| 2021-10-15 15:41:37 | FROM: RAY CARANCI, SENIOR LANDSCAPE PLANNER |
| | 561-822-1462 |
| | PROJECT: 300 BANYAN Z21070018 |
| | OCTOBER 15, 2021 |
| | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND |
| | PROVIDE THE FOLLOWING COMMENTS: |
| | |
| | |
| | 1. MAKE THE FOLLOWING CORRECTIONS TO THE TREE |
| | DISPOSITION PLAN: |
| | ? PARTIALLY SATISFIED. ADD A COLUMN TO THE CHART FOR |
| | MITIGATION SQUARE FOOTAGE DUE AND SHOW THE AMOUNT FOR |
| | EACH TREE PROPOSED TO BE REMOVED. |
| | COLUMN SHOULD BE LABELED MITIGATION DUE, NOT TREE |
| | CREDITS. TREES WITH A CANOPY 20 FEET OR MORE IN |
| | DIAMETER MUST HAVE THE ACTUAL SQUARE FOOTAGE CALCULATED |
| | AND ENTERED ON THE CHART. |
| | ? PARTIALLY SATISFIED. PROVIDE TOTAL OF MITIGATION |
| | SQUARE FOOTAGE DUE. |
| | UPDATE TOTAL WITH MITIGATION RECALCULATED FOR ABOVE. |
| | ? PARTIALLY SATISFIED. PROVIDE A TOTAL OF MITIGATION |
| | SQUARE FOOTAGE PROVIDED BASED ON THE PLANT LIST. |
| | PROVIDE A CHART WITH THE TOTAL FOR EACH SPECIES AND |
| | REMOVE MITIGATION CALCULATIONS FROM SHEET L11, THEY ARE |
| | INCORRECT. TREE CATEGORY LIST MUST BE USED FOR |
| | MITIGATION CREDITS. CATEGORY 1 IS 300 SQ FT CANOPY |
| | CREDIT, CATEGORY 2 IS 150 SQ FT CANOPY CREDIT, CATEGORY |
| | 3 IS 100 SQ FT CANOPY CREDIT, CATEGORY 4 IS 50 SQ FT |
| | CANOPY CREDIT, |
| | |
| | 2. PARTIALLY SATISFIED. SECTION 94-448 (D)(3) REQUIRES |
| | NATIVE TREES IN GOOD CONDITION TO BE PRESERVED ON SITE |
| | OR RELOCATED. ANSI A 300 (PART 5) STANDARDS SPECIFY |
| | EXAMPLES OF SUITABILITY RATINGS OF GOOD, MODERATE, OR |
| | POOR FOR RELOCATION. PROVIDE AN ARBORIST REPORT SHOWING |
| | CONDITION FOR ALL TREES AND RELOCATION POTENTIAL FOR |
| | THE NATIVE TREES. ALL INDIVIDUAL TREES NEED AN ACCURATE |
| | REASON FOR REMOVAL PROVIDED, CANNOT BE A GENERAL |
| | STATEMENT, SO REMOVE THE NOTE. |
| | REMOVE NOTE ON TREE DISPOSITION SCHEDULE SHEET L1A |
| | REGARDING REMOVAL OF TREES AS IT IS NOT ACCURATE OR |
| | RELEVANT. |
| | THE ARBORIST REPORT LISTS ONLY TREE #12 AS GOOD |
| | CONDITION. PROVIDE THE REASON FOR NOT RELOCATING. |
| | |
| | 3. PARTIALLY SATISFIED. PROVIDE A DIAGRAM OF THE |
| | PROVIDED 25% PRIVATE OPEN SPACE AREAS FOR CWD-10. |
| | IDENTIFY THE TYPE OF OPEN SPACE AS ALLOWED BY TABLE |
| | IV-7 AND DEFINITIONS IN SECTION 94-109. SHOW HOW THE |
| | STANDARDS FOR THE TYPES OF OPEN SPACE ARE MET FOR |
| | VEGETATED AREAS AND TREE CANOPY SQUARE FOOTAGE BASED ON |
