| 2022-04-14 11:06:18 | CASE NO. 1895 - FEBRUARY 2022 RESUBMITTAL |
| | NORTHWOOD COMMONS - NMUD ANCHOR SITE |
| | BROADWAY & 24TH STREET |
| | |
| | - CONTACT ERIC SCHNEIDER @ (561) 822-1446, |
| | [email protected] |
| | |
| | - PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN |
| | WRITTEN FORMAT. |
| | |
| | - WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF FOUR |
| | (4) PAPER COPIES AND AN ELECTRONIC COPY IN .PNG FORMAT |
| | OF ALL PLANS. PLEASE NOTE THAT CHANGES ON THE |
| | RESUBMITTED PLANS OR THE SUBMITTAL OF INFORMATION/PLANS |
| | TO ADDRESS THE COMMENTS MAY RESULT IN ADDITIONAL |
| | COMMENTS. |
| | |
| | - THE PPRC COMMENTS SHALL BE SUFFICIENTLY ADDRESSED AND |
| | SUBMITTED TO THE PLANNING DIVISION BY 5 PM ON FRIDAY, |
| | APRIL 29, 2022, TO BE ELIGIBLE TO BE SCHEDULED FOR THE |
| | JUNE 21, 2022 PLANNING BOARD MEETING. |
| | |
| | - PLEASE NOTE THAT IF THE PLANNING DIVISION HAS NOT |
| | RECEIVED A RESPONSE TO THE PPRC COMMENTS WITHIN 60 DAYS |
| | FROM THE DATE OF THE PPRC MEETING (BY JUNE 14, 2022), |
| | THE PLANNING DIVISION MAY NOTIFY THE APPLICANT THAT THE |
| | CASE IS CONSIDERED WITHDRAWN. ANY FURTHER ACTION SHALL |
| | REQUIRE A NEW DEVELOPMENT APPLICATION. |
| | |
| | - PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1) |
| | RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY ISSUED |
| | COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE |
| | APPLICANT WILL BE ASSESSED A RESUBMITTAL FEE. SUCH FEE |
| | WILL BE 20% OF THE ORIGINAL APPLICATION FEE ($600). |
| | |
| | - PUBLIC HEARING NOTIFICATION SIGNAGE SHALL BE POSTED |
| | IN ACCORDANCE WITH THE REQUIREMENTS OF SECTION |
| | 94-39(I)(5) OF THE ZONING AND LAND DEVELOPMENT |
| | REGULATIONS. |
| | |
| | THE DSI RESUBMITTAL COINCIDES WITH A CODE TEXT CHANGE |
| | TO THE NMUD DEVELOPMENT REGULATIONS. STAFF HAS REVIEWED |
| | THE SUBMITTED PLANS FOR COMPLIANCE WITH BOTH THE |
| | EXISTING REGULATIONS AND THE PROPOSED TEXT CHANGES, |
| | WHERE APPLICABLE. THE APPLICANT?S STATED GOAL WAS TO |
| | AMEND THE DEVELOPMENT REGULATIONS TO REFLECT THE DESIGN |
| | OF THE PLAN WHERE IT COULD NOT COMPLY WITH THE |
| | REGULATIONS AND THUS AVOID VARIANCES/WAIVERS AT THE |
| | ZONING BOARD OF APPEALS. THE SUBMITTED CODE REVISIONS |
| | DO NOT COVER ALL OF THE AREAS WHERE THE PLAN DOES NOT |
| | COMPLY WITH THE CODE. STAFF HAS IDENTIFIED THESE |
| | DISCREPANCIES. FOR BOTH THE APPLICANT PROPOSED AND THE |
| | STAFF IDENTIFIED DISCREPANCIES, STAFF HAS INCLUDED IF |
| | STAFF WILL SUPPORT A CODE CHANGE OR NOT. NOTE: THE CODE |
| | REVISION CASE INCLUDES COMMENTS RELATED TO THE PROPOSED |
| | CODE CHANGES THAT DO NOT DIRECTLY IMPACT THE SITE PLAN. |
| | |
| | 1) REPEAT COMMENT: PROVIDE A TRAFFIC PERFORMANCE |
| | STANDARDS APPROVAL LETTER FROM THE PALM BEACH COUNTY |
| | TRAFFIC DIVISION FOR THE FULL SCOPE OF THE PROPOSED |
| | DEVELOPMENT. *** THIS IS REQUIRED PRIOR TO SCHEDULING A |
| | PLANNING BOARD HEARING. |
| | |
| | 2) UPDATED COMMENT: THE NON-RESIDENTIAL SQUARE FOOTAGE |
| | LISTED IN THE TRAFFIC IMPACT ANALYSIS DOES NOT MATCH |
| | THE SITE DATA ON THE PLANS. THE TRAFFIC IMPACT ANALYSIS |
| | MUST REFLECT THE FULL SCOPE OF THE DEVELOPMENT. |
| | |
| | 3) REPEAT COMMENT: PROVIDE A PREDETERMINATION LETTER |
| | FROM FDOT FOR THE IMPROVEMENTS WITHIN THE FDOT |
| | RIGHTS-OF-WAY OF BROADWAY AND 24TH AND 25TH STREETS |
