ALONG MAIN ROADS, BUT ALL MUST |
| | BE OF SUFFICIENT HEIGHT TO PROVIDE SAFE SIGHTLINES AND |
| | TRAFFIC CLEARANCE FOR PEDESTRIANS AND VEHICLES. |
| | CATHEDRAL LIVE OAKS MUST BE LISTED AT 20 FEET MINIMUM. |
| | |
| | 21. SATISFIED. STAFF PREFERS THAT THE GUMBO LIMBO |
| | STREET TREES BE CHANGED TO GREEN BUTTONWOOD DUE TO ROOT |
| | ISSUES IN CONFINED AREAS. |
| | |
| | ADDITIONAL COMMENTS 6/27/22: |
| | 22. SATISFIED. RESPONSES TO LANDSCAPE COMMENTS WERE NOT |
| | FOUND IN THE RESPONSE MEMO. |
| | |
| | 23. SATISFIED. SHOW LOCATIONS AND PROVIDE A DETAIL FOR |
| | STRUCTURAL SOIL UNDER THE SIDEWALK/HARDSCAPE AREAS |
| | ADJACENT TO THE STREET TREES. THIS SHOULD BE A 9 X 14 |
| | FT AREA FOR EACH TREE ADJACENT TO THE CURB THAT WOULD |
| | BE PLANTING AREA AND STRUCTURAL SOIL. |
| | |
| | ADDITIONAL COMMENTS 9/30/22: |
| | |
| | 24. A CODE AMENDMENT IS PENDING REGARDING THE |
| | REQUIREMENTS FOR PUBLIC OPEN SPACE. IF THE AMENDMENT IS |
| | APPROVED, STAFF WILL NEED TO REVIEW THE PUBLIC OPEN |
| | SPACE FOR COMPLIANCE WITH THE NEW CODE. |
| | |
| | CONDITIONS OF APPROVAL |
| | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON |
| | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE |
| | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT |
| | SERVICES DEPARTMENT, PLANNING DIVISION. |
| | 2. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE |
| | RESPONSIBLE FOR THE PERMITTING AND INSTALLATION OF THE |
| | STREET TREES AND RIGHT OF WAY LANDSCAPING AND |
| | IRRIGATION APPROVED WITH THIS PETITION. |
| | 3. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE |
| | RESPONSIBLE FOR THE MAINTENANCE OF THE ROAD RIGHT OF |
| | WAY LANDSCAPING AND IRRIGATION. THIS WILL BE THROUGH A |
| | SEPARATE MAINTENANCE AGREEMENT WITH THE CITY. |
| | |
| | |
| | |
| | PROJECT: NORTHWOOD ANCHOR SITE ROW ABANDONMENT |
| | Z21100023 |
| | NO COMMENTS AT THIS TIME. |
| | |
| | |
| | PROJECT: NORTHWOOD ANCHOR SITE VARIANCES Z21080018 |
| | NO COMMENTS AT THIS TIME. |
| | |
| |
Print |