| | TABLE IV-8. |
| | SHOW EACH TERRACE PRIVATE OPEN SPACE SQUARE FOOTAGE AND |
| | HOW IT INDIVIDUALLY MEETS THE 20% VEGETATED AREA. THEY |
| | CAN SHOW THE TOTAL AREA PROVIDED, BUT EACH SPACE MUST |
| | MEET THE REQUIREMENTS. PROVIDE ALL SQUARE FOOTAGE AND |
| | PERCENTAGE MEASUREMENTS ON SHEET L8A. |
| | |
| | |
| | 4. PARTIALLY SATISFIED. PROVIDE CALCULATIONS FOR |
| | REQUIRED STREET TREES AT ONE FOR EVERY 30 FEET OR |
| | PORTION THEREOF FOR STREETSCAPE LENGTH, AND SHOW THE |
| | NUMBER PROVIDED PER SECTION 94-113 AND 94-116. |
| | STREET TREE CALCULATIONS AND PLAN NEED TO BE PROVIDED. |
| | OLIVE AVE SIDE OF CLEMATIS BUILDING NEEDS TO BE |
| | INCLUDED. REFERENCE THE APPROVED STREETSCAPE PLANS FOR |
| | THE BANYAN STREETSCAPE PROJECT. |
| | PROVIDE THE CALCULATIONS FOR EACH STREETSCAPE LENGTH |
| | FOR BANYAN AND OLIVE ALONG 300 BANYAN AND DIVIDE BY 30 |
| | AND ROUND UP TO SHOW THE REQUIRED NUMBER OF STREET |
| | TREES FOR EACH SIDE. PROVIDE THE NUMBER OF SHADE TREES |
| | FOR EACH SIDE. PALMS MAY NOT BE COUNTED TOWARD SHADE |
| | TREE REQUIREMENT. THERE IS ENOUGH ROOM TO USE LIVE OAKS |
| | FOR ALL REQUIRED STREET TREES. |
| | |
| | 5. PARTIALLY SATISFIED. SHOW THE LOCATIONS OF THE |
| | REQUIRED STRUCTURAL SOIL UNDER HARDSCAPE PER SECTION |
| | 94-113 AND PROVIDE THE TYPICAL DETAIL FOR INSTALLATION. |
| | THE AREA MUST BE 9 X14 FT PARALLEL TO THE CURB FOR EACH |
| | TREE CONSISTING OF PLANTING AREA AND/OR STRUCTURAL |
| | SOIL. |
| | SHOW THE LOCATIONS ON THE LANDSCAPE PLAN. |
| | |
| | 6. SATISFIED. THERE APPEAR TO BE CONFLICTS IN SEVERAL |
| | LOCATIONS BETWEEN PROPOSED STREET TREES AND DRAINAGE |
| | EXFILTRATION LINES ON THE LANDSCAPE PLAN. ADJUST |
| | DRAINAGE LOCATIONS SO THEY DO NOT INFRINGE ON THE |
| | REQUIRED PLANTING AREA OR STRUCTURAL SOIL. |
| | |
| | 7. SATISFIED. SHOW THE LOCATIONS OF ALL UTILITIES ON |
| | THE LANDSCAPE PLAN AND RESOLVE ANY CONFLICTS. |
| | |
| | 8. PARTIALLY SATISFIED. PER SECTION 94-113 TREE GRATES |
| | ARE ONLY TO BE USED IF PLANTING STRIPS ARE NOT |
| | POSSIBLE. PLANTING STRIP WITH PAVER PASS THROUGHS FOR |
| | PARKING SPACE ACCESS ARE WARRANTED ON BANYAN. IF |
| | PARKING IS NOT APPROVED ON BANYAN, PLANTING STRIPS MUST |
| | BE USED. |
| | THE PLANTING AREAS NEED TO BE LENGTHENED ALONG BOTH |
| | STREETS WITH PASS THROUGHS PLACED FOR PEDESTRIAN ACCESS |
| | FROM THE DROP OFFS. |
| | |
| | |
| | 9. PARTIