| Plan Review Notes For Project Z21070024 |
| Project Number |
Z21070024 |
|
| Review Stop |
STORM |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2021-08-12 09:15:55 | 1. BOUNDARY SURVEY INDICATES THE PROPERTY IS WITHIN A | | | SPECIAL FLOOD HAZARD AREA (SFHA) WITH A BASE FLOOD | | | ELEVATION (BFE) OF 12.0 FEET NAVD. STRUCTURES WITHIN A | | | SFHA ARE TO HAVE A MINIMUM OF TWO FEET OF FREEBOARD | | | ABOVE THE BFE. | | | | | | 2. CHECK THE SFWMD DRAINAGE BASIN LISTED IN THE JFK LOS | | | LETTER DOCUMENT. THE PROPERTY IS EAST OF THE C-17 | | | CANAL. | | | | | | 3. THE DESIGN OF STORMWATER MANAGEMENT SYSTEM FOR | | | FUTURE DEVELOPMENT OF THE SITE IS TO MEET SFWMD ERP | | | CRITERIA FOR WATER QUALITY TREATMENT AND PEAK FLOW | | | ATTENUATION. | | | | | | 4. CONGRESS AVENUE IS MAINTAINED BY PALM BEACH COUNTY. | | | | | | 5. THE CITY'S OFFICIAL VERTICAL DATUM PER CITY CODE IS | | | NGVD1929. THE CITY IS ALLOWING SURVEYS AND PLANS TO USE | | | NAVD1988 PROVIDED THE CONVERSION EQUATION BETWEEN | | | NAVD1988 AND NGVD1929 IS ALSO PROVIDED. THE CONVERSION | | | EQUATION IS TO BE PROVIDED ON ALL SURVEYS AND CIVIL | | | PLANS CONTAINING ELEVATION INFORMATION. | | | | | | TRACY WARD, PE | | | SENIOR STORMWATER ENGINEER | | | ENGINEERING SERVICES DEPARTMENT | | | 561-494-1120 (O) | | | 561-351-0510 (M) | | | [email protected] | | | |
| |
Print |
|