| 2021-11-17 20:39:37 | CASE NO. 1895 |
| | NORTHWOOD COMMONS - NMUD ANCHOR SITE |
| | BROADWAY & 24TH STREET |
| | |
| | - CONTACT ERIC SCHNEIDER @ (561) 822-1446, |
| | [email protected] |
| | |
| | - PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN |
| | WRITTEN FORMAT. |
| | |
| | - WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF FOUR |
| | (4) PAPER COPIES AND AN ELECTRONIC COPY IN .PNG FORMAT |
| | OF ALL PLANS. PLEASE NOTE THAT CHANGES ON THE |
| | RESUBMITTED PLANS OR THE SUBMITTAL OF INFORMATION/PLANS |
| | TO ADDRESS THE COMMENTS MAY RESULT IN ADDITIONAL |
| | COMMENTS. |
| | |
| | - THE PPRC COMMENTS SHALL BE SUFFICIENTLY ADDRESSED AND |
| | SUBMITTED TO THE PLANNING DIVISION BY 5 PM ON FRIDAY, |
| | DECEMBER 3, 2021, TO BE ELIGIBLE TO BE SCHEDULED FOR |
| | THE JANUARY 18, 2022 PLANNING BOARD MEETING. |
| | |
| | - PLEASE NOTE THAT IF THE PLANNING DIVISION HAS NOT |
| | RECEIVED A RESPONSE TO THE PPRC COMMENTS WITHIN 60 DAYS |
| | FROM THE DATE OF THE PPRC MEETING (BY JANUARY 18, |
| | 2022), THE PLANNING DIVISION MAY NOTIFY THE APPLICANT |
| | THAT THE CASE IS CONSIDERED WITHDRAWN. ANY FURTHER |
| | ACTION SHALL REQUIRE A NEW DEVELOPMENT APPLICATION. |
| | |
| | - PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1) |
| | RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY ISSUED |
| | COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE |
| | APPLICANT WILL BE ASSESSED A RESUBMITTAL FEE. SUCH FEE |
| | WILL BE 20% OF THE ORIGINAL APPLICATION FEE ($600). |
| | |
| | - PUBLIC HEARING NOTIFICATION SIGNAGE SHALL BE POSTED |
| | IN ACCORDANCE WITH THE REQUIREMENTS OF SECTION |
| | 94-39(I)(5) OF THE ZONING AND LAND DEVELOPMENT |
| | REGULATIONS. |
| | |
| | PLANNING STAFF BEGAN A REVIEW OF THE PLANS AND BEGAN TO |
| | LIST DISCREPANCIES WITH THE ZONING AND LAND DEVELOPMENT |
| | REGULATIONS AND GENERAL ISSUES WITH THE QUALITY OF THE |
| | INFORMATION PRESENTED ON THE PLANS. AFTER IDENTIFYING |
| | OVER 30 COMMENTS, MANY WHICH WILL REQUIRE A REDESIGN OF |
| | THE PLANS, PLANNING STOPPED THE REVIEW. THE PLANS NEED |
| | TO BE CORRECTED TO COMPLY WITH THE CODE AND THE |
| | INTERNAL INCONSISTENCIES AMONG THE PLAN SHEETS. STAFF |
| | DID NOT FULLY VET OPEN SPACE, SETBACKS, STREETSCAPE, |
| | MECHANICAL SCREENING AND LANDSCAPE COMPLIANCE TO NAME A |
| | FEW, SO JUST BECAUSE COMMENTS WERE NOT ISSUED ABOUT A |
| | PARTICULAR ASPECT OF THE PLAN, DO NOT ASSUME IT |
| | COMPLIES. BASED ON WHAT STAFF HAS LISTED BELOW, STAFF |
| | IS CONFIDENT THAT THERE ARE ADDITIONAL CODE |
| | REQUIREMENTS THAT ARE NOT MET. |
| | |
| | 1) THE BUILDING HEIGHT IS NOT BEING MEASURED CORRECTLY. |
| | IT DOES NOT START AT THE FINISHED FLOOR ELEVATION. |
| | |
| | 2) BUILDING A DOES NOT COMPLY WITH THE MAXIMUM NUMBER |
| | OF STORIES AND BUILDING HEIGHT PERMITTED. |
| | |
| | A. THE MAXIMUM NUMBER OF STORIES PERMITTED WITHIN CORE |
| | PARCELS A & B IS 8 STORIES (WITH THE HEIGHT BONUS). THE |