| | ADJACENT TO THE PROJECT. *** THIS IS REQUIRED PRIOR TO |
| | SCHEDULING A PLANNING BOARD HEARING. |
| | |
| | 4) REPEAT COMMENT: SECTION 94-209.J.1.C REQUIRES THAT |
| | PROJECTS WITH THREE OR MORE DISTINCTLY SEPARATE |
| | BUILDINGS HAVE SUBSTANTIALLY DIFFERENT FRONT |
| | ELEVATIONS. SUBSTANTIALLY DIFFERENT FRONT ELEVATIONS |
| | SHALL INCLUDE BUT NOT BE LIMITED TO VARIATIONS IN |
| | FENESTRATION, MATERIAL, MASSING AND COLOR. BUILDINGS B |
| | AND C DO NOT HAVE SUBSTANTIALLY DIFFERENT FRONT |
| | ELEVATIONS FROM EACH OTHER IN ACCORDANCE WITH THE CODE |
| | REQUIREMENTS. |
| | |
| | 5) THE MAXIMUM GROUND FLOOR STORY HEIGHT IN NMUD IS 20 |
| | FEET. THE RETAIL AREAS ON THE NORTHEAST PORTION OF |
| | BUILDING A ARE SHOWN AT 26 FEET, WHICH DOES NOT COMPLY. |
| | THE STORY HEIGHT LIMITATION WILL NEED TO BE REMOVED AS |
| | AN NMUD CORE SUBAREA REQUIREMENT. STAFF DOES NOT OBJECT |
| | TO THIS ADDED CHANGE. |
| | |
| | 6) THE MAXIMUM STORY HEIGHT ABOVE THE GROUND FLOOR IN |
| | NMUD IS 12 FEET. PLEASE EXPLAIN THE 13-FOOT 4-INCH |
| | LEVEL SHOWN ON THE ELEVATIONS (LEVEL 3.5) FOR BUILDING |
| | A. IF IT IS IN EXCESS OF 12 FEET, IT DOES NOT COMPLY. |
| | THE STORY HEIGHT LIMITATION WILL NEED TO BE REMOVED AS |
| | AN NMUD CORE SUBAREA REQUIREMENT. STAFF DOES NOT OBJECT |
| | TO THIS ADDED CHANGE. |
| | |
| | 7) BUILDING A: THE BUILDING HEIGHT PERMITTED WITHIN THE |
| | AREA SOUTH OF CORE PARCEL B IS 56 FEET. THE UNITS ON |
| | THE SOUTH END OF THE BUILDING, EAST OF PINEWOOD, |
| | STARTING AT RESIDENCE LEVEL 4 EXCEED THE PERMITTED. |
| | STAFF HAS NOTED THAT THE APPLICANT HAS SUBMITTED A CODE |
| | CHANGE TO MOVE THIS LINE; HOWEVER, STAFF DOES NOT |
| | SUPPORT THIS PROPOSED CHANGE. A SOLUTION IS TO MOVE |
| | THIS LEG OF THE TOWER NORTH, PREFERABLY TO ALIGN WITH |
| | 24TH STREET TO PROVIDE A TERMINAL VISTA. THE SOUTH |
| | BOUNDARY OF CORE PARCEL B WAS SPECIFICALLY SET AT THIS |
| | LOCATION TO PROVIDE A TRANSITION TO THE NORTHWOOD ROAD |
| | HISTORIC DISTRICT. NOTE: SINCE PINEWOOD IS BEING |
| | ABANDONED, THE AREA OF THE ABANDONED ROADWAY NEEDS TO |
| | BE ASSIGNED A BUILDING HEIGHT DESIGNATION. STAFF DOES |
| | NOT OBJECT TO THE PARCEL A HEIGHT LINE MOVING EAST TO |
| | COVER THE ABANDONED PORTION OF PINEWOOD. |
| | |
| | 8) BUILDING B: THE PORTION OF THE BUILDING WITHIN THE |
| | NORTHWOOD ROAD HISTORIC DISTRICT CONTINUES TO BE SHOWN |
| | IN PLAN AND ELEVATION (SHEET A404) EXCEEDING THE |
| | PERMITTED NUMBER OF STORIES AND BUILDING HEIGHT (3 |
| | STORIES/44 FEET). NOTE: THE BUILDING IS CORRECTLY SHOWN |
| | ON SHEET A113. ALL DRAWINGS MUST SHOW CONSISTENT, CODE |
| | COMPLIANT CONDITIONS. |
| | |
| | 9) BUILDING C: THERE IS A DISCREPANCY WITH BUILDING C |
| | IN PLAN AND IN ELEVATION. THE PLAN VIEW SHOWS THAT THE |
| | 4TH STORY IS LOCATED ON THE NORTH SIDE OF THE ALLEY AND |
| | THUS OUTSIDE OF THE NORTHWOOD ROAD HISTORIC DISTRICT |
| | BOUNDARY. HOWEVER, THE ELEVATION VIEW ON SHEET A405 |
| | SHOWS THE 4TH STORY EXTENDING INTO THE NORTHWOOD ROAD |
| | HISTORIC DISTRICT, WHERE ONLY A 3-STORY BUILDING IS |
| | PERMITTED. ALL DRAWINGS MUST SHOW CONSISTENT, CODE |
| | COMPLIANT CONDITIONS. |
| | |
| | 10) PROVIDE THE SQUARE FOOTAGE FOR THE UNITS IN |
| | BUILDING B SO THAT STAFF CAN VERIFY THAT THE MINIMUM |
| | UNIT SIZE IS ACHIEVED. |
| | |
| | 11) BUILDING B SHOWS FOUR 1,200 SF TOWNHOUSES. THIS |
| | UNIT'S SIZE/TYPE IS NOT LISTED ON THE UNIT MATRIX |
| | BREAKDOWN. |
| | |
| | 12) BUILDING B IS NOT SHOWN IN THE SAME LOCATION IN |
| | RELATIONSHIP TO THE WEST PROPERTY LINE ON SHEETS A113 |
| | (ZERO FEET), A404 (5 FEET) AND A301 (10 FEET). ALL |
| | DRAWINGS MUST SHOW CONSISTENT, CODE COMPLIANT |
| | CONDITIONS. |
| | |
| | 13) THE WEST PROPERTY LINES DO NOT OVERLY THE SAME ON |
| | SHEET A301. THIS LEADS TO INCORRECT SETBACK DIMENSIONS. |
| | ADDITIONALLY, THE DIMENSION MUST BE FROM THE FURTHEST |
| | PROJECTION. THE SUPPORT COLUMNS ARE SHOWN ENCROACHING |
| | INTO THE REQUIRED 5-FOOT LANDSCAPE BUFFER. |
| | |
| | 14) PROVIDE THE ROOF PLAN FOR THE TOWER PORTION OF |
| | BUILDING A. |
| | |
| | 15) PROVIDE THE HEIGHTS OF THE ROOFTOP MECHANICAL |
| | EQUIPMENT AND THE MECHANICAL EQUIPMENT SCREENING |
| | HEIGHTS FOR ALL THREE BUILDINGS SO THAT STAFF CAN |
| | VERIFY THAT THE EQUIPMENT IS SCREENED IN ACCORDANCE |
| | WITH THE NMUD REQUIREMENTS. |
| | |
| | 16) PROVIDE THE VISIBILITY TRIANGLE INFORMATION SO |
| | STAFF CAN VERIFY COMPLIANCE WITH CODE FOR ALL CORNERS, |
| | INCLUDING THE BROADWAY EXTENSION, THE ALLEY BETWEEN |
| | BUILDING C, THE GARAGE RAMP AT 25TH STREET, AND THE NW |
| | CORNER OF PINEWOOD AND NORTHWOOD ROAD. |
| | |
| | 17) THE MAXIMUM LOT WIDTH FOR FLEX BUILDINGS IS 200 |
| | FEET. THE LOT CONTAINING BUILDING B IS 231 FEET LONG. |
| | |
| | 18) THE TOWER IS SHOWN ENCROACHING THE BROADWAY TOWER |
| | SETBACK FROM THE PODIUM. THE 15-FOOT SETBACK LINE |
| | DIMENSION TAG DOES NOT MATCH BLUE SETBACK LINE NOR DOES |
| | IT SCALE TO 15 FEET. THE LINE SCALES TO 15 FEET. |
| | |
| | 19) SHEET A0.02 LISTS THE GROSS LAND AREA AS 144,250 |
| | SQUARE FEET. SHEET L1.01 LISTS THE SITE AS HAVING |
| | 88,595 SQUARE FEET, WHICH IS NOT THE AREA COVERED BY |
| | BUILDING A. ALL PLANS MUST INCLUDE THE CORRECT AMOUNT |
| | OF AREA. EACH DEVELOPMENT PARCEL, BUILDING A, B AND C, |
| | MUST BE BROKEN DOWN SEPARATELY (INCLUDING THE ABANDONED |
| | RIGHTS-OF-WAY) AND SHOW COMPLIANCE WITH THE PERVIOUS |
| | AND IMPERVIOUS REQUIREMENTS. NOTE: THE LISTED 12,630 |
| | SQUARE FEET OF PERVIOUS AREA WOULD NOT MEET THE MINIMUM |
| | PERVIOUS AREA REQUIRED BY THE NMUD REGULATIONS, EITHER |
| | INDIVIDUALLY OR COLLECTIVELY. |
| | |
| | 20) THE SETBACKS AND BUILDING FRONTAGE ALONG 23RD |
| | STREET AND THE REMAINING SECTION OF PINEWOOD FOR |
| | BUILDING A ARE NOT MET. |
| | |
| | 21) THE NMUD REGULATIONS REQUIRE THAT THE PRIMARY |
| | ENTRANCE TO THE UPPER LEVELS OF A MIXED-USE BUILDING |
| | SHALL BE FROM A PUBLIC RIGHT-OF-WAY. WHERE IS THE |
| | PRIMARY ENTRANCE TO THE UPPER LEVELS OF BUILDING A? IT |
| | APPEARS THAT IT IS EITHER THE NORTH OR SOUTH LOBBY, |
| | NEITHER OF WHICH ACCESS A PUBLIC RIGHT-OF-WAY. PUTTING |
| | THESE LOBBY ENTRANCES ADJACENT TO THE LOADING DOCKS AND |
| | INTERNAL TO THE BUILDING DOES NOT PROVIDE AN |
| | ATTRACTIVE, ACTIVE STREET PRESENCE FOR THE RESIDENTIAL |
| | TOWER. THE MAIN ENTRANCE SHOULD BE PROMINENTLY ON |
| | BROADWAY OR NORTHWOOD ROAD. |
| | |
| | 22) THE NMUD REGULATIONS REQUIRE THAT THE PRIMARY |
| | ENTRANCE TO THE UPPER LEVELS OF A MIXED-USE BUILDING |
| | SHALL BE FROM A PUBLIC RIGHT-OF-WAY. THE PRIMARY |
| | ENTRANCE TO THE UPPER LEVELS OF BUILDING B IS SHOWN |
| | FROM THE PRIVATE RIGHT-OF-WAY EXTENSION OF BROADWAY. |
| | |
| | 23) BUILDING C IS A FLEX BUILDING. TABLE VII-7 REQUIRES |
| | THAT FLEX BUILDING THAT ABUTS A 15-FOOT WIDE ALLEY HAVE |
| | A 15-FOOT SETBACK FROM THE EDGE OF THE ALLEY. BUILDING |
| | C DOES NOT MEET THIS REQUIREMENT. STAFF IS NOT PREPARED |
| | TO SUPPORT CHANGES TO THE SETBACK REQUIREMENTS OUTSIDE |
| | OF THE CORE SUB-DISTRICT SINCE THIS WILL AFFECT |
| | PROPERTIES THROUGHOUT NMUD. |
| | |
| | 24) THE NMUD REGULATIONS CURRENTLY LIMIT THE TOWER |
| | FLOOR PLATE TO 30,000 SQUARE FEET FOR ANY SINGLE |
| | FLOORPLATE WITH AND AVERAGE FLOORPLATE OF UP TO 20,000 |
| | SQUARE FEET. THE TEXT AMENDMENT IS REQUESTING THAT THE |
| | MAXIMUM FLOORPLATE CAN BE UP TO 50,000 SQUARE FEET. |
| | PLEASE PROVIDE VERIFICATION THAT THE AVERAGE TOWER |
| | FLOORPLATE IS 20,000 SQUARE FEET OR LESS. |
| | |
| | DESIGN STANDARDS |
| | |
| | 25) REPEAT COMMENT: NO INFORMATION WAS PROVIDED TO |
| | VERIFY THE ACTIVE USE STANDARDS, THE FACADE |
| | ARTICULATION REQUIREMENTS, THE ARCHITECTURAL TREATMENT |
| | STANDARDS OR THE FENESTRATION STANDARDS THAT ARE |
| | REQUIRED BY THE NMUD REGULATIONS. THIS SHALL BE |
| | PROVIDED IN TABULAR FORM AND SHOWN ON THE ELEVATION |
| | DRAWINGS. |
| | |
| | 26) STAFF WILL NOT SUPPORT THE AMENDMENT THAT WILL |
| | PERMIT THE BUILDING THAT IS ALMOST 400 FEET IN LENGTH |
| | ALONG BROADWAY AND 350 FEET IN LENGTH ALONG 25TH STREET |
| | WITHOUT THE INCLUSION OF PLANAR BREAKS. |
| | |
| | 27) PROVIDE THE DIMENSIONS OF THE PROJECTIONS AND |
| | ENCROACHMENTS (EX. BALCONIES AND OTHER ARCHITECTURAL |
| | FEATURES) ON THE PLANS AND ELEVATIONS SO THAT STAFF CAN |
| | VERIFY COMPLIANCE WITH THE NMUD REGULATIONS. |
| | |
| | 28) THE ROOF OF THE PASEO IS NOT RENDERED CORRECTLY. |
| | THE SITE AND LANDSCAPE PLANS DO NOT SHOW HOLES IN THE |
| | PARKING DECK THAT ARE ACCENTUATED WITH LANDSCAPE. |
| | ADDITIONALLY, THE GRADE LEVEL LANDSCAPE THAT HAS BEEN |
| | ADDED DOES NOT MATCH THE LANDSCAPE PLAN. YOU MAY NOT |
| | PROVIDE INACCURATE RENDERINGS THAT MAKE THE FINAL |
| | PRODUCT LOOK DIFFERENT THAN WHAT YOU ARE SHOWING IN THE |
| | PLANS. |
| | |
| | STREETSCAPE |
| | |
| | 29) REPEAT COMMENT: NO DETAILS WERE PROVIDED ON THE |
| | SITE LIGHTING TO VERIFY COMPLIANCE WITH THE NMUD |
| | REGULATIONS. *** THIS IS REQUIRED PRIOR TO SCHEDULING A |
| | PLANNING BOARD HEARING SO THAT STAFF CAN VERIFY THAT |
| | THERE IS NO INCONSISTENCY WITH THE CODE REQUIREMENTS. |
| | THE MIXED-USE DEVELOPMENT REGULATIONS REQUIRE THAT |
| | STREETLIGHTS BE PROVIDED ALONG PUBLIC RIGHTS-OF-WAY |
| | ADJACENT TO THE SITE. CLEARLY SHOW THE PEDESTRIAN |
| | ORIENTED LIGHTING FOR THE SIDEWALKS ALONG THE SITE ON |
| | THE PLANS. THE LANDSCAPE AND CIVIL PLANS INDICATE THAT |
| | SOME EXISTING LIGHTS WILL REMAIN, BUT NOT ALL OF THE |
| | SITE IS COVERED. ADDITIONALLY, IT DOES NOT APPEAR THAT |
| | ALL OF THE EXISTING STREETLIGHT ORIENTATIONS ARE |
| | ACCURATELY DEPICTED. STAFF MUST BE ABLE TO VERIFY THAT |
| | THE LIGHTS DO NOT INTERFERE WITH PROPOSED TREE |
| | CANOPIES. |
| | |
| | 30) PROVIDE VERIFICATION THAT WHERE THE SIDEWALKS OR |
| | WALKWAYS CROSS THE DRIVEWAY ENTRANCES TO THE PARKING |
| | FACILITIES, LOADING AREAS, OR STREETS (BOTH PRIVATE AND |
| | PUBLIC), THE SIDEWALK OR WALKWAY IS CONTINUOUS AND |
| | REMAINS AT A CONSTANT LEVEL. |
| | |
| | 31) VERIZON HAS APPROVAL TO INSTALL A WIRELESS |
| | COMMUNICATION FACILITY POLE WITHIN THE BROADWAY |
| | RIGHT-OF-WAY ADJACENT TO THE SITE. SHOW THE POLE ON THE |
| | PLANS SO THAT STAFF CAN VERIFY THAT YOUR PLANS ARE |
| | DESIGNED TO NOT HAVE CONFLICTS (EX. PROPOSED PARKING |
| | SPACES, TREES, ETC.). |
| | |
| | 32) THE ARCHITECTURAL PLANS MUST SHOW THE MEDIANS IN |
| | BROADWAY THAT ARE SHOWN ON THE CIVIL AND LANDSCAPE |
| | PLANS. THE LANE WIDTH DIMENSIONS NEED TO BE PROVIDED AT |
| | THESE LOCATIONS. |
| | |
| | 33) PLEASE EXPLAIN WHY THE PROPOSED ROADWAY CROSS |
| | SECTIONS DO NOT COMPLY WITH THE FIGURES VII-16 AND |
| | VII-18 STREET SECTIONS. THE STREET SECTIONS, COMBINED |
| | WITH THE BUILDING SETBACKS ARE DESIGNED TO PROVIDE FOR |
| | WIDE, PEDESTRIAN FRIENDLY SIDEWALKS. THIS DOES NOT |
| | OCCUR ALONG PINEWOOD AND 25TH STREET. NO CROSS SECTION |
| | WAS PROVIDED FOR NORTHWOOD ROAD, 23RD STREET, THE |
| | BROADWAY EXTENSION AND THE PORTION OF PINEWOOD THAT IS |
| | REMAINING. ADDITIONALLY, PINEWOOD EXCEEDS THE NMUD |
| | MAXIMUM LANE WIDTH OF 10 FEET, WHICH UNLESS THE WIDER |
| | WIDTH IS REQUIRED BY THE TRAFFIC ENGINEER, REQUIRES A |
| | WAIVER. |
| | |
| | 34) BENCHES NEED TO BE DESIGNED TO PREVENT SLEEPING. |
| | |
| | 35) THERE ARE MULTIPLE LOCATIONS WHERE SHEET 301 SHOWS |
| | THE LANDSCAPE PATTERN OVERLAID ON PAVEMENT. THE SITE |
| | PLAN NEEDS TO ACCURATELY DEPICT WHAT IS SHOWN ON THE |
| | LANDSCAPE PLAN. |
| | |
| | 36) THE DESIGN OF THE PASEO NEEDS TO BE REEXAMINED: |
| | |
| | A. THE 4.33-FOOT DIMENSION BETWEEN THE PLANTERS AND THE |
| | STOREFRONTS IS NOT ADEQUATE FOR PEDESTRIANS TO |
| | COMFORTABLY WINDOW SHOP. |
| | B. THE PROPOSED TEXT HAD CONTEMPLATED RESTAURANT |
| | OUTDOOR SEATING IN THE PASEO, YET BASED ON THE PLANTER |
| | LOCATIONS, THERE IS NO ROOM FOR ANY OUTDOOR SEATING. |
| | C. THE MICRO MOBILITY STATION IS LOCATED DIRECTLY IN |
| | FRONT OF A DOORWAY. WHILE STAFF AGREES THAT A MICRO |
| | MOBILITY STATION NEEDS TO BE LOCATED IN CLOSE PROXIMITY |
| | TO THE PASEO, THE SPECIFIC LOCATION IS NOT AN |
| | APPROPRIATE LOCATION. PROVIDE THE MICRO MOBILITY |
| | STATION DIMENSIONS ON THE PLANS. |
| | |
| | PARKING/LOADING |
| | |
| | 38) NMUD ONLY PERMITS SURFACE PARKING LOTS TO THE SIDE |
| | OR THE REAR OF A PROPERTY. THE PROPOSED PARKING LOT |
| | FRONTING ON 23RD STREET DOES NOT MEET THIS STANDARD. |
| | PLANNING STAFF DOES NOT SUPPORT A CODE AMENDMENT TO |
| | PERMIT PARKING LOTS WITHIN THE BUILDING?S FRONT SETBACK |
| | AREA. |
| | |
| | 39) THE SURFACE LOT, WHICH WHILE NOT PERMITTED BY THE |
| | REGULATIONS, ALSO FAILS TO PROVIDE THE REQUIRED DIRECT |
| | PEDESTRIAN ACCESS TO A PUBLIC WALKWAY, NOR DOES IT |
| | PROVIDE THE REQUIRED LANDSCAPE BUFFER. |
| | |
| | 40) THE ENTRANCE TO THE SURFACE AND GARAGE PARKING AREA |
| | FROM PINEWOOD EXCEEDS THE MAXIMUM PERMITTED 24 FEET IN |
| | WIDTH DUE TO THE RADIUS STARTING INSIDE THE PROPERTY |
| | LINE. THE RADIUS/FLAIR MAY NOT WIDEN UNTIL IT IS WITHIN |
| | THE RIGHT-OF-WAY. |
| | |
| | 41) PROVIDE THE DIMENSIONS FOR THE LOADING ZONES ON THE |
| | PLANS SO THAT STAFF CAN VERIFY CODE COMPLIANCE. 70K SF |
| | OF COMMERCIAL USE REQUIRES TWO 10 X 50 FOOT SPACES. THE |
| | SPACES PROVIDED ON THE PLANS DO NOT APPEAR TO BE 50 |
| | FEET IN LENGTH. |
| | |
| | 42) ALL LEVELS OF THE PARKING GARAGE MUST BE SCREENED |
| | BY A LINER BUILDING CONTAINING A MINIMUM DEPTH OF 20 |
| | FEET IF HABITABLE SPACE. THIS IS NOT MET ALONG THE FULL |
| | LENGTH OF 25TH STREET, NORTHWOOD ROAD AND 23RD STREET |
| | AND PARTIALLY ALONG BROADWAY. THE PROPOSED CODE CHANGE |
| | DID NOT ADDRESS THE FAILURE TO PROVIDE SCREENING. STAFF |
| | WILL NOT SUPPORT BROADWAY NOT HAVING THE 20-FOOT DEPTH |
| | OF HABITABLE SPACE. IF THE CODE IS AMENDED ON THE OTHER |
| | FRONTAGES, THEN THERE NEEDS TO BE SPECIFIC LANGUAGE |
| | DEALING WITH ARCHITECTURAL TREATMENT AND THE PROVISION |
| | OF PLANAR BREAKS TO VARY THE FA?ADE IN ORDER TO CONCEAL |
| | THE NON-HABITABLE PARKING. |
| | |
| | 43) REPEAT COMMENT: DEAD END PARKING ROWS FOR |
| | UNASSIGNED PARKING ARE NOT PERMITTED WITHOUT A |
| | TURNAROUND SPACE. THE PUBLIC PARKING SPACES ON THE |
| | LOWER PARKING LEVEL MAY NOT BE LOCATED ON A DEAD-END |
| | AISLE WITHOUT A TURNAROUND SPACE. FIVE PARKING SPACES |
| | ON THE NORTHERN PORTION OF THE GARAGE WILL NEED TO BE |
| | CONVERTED INTO TURN AROUND SPACES. |
| | |
| | 44) UPDATED COMMENT: ALL PARKING GARAGES MUST HAVE |
| | DIRECT PEDESTRIAN ACCESS TO A PUBLIC WALKWAY. PROVIDE |
| | WHICH ELEVATORS ARE FOR USE BY THE PUBLIC TO ACCESS THE |
| | GROUND FLOOR. ADDITIONALLY, SINCE ALL OF THE ELEVATOR |
| | ACCESS IS THROUGH SOME SORT OF LOBBY ON THE GROUND |
| | FLOOR, PROVIDE INFORMATION ON HOW THE PUBLIC WILL BE |
| | ABLE TO ACCESS THE LOBBY. THE SOUTH LOBBY, WHICH |
| | PROVIDES ACCESS TO THE SOUTHERN, LOWER PARKING LEVEL |
| | SEEMS TO BE A RESIDENT LOBBY. |
| | |
| | 45) COLUMNS ARE SHOWN IN DRIVE AISLES ON NORTH PORTION |
| | OF THE LOWER LEVEL GARAGE. |
| | |
| | 46) MOST OF THE ADA ACCESS AISLES ON THE BOTH PARKING |
| | LEVELS APPEAR TO HAVE A PORTION OF THE COLUMN |
| | ENCROACHING. IF THIS IS NOT THE CASE, YOU NEED TO CLEAN |
| | UP THE DRAWINGS TO SHOW NO ENCROACHMENTS. |
| | |
| | 47) ADA SPACE NEXT TO STAIRS ON THE EASTERN WALL OF |
| | UPPER PARKING LEVEL HAS A COLUMN BLOCKING THE 5-FOOT |
| | WIDE ACCESS AISLE AND NEEDS TO HAVE AN EXTRA FOOT ALONG |
| | THE STAIRWELL WALL TO PERMIT ADEQUATE DOOR OPENING. |
| | |
| | 48) ALL PARKING SPACES NEXT TO A WALL NEED TO PROVIDE |
| | AN EXTRA FOOT TO PERMIT ADEQUATE DOOR OPENING. |
| | |
| | 49) THE PARKING SPACES THAT HEAD AGAINST WALLS NEED |
| | MORE CLARITY THAT THEY MEET THE REQUIRED 18-FOOT DEPTH. |
| | THE SPACES WITH DIMENSION TAGS SHOW THE END OF THE |
| | SPACE IN THE MIDDLE OF THE LINE SHOWING THE WALL, WHICH |
| | MAKES THEM TOO SHORT. IF THIS IS A LINE WEIGHT ISSUE ON |
| | THE PLAN VERSION, PROVIDE A CROSS SECTION THAT CLEARLY |
| | DEMONSTRATES THAT THE PARKING STALLS AND DRIVE AISLES |
| | HAVE SUFFICIENT DEPTH. THERE ARE SOME SPACES THAT THE |
| | PARKING SPACE BOX IS SHOWN IN THE WALL (EX OVERLOOKING |
| | THE RAMP ON THE LOWER PARKING LEVEL. |
| | |
| | 50) 20 SPACES ALONG THE NORTH WALL AND 10 SPACES ALONG |
| | THE SOUTH WALL OF THE UPPER PARKING LEVEL AND 15 SPACES |
| | ALONG THE NORTH WALL AND 8 SPACES ALONG THE SOUTH WALL |
| | ON THE LOWER PARKING LEVEL DO NOT MEET THE MINIMUM |
| | 18-FOOT STALL DEPTH. THIS IS 53 NON-COMPLIANT PARKING |
| | SPACES. |
| | |
| | 51) THE PARKING RAMPS MAY NOT BE SHOWN ENCROACHING THE |
| | COLUMNS AND WALLS ALONG THE WEST SIDE OF THE BUILDING. |
| | |
| | 52) THE STAIRWELLS ON THE EAST SIDE OF THE BUILDING |
| | ENCROACH INTO THE DRIVE AISLES RESULTING IN THE CODE |
| | REQUIRED 24-FOOT WIDTH NOT IN COMPLIANCE. |
| | |
| | 53) PROVIDE THE DETAILS ON HOW PEOPLE ARE PROTECTED |
| | FROM THE EDGES OF THE PARKING RAMPS. THIS MAY AFFECT |
| | THE PARKING STALLS ADJACENT TO THE RAMPS. |
| | |
| | 54) THE PARKING STALL DETAIL PROVIDED ON THE CIVIL PLAN |
| | DOES NOT MEET CITY STANDARDS. PROVIDE THE ACCURATE |
| | DETAIL. |
| | |
| | 55) THE RESPONSE STATES THAT THE TANDEM SPACES ARE FOR |
| | RESIDENTS, WHICH DOES NOT PERMIT THE INSIDE SPACE TO BE |
| | COUNTED TOWARD MEETING THE MINIMUM PARKING REQUIREMENTS |
| | SINCE THE NMUD REQUIRES ONE PARKING SPACE PER UNIT. THE |
| | INSIDE SPACE CANNOT BE ASSIGNED TO A UNIT THAT IS |
| | DIFFERENT FROM THE OUTSIDE SPACE, SO IT MAY NOT COUNT. |
| | |
| | 56) THE PARKING PROVIDED TABLES SHALL CLEARLY SEPARATE |
| | THE PROVIDE ADA SPACES FROM THE TOTAL PROVIDED SPACES |
| | FOR EACH CATEGORY. THE CURRENT LINE ITEMS MAKE IT LOOK |
| | LIKE THERE ARE ADA SPACES IN ADDITION TO THE REGULAR |
| | SPACES. |
| | |
| | 57) 77,820 SQUARE FEET OF COMMERCIAL REQUIRES 156 |
| | PARKING SPACES, NOT 152 OR 153 AS SHOWN ON DIFFERING |
| | PARKING TABLES. THE TOTAL REQUIRED PARKING IS 534 |
| | SPACES. |
| | |
| | 58) 53 PUBLIC PARKING SPACES ARE REQUIRED IN ACCORDANCE |
| | WITH THE AGREEMENT WITH CRA AND NEED TO BE REFLECTED ON |
| | THE PARKING TABLE AND THE PLANS. |
| | |
| | 59) EVEN WHEN NOT REMOVING THE PARKING SPACES THAT DO |
| | NOT COMPLY WITH CODE DEPTH, WALL ADJACENCY OR DEAD-END |
| | ROWS, THE PROJECT DOES NOT PROVIDE CODE MINIMUM |
| | PARKING. THERE ARE 592 SPACES LISTED AS PROVIDED. |
| | REMOVING THE 18 TANDEM AND 53 REQUIRED PUBLIC CRA |
| | SPACES, RESULTS IN ONLY 521 PARKING SPACES PROVIDED, |
| | WHICH IS LESS THAN THE REQUIRED 534 SPACES. |
| | |
| | 60) THE CRA AGREEMENT REQUIRES THAT THE DEVELOPER |
| | CONSTRUCT PUBLIC PARKING SPACES IN AN AMOUNT TO EQUAL |
| | 10% OF THE PARKING REQUIRED FOR THE PROJECT (53 PARKING |
| | SPACES). WHILE THE PLANS DO NOT CLEARLY DEMONSTRATE |
| | WHERE THE 53 CRA REQUIRED PARKING SPACES ARE LOCATED, |
| | IT APPEARS THAT SOME OF THEM ARE INTENDED TO BE LOCATED |
| | WITHIN THE ON-STREET PARKING SHOWN ON THE PLANS. SINCE |
| | THE LANGUAGE REQUIRES THAT NEW PARKING SPACES BE |
| | CONSTRUCTED TO MEET THE CRA REQUIREMENT, PROVIDE AN |
| | EXISTING PARKING INVENTORY OF THE ON-STREET PARKING |
| | SPACES. EXISTING PARKING SPACES MAY NOT BE COUNTED AS |
| | NEWLY CONSTRUCTED SPACES, AND ANY SPACES BEING REMOVED, |
| | WILL NEED TO BE REPLACED AND MAY NOT BE COUNTED AS |
| | NEWLY CREATED PARKING SPACES. |
| | |
| | 61) THE PROJECT REQUIRES 16 BICYCLE SPACES FOR THE |
| | COMMERCIAL PORTION AND 38 BICYCLE SPACES FOR THE |
| | RESIDENTIAL PORTION. THERE ARE 54 TOTAL REQUIRED |
| | BICYCLE PARKING SPACES. THIS SHALL BE CORRECTLY |
| | REFLECTED ON THE PARKING TABLE. |
| | |
| | 62) WHO HAS ACCESS TO THE BICYCLE STORAGE AREA ON THE |
| | UPPER PARKING LEVEL OF BUILDING A? |
| | |
| | 63) PROVIDE THE DIMENSIONS AND DETAIL FOR THE RACKS, |
| | INCLUDING THE NUMBER OF SPACES, LOCATED IN THE BICYCLE |
| | STORAGE ROOM AS WELL AS THE DIMENSIONS OF THE ROOM AND |
| | THE RACKS IN THE ROOM. THIS SHALL BE PROVIDED ON ITS |
| | OWN BICYCLE ROOM DETAIL SHEET THAT THIS AT A LEGIBLE |
| | SCALE. |
| | |
| | 64) WHERE IS THE REQUIRED SHOWER AND CHANGING FACILITY |
| | FOR THE COMMERCIAL TENANTS OF BUILDING A? |
| | |
| | 65) ALL ON-STREET BICYCLE PAD DIMENSIONS MUST BE |
| | CLEARLY SHOWN ON THE PLANS SO THAT STAFF CAN VERIFY |
| | THAT THERE IS SUFFICIENT ROOM AND THAT SIDEWALKS ARE |
| | NOT BLOCKED. NUMEROUS BICYCLES RACKS ARE CURRENTLY |
| | SHOWN BLOCKING SIDEWALKS. THE BICYCLE RACK DETAILS FOR |
| | THESE SPACES NEED TO BE PROVIDED. |
| | |
| | 66) THE MICRO MOBILITY STATION NORTH OF BUILDING B MUST |
| | BE RELOCATED. IT INTERFERES WITH A PROPOSED BICYCLE |
| | RACK. |
| | |
| | LANDSCAPE |
| | |
| | 67) UPDATED COMMENT: THANK YOU FOR PROVIDING THE |
| | REQUIRED LANDSCAPE BUFFER STRIP ALONG THE RAILROAD |
| | RIGHT-OF-WAY. THE SITE PLAN SEEMS TO SHOW COLUMNS |
| | ENCROACHING INTO THE LANDSCAPE BUFFER, WHICH IS NOT |
| | PERMITTED. PLEASE REVIEW THE DRAWINGS FOR CLARITY SINCE |
| | THE CIVIL AND LANDSCAPE PLANS DO NOT SHOW AN |
| | ENCROACHMENT. |
| | |
| | 68) PROVIDE THE DIMENSIONS ON THE PLANS TO VERIFY THAT |
| | A LANDSCAPE STRIP, A MINIMUM OF FIVE FEET IN WIDTH, IS |
| | PROVIDED ALONG THE CURBSIDE ALONG THE STREET EDGE. IF |
| | TREE GRATES ARE USED INSTEAD OF A LANDSCAPE STRIP, THEN |
| | THE REQUIRED DIMENSION SHALL BE PROVIDED ON THE SITE |
| | PLAN. NOTE: THE SOUTHWEST PORTION OF THE SITE FAILS TO |
| | MEET THIS REQUIREMENT. THE LANDSCAPE AREA ADJACENT TO |
| | THE PASEO ON BROADWAY ALSO FAILS TO MEET THIS |
| | REQUIREMENT. |
| | |
| | 69) THE CODE STATES THAT A LANDSCAPE STRIP, NOT TREE |
| | GRATES IS THE PREFERRED OPTION WHEN NO ON-STREET |
| | PARKING IS PROVIDED. 23RD STREET AND 25TH STREET HAVE |
| | NOT ON-STREET PARKING, SO A LANDSCAPE STRIP IS |
| | REQUIRED. |
| | |
| | 70) THE CODE REQUIRES A MINIMUM UNOBSTRUCTED 60-INCH |
| | AREA FOR THE SIDEWALK. THE SITE PLAN FAILS TO SHOW THE |
| | EXISTING UTILITY POLES THAT ARE TO REMAIN ALONG 23RD |
| | STREET ADJACENT TO BUILDING B. THEY ARE SHOWN ON THE |
| | LANDSCAPE PLAN ? ENCROACHING INTO THE REQUIRED SIDEWALK |
| | WIDTH, OVERLAPPING THE TREE PITS AND IN CONFLICT WITH |
| | PROPOSED STREET TREE CANOPIES. |
| | |
| | 71) THERE IS A TREE SHOWN WHERE THE EXISTING FIRE |
| | HYDRANT TO REMAIN IS SHOWN ON THE CIVIL PLAN IN FRONT |
| | OF BUILDING C. |
| | |
| | 72) THERE ARE OAK TREES BEING SHOWN PLANTED ON TOP OF A |
| | GAS LINE ALONG NORTHWOOD ROAD. PLEASE PROVIDE THE DEPTH |
| | OF THE GAS LINE SO THAT STAFF CAN VERIFY THAT THERE IS |
| | NO CONFLICT. |
| | |
| | HISTORIC PRESERVATION FUND |
| | |
| | 73) THIS PROJECT IS UTILIZING THE CORE SUBDISTRICT |
| | HISTORIC PRESERVATION HEIGHT BONUS. PLEASE PROVIDE THE |
| | AMOUNT OF SQUARE FOOTAGE BEING PROVIDED ABOVE THE |
| | 80-FOOT BASE ZONING HEIGHT. |
| | |
| | PRIVATE OPEN SPACE |
| | |
| | 74) PRIVATE OPEN SPACE REQUIREMENTS ? NO CALCULATIONS |
| | WERE PROVIDED. PRIVATE OPEN SPACES SHALL PROVIDE SHADED |
| | AREAS, AND THEIR GROUND SURFACE SHALL BE A COMBINATION |
| | OF PAVING MATERIALS, LAWN, OR GROUND COVER. |
| | |
| | 75) BUILDING A IS A MIXED-USE TOWER BUILDING, SO IT IS |
| | REQUIRED TO PROVIDE A MINIMUM OF 10% COMMON, PRIVATE |
| | OPEN SPACE ON SITE. IT APPEARS THAT THE INTENT IS TO |
| | PROVIDE THE COMMON, PRIVATE OPEN SPACE ON THE ROOF OF |
| | THE PARKING DECK. PROVIDE VERIFICATION THAT THE MINIMUM |
| | AREA IS PROVIDED. |
| | |
| | 76) BUILDING B IS A MIXED-USE FLEX BUILDING, SO IT IS |
| | REQUIRED TO PROVIDE A MINIMUM OF 10% COMMON, PRIVATE |
| | OPEN SPACE ON SITE. THE PLANS SHOW NO COMMON, PRIVATE |
| | OPEN SPACE PROVIDED FOR THIS BUILDING. |
| | |
| | 77) BUILDING C IS A MIXED-USE FLEX BUILDING, SO IT IS |
| | REQUIRED TO PROVIDE A MINIMUM OF 10% COMMON, PRIVATE |
| | OPEN SPACE ON SITE. THE PLANS SHOW NO COMMON, PRIVATE |
| | OPEN SPACE PROVIDED FOR THIS BUILDING. |
| | |
| | |
| |