Plan Review Notes
Plan Review Notes For Project Z21080014
Project Number Z21080014
Review Stop TRAFFIC
Sequence Number 3
Notes
Date Text
2022-06-29 01:04:581) SATISFIED. PROVIDE COUNTY TPS LETTER
 2) SATISFIED. PROVIDE A LETTER BY A PROFESSIONAL
 ENGINEER VALIDATING THE BI-DIRECTIONAL DRIVEWAY
 3) SATISFIED. ON THE SITE PLAN, PLEASE SHOWCASE BASIC
 CURB DETAILS (I.E. DRIVEWAY, CURB CUT, AND PARKING
 STALLS) ON THE OPPOSITE SIDE OF THE ROADS SURROUNDING
 THE PROPOSED DEVELOPMENT. SHEET C-4, PER LATEST
 RESPONSE, DOES NOT ADDRESS THIS COMMENT
 4) SATISFIED. PROVIDE AUTOTURN ANALYSIS FOR GARBAGE
 TRUCK AND/OR SERVICE VEHICLES DRIVING IN AND OUT OF THE
 PROPOSED DEVELOPMENT WITH VEHICLE DYNAMIC ENVELOPES
 CLEARLY DEFINED. ANALYSIS SHOULD BE PROVIDED IN A
 SEPARATE FILE/DRAWING. PLEASE PROVIDE CLEAR EXPLANATION
 ON GARBAGE DISPOSAL OPERATIONS. ARE THE 96-GALLON
 CONTAINERS BEING PICKED UP INSIDE THE PROPOSED
 DEVELOPMENT OR MOVED AND RETRIEVED BY THE ROADSIDE
 CURB?
 5) SATISFIED. PROVIDE PARKING TABLE SHOWCASING THE
 NUMBER OF REQUIRED AND PROVIDED PARKING SPACES,
 INCLUSIVE OF ADA AND BICYCLE ONES.
 6) NOT SATISFIED. SHOWCASE THE DISTANCE BETWEEN THE
 EXISTING LIGHT POLE AND THE PROPOSED DRIVEWAY FLARE. A
 MINIMUM OF 3 FEET CLEAR ZONE HAS TO BE MAINTAINED.
 PLEASE DRAW A CIRCLE WITH A 3 FEET RADIUS AROUND THE
 POLE TO VALIDATE SUCH DISTANCE, PROVIDE DOCUMENT NAME
 AND SHEET NUMBER SHOWCASING SUCH FEATURE.
 7) NOT SATISFIED. HOW DOES A VEHICLE TURN AROUND WHEN
 ALL PARKING STALLS ARE OCCUPIED? PROVIDE AUTOTURN
 SHOWCASING THE MANEUVER, ASSUMING ALL STALLS ARE
 OCCUPIED. PER CITY CODE 93-485(M): ALL PARKING &
 LOADING MANEUVERS SHOULD BE CONTAINED ON-SITE. NO
 MANEUVERING OFF-STREET
  
 VALERIO ORICCHIO
 CITY TRANSPORTATION ENGINEER
 561-494-1092
 [email protected]
  