| | BUILDING HAS 9 STORIES. IN ACCORDANCE WITH SECTION |
| | 94-209.B.5., EACH PARKING GARAGE LEVEL AT THE FRONTAGE |
| | LINE(S) SHALL EQUAL ONE STORY FOR THE PURPOSES OF |
| | MEASURING BUILDING HEIGHT. THE PARKING GARAGE LEVEL |
| | THAT YOU ARE DESIGNATING AS A MEZZANINE IS NOT A |
| | MEZZANINE, IT IS A STORY SINCE IT IS ALONG MULTIPLE |
| | FRONTAGE LINES. |
| | B. THE MAXIMUM NUMBER OF STORIES/BUILDING HEIGHT |
| | PERMITTED WITHIN THE AREA SOUTH OF CORE PARCEL B IS 4 |
| | STORIES/56 FEET. THE ENTIRE ROW OF UNITS ON THE SOUTH |
| | END OF THE BUILDING STARTING AT RESIDENCE LEVEL 4 |
| | EXCEED THE PERMITTED NUMBER OF STORIES AND HEIGHT |
| | PERMITTED. |
| | |
| | 3) BUILDING B DOES NOT COMPLY WITH THE NUMBER OF |
| | STORIES AND BUILDING HEIGHT PERMITTED. |
| | |
| | A. THE MAXIMUM NUMBER OF STORIES/BUILDING HEIGHT |
| | PERMITTED WITHIN THE HISTORICALLY DESIGNATED PORTION OF |
| | THE TRANSITION SUBDISTRICT IS 3 STORIES/44 FEET. THE |
| | BUILDING IN THIS AREA EXCEEDS THE PERMITTED NUMBER OF |
| | STORIES AND HEIGHT. IF THE GROUND LEVEL IS INTENDED TO |
| | CONTAIN A MEZZANINE THAT WOULD NOT COUNT AS A STORY, |
| | THEN COMPLETE FLOOR PLANS SHOWING HOW THIS IS IN |
| | REALITY A MEZZANINE MUST BE PROVIDED. THE CURRENT PLANS |
| | SHOW THIS AS A FULL FLOOR. |
| | B. THE MAXIMUM NUMBER OF STORIES PERMITTED WITHIN THE |
| | AREA SOUTH OF CORE PARCEL B IS 4 STORIES FEET. THE |
| | BUILDING IN THIS AREA EXCEEDS THE PERMITTED NUMBER OF |
| | STORIES. IF THE GROUND LEVEL IS INTENDED TO CONTAIN A |
| | MEZZANINE THAT WOULD NOT COUNT AS A STORY, THEN |
| | COMPLETE FLOOR PLANS SHOWING HOW THIS IS IN REALITY A |
| | MEZZANINE MUST BE PROVIDED. THE CURRENT PLANS SHOW THIS |
| | AS A FULL FLOOR. |
| | |
| | 4) BUILDING C DOES NOT COMPLY WITH THE NUMBER OF |
| | STORIES AND BUILDING HEIGHT PERMITTED. |
| | |
| | A. THE MAXIMUM NUMBER OF STORIES/BUILDING HEIGHT |
| | PERMITTED WITHIN THE HISTORICALLY DESIGNATED PORTION OF |
| | THE TRANSITION SUBDISTRICT IS 3 STORIES/44 FEET. THE |
| | BUILDING IN THIS AREA EXCEEDS THE PERMITTED NUMBER OF |
| | STORIES AND HEIGHT. THE PLANS CLEARLY CALL OUT A |
| | 2-STORY GROUND LEVEL. |
| | B. THE MAXIMUM NUMBER OF STORIES PERMITTED WITHIN THE |
| | AREA SOUTH OF CORE PARCEL B IS 4 STORIES FEET. THE |
| | BUILDING IN THIS AREA EXCEEDS THE PERMITTED NUMBER OF |
| | STORIES. THE PLANS CLEARLY CALL OUT A 2-STORY GROUND |
| | LEVEL. |
| | |
| | 5) THERE ARE PLAN SHEETS THAT CONTINUE TO SHOW BUILDING |
| | C ENCROACHING INTO THE BROADWAY RIGHT-OF-WAY, WHICH IS |
| | NOT PERMITTED. |
| | |
| | 6) THE GROUND FLOOR UNIT THAT WAS "CUT" TO AVOID |
| | ENCROACHING INTO THE BROADWAY RIGHT-OF-WAY WAS NOT |
| | UPDATED TO SHOW THE SQUARE FOOTAGE OR THAT IT EVEN |
| | FUNCTIONS. |
| | |
| | 7) THE BUILDING A UNIT PLANS ARE INCOMPLETE. THERE ARE |
| | UNITS THAT HAVE NOT INFORMATION PROVIDED. |
| | |
| | 8) THE ELEVATIONS FOR BUILDINGS B AND C DO NOT MATCH |
| | THE FLOOR PLANS. |
| | |
| | 9) FULL FLOOR PLANS FOR BUILDINGS B AND C ARE REQUIRED |
| | FOR STAFF TO SEE HOW THE BUILDINGS FUNCTION AS SHOWN. |
| | |
| | 10) PROVIDE A TRAFFIC PERFORMANCE STANDARDS APPROVAL |
| | LETTER FROM THE PALM BEACH COUNTY TRAFFIC DIVISION FOR |
| | THE FULL SCOPE OF THE PROPOSED DEVELOPMENT. |
| | |
| | 11) THE NUMBER OF UNITS AND THE NON-RESIDENTIAL SQUARE |
| | FOOTAGE LISTED IN THE TRAFFIC IMPACT ANALYSIS DO NOT |
| | MATCH THE SITE DATA ON THE PLANS. THE TRAFFIC IMPACT |
| | ANALYSIS MUST REFLECT THE FULL SCOPE OF THE |
| | DEVELOPMENT. |
| | |
| | 12) PROVIDE A PREDETERMINATION LETTER FROM FDOT FOR THE |
| | IMPROVEMENTS WITHIN THE FDOT RIGHTS-OF-WAY OF BROADWAY |
| | AND 25TH STREET ADJACENT TO THE PROJECT. |
| | |
| | 13) PROVIDE THE LETTER FROM COMCAST CONFIRMING THAT THE |
| | PROPOSED PROJECT DOES NOT ENCROACH INTO THEIR EASEMENTS |
| | OR OTHERWISE INTERFERE WITH THE PROVISIONS OF THEIR |
| | SERVICES. |
| | |
| | 14) SECTION 94-209.J.1.C REQUIRES THAT PROJECTS WITH |
| | THREE OR MORE DISTINCTLY SEPARATE BUILDINGS HAVE |
| | SUBSTANTIALLY DIFFERENT FRONT ELEVATIONS. SUBSTANTIALLY |
| | DIFFERENT FRONT ELEVATIONS SHALL INCLUDE BUT NOT BE |
| | LIMITED TO VARIATIONS IN FENESTRATION, MATERIAL, |
| | MASSING AND COLOR. THE PLANS AND NARRATIVE MUST VERIFY |
| | THAT THE BUILDINGS COMPLY WITH THIS REQUIREMENT. |
| | |
| | 15) SHEET A404 SHOWS BUILDING C AS HAVING 4 EAST |
| | ELEVATIONS. WHAT SHOULD BE LABELED AS THE NORTH AND |
| | SOUTH ELEVATIONS DO NOT ALIGN WITH THE KEY PLAN. |
| | |
| | 16) SHEET A405 SHOWS BUILDING B AS HAVING 4 SOUTH |
| | ELEVATIONS. |
| | |
| | 17) THE CITY'S MIXED USE DISTRICT DEFINES OPEN SPACE AS |
| | AN IMPROVED OUTDOOR AREA OPEN TO THE SKY. FIGURE VII-3 |
| | DESIGNATED PUBLIC OPEN SPACES AND GREENWAY REGULATING |
| | PLAN REQUIRES PUBLIC OPEN SPACE WHERE 24TH STREET IS |
| | PROPOSED FOR ABANDONMENT. THE DESIGN OF THE PROJECT |
| | DOES NOT HAVE THIS AREA COMPLY WITH THE OPEN SPACE |
| | DEFINITION; THEREFORE, THIS AREA DOES NOT COMPLY WITH |
| | THE CODE REQUIREMENT. |
| | |
| | 18) THE ENTRANCES TO THE SURFACE AND GARAGE PARKING |
| | AREAS EXCEED THE MAXIMUM PERMITTED 24 FEET IN WIDTH. |
| | |
| | 19) ALL LEVELS OF THE PARKING GARAGE MUST BE SCREENED |
| | BY A LINER BUILDING CONTAINING A MINIMUM DEPTH OF |
| | HABITABLE SPACE. STAFF RECOGNIZES THAT A VARIANCE TO |
| | THIS PROVISION HAS BEEN PROVIDED, BUT STAFF DOES NOT |
| | SUPPORT THE WAIVER REQUEST. |
| | |
| | 20) PROVIDE VERIFICATION THAT THE PARKING GARAGE HAS |
| | DIRECT PEDESTRIAN ACCESS TO A PUBLIC WALKWAY. |
| | |
| | 21) SECTION 94-209.F.1.E REQUIRES A LANDSCAPE BUFFER |
| | STRIP OF AT LEAST FIVE FEET WIDE SHALL BE PROVIDED |
| | ALONG THE ENTIRE EDGE OF A PROPERTY ABUTTING A RAILROAD |
| | RIGHT-OF-WAY. THE REQUIRED BUFFER HAS NOT BEEN |
| | PROVIDED. PLANNING STAFF WILL NOT SUPPORT A WAIVER OF |
| | THIS REQUIREMENT. |
| | |
| | 22) NO DETAILS WERE PROVIDED ON THE SITE LIGHTING TO |
| | VERIFY COMPLIANCE WITH THE NMUD REGULATIONS. |
| | |
| | 23) PROVIDE HOW THE STOREFRONTS AT THE ABANDONED |
| | PORTION OF 24TH STREET ARE BE DIRECTLY ACCESSIBLE FROM |
| | A STREET FRONTAGE, URBAN GREENWAY OR PUBLIC, |
| | SEMI-PUBLIC OR PRIVATE OPEN SPACE, GIVEN THAT THE |
| | ABANDONED PORTION OF 24TH STREET DOES NOT MEET ANY OF |
| | THESE DEFINITIONS. |
| | |
| | 24) NO INFORMATION WAS PROVIDED TO VERIFY THE ACTIVE |
| | USE STANDARDS, THE FACADE ARTICULATION REQUIREMENTS, |
| | THE ARCHITECTURAL TREATMENT STANDARDS OR THE |
| | FENESTRATION STANDARDS. |
| | |
| | 25) NMUD DOES NOT PERMIT DWELLING UNITS CONTAINING LESS |
| | THAN 550 SQUARE FEET, YET THE UNIT MATRIX SHOWS AT |
| | LEAST 36 UNITS FAILING TO MEET THIS STANDARD. |
| | |
| | 26) DEAD END PARKING ROWS ARE NOT PERMITTED WITHOUT A |
| | TURNAROUND SPACE. THERE ARE NUMEROUS THROUGHOUT THE |
| | GARAGE. |
| | |
| | 27) THE PARKING SPACES AT THE TOP OF THE RAMPS ARE |
| | UNSAFE GIVEN THE SLOPE OF THE RAMPS. |
| | |
| | 28) DESCRIBE WHO WILL USE THE TANDEM SPACES. |
| | |
| | 29) THERE ARE MISLABELED DIMENSION TAGS IN THE GARAGE. |
| | |
| | 30) THERE ARE STAIRS THAT DIRECTLY ENCROACH PARKING |
| | SPACES AND DOORWAYS THAT CANNOT BE ACCESSED IF A CAR IS |
| | PARKED IN THE SPACE IN FRONT OF THE DOOR. |
| | |
| | 31) NO DETAILS ON THE BICYCLE PARKING WAS PROVIDED, |
| | BOTH FOR THE BICYCLE STORAGE ROOM AND THE STREET |
| | BICYCLE PARKING. |
| | |
| | 32) THE VEHICLE LOADING/SERVICE AREAS MAY NOT USE CITY |
| | RIGHTS-OF-WAY FOR MANEUVERING. |
| | |
| | 33) THE ARCHITECTURAL PLANS SHOW SUPPORT COLUMNS |
| | LOCATED WITHIN PINEWOOD AVENUE, WHICH IS NOT PERMITTED. |
| | PROVIDE PLANS THAT SHOW THE LOCATIONS OF THE STRUCTURAL |
| | COLUMNS THAT ARE REQUIRED TO SUPPORT THE SPANS ACROSS |
| | PINEWOOD AVENUE AND THE ABANDONED PORTION OF 25TH |
| | STREET SO THAT STAFF CAN EVALUATE THE IMPACTS ON THE AT |
| | GRADE LAYOUT. |
| | |
| | 34) THE INVITATION TO NEGOTIATE FOR THIS PROJECT |
| | INCLUDED THE FOLLOWING LANGUAGE, "TRIRAIL COASTAL LINK |
| | THE SOUTH FLORIDA REGIONAL TRANSIT AUTHORITY (SFRTA), |
| | ALONG WITH STATE, REGIONAL AND LOCAL PARTNERS, IS |
| | PLANNING THE CREATION OF A TRIRAIL COASTAL LINK RAIL |
| | CONNECTION ALONG THE FEC RAILWAY FROM MIAMI TO JUPITER. |
| | IN PREVIOUS PLANS THE ANCHOR SITE WAS CONSIDERED AS ONE |
| | OF THE POTENTIAL LOCATIONS FOR A FUTURE TRI-RAIL STOP. |
| | CURRENT PLANS DO NOT INCLUDE THE ANCHOR SITE IN "PHASE |
| | 1"? OF THE RAIL CONNECTION; HOWEVER, DEVELOPMENT ON |
| | THIS SITE SHOULD CONSIDER THE POSSIBILITY OF A FUTURE |
| | STOP AND DEVELOPERS WOULD BE ENCOURAGED TO SUPPORT THE |
| | RAIL CONNECTION AT THIS LOCATION. THE CRA'S NORTH END |
| | VISION CONSIDERS THE ANCHOR SITE AS A PRIME RAIL STOP |
| | LOCATION. CURRENT LOCATIONS AND STUDIES CAN BE LOCATED |
| | AT HTTP://TRI-RAILCOASTALLINK.COM/." EXPLAIN HOW THE |
| | PLANS PROVIDE A CONNECTION AT THIS LOCATION. |
| | |
| |