Date Text
2021-08-12 09:15:551. BOUNDARY SURVEY INDICATES THE PROPERTY IS WITHIN A
 SPECIAL FLOOD HAZARD AREA (SFHA) WITH A BASE FLOOD
 ELEVATION (BFE) OF 12.0 FEET NAVD. STRUCTURES WITHIN A
 SFHA ARE TO HAVE A MINIMUM OF TWO FEET OF FREEBOARD
 ABOVE THE BFE.
  
 2. CHECK THE SFWMD DRAINAGE BASIN LISTED IN THE JFK LOS
 LETTER DOCUMENT. THE PROPERTY IS EAST OF THE C-17
 CANAL.
  
 3. THE DESIGN OF STORMWATER MANAGEMENT SYSTEM FOR
 FUTURE DEVELOPMENT OF THE SITE IS TO MEET SFWMD ERP
 CRITERIA FOR WATER QUALITY TREATMENT AND PEAK FLOW
 ATTENUATION.
  
 4. CONGRESS AVENUE IS MAINTAINED BY PALM BEACH COUNTY.
  
 5. THE CITY'S OFFICIAL VERTICAL DATUM PER CITY CODE IS
 NGVD1929. THE CITY IS ALLOWING SURVEYS AND PLANS TO USE
 NAVD1988 PROVIDED THE CONVERSION EQUATION BETWEEN
 NAVD1988 AND NGVD1929 IS ALSO PROVIDED. THE CONVERSION
 EQUATION IS TO BE PROVIDED ON ALL SURVEYS AND CIVIL
 PLANS CONTAINING ELEVATION INFORMATION.
  
 TRACY WARD, PE
 SENIOR STORMWATER ENGINEER
 ENGINEERING SERVICES DEPARTMENT
 561-494-1120 (O)
 561-351-0510 (M)
 [email protected]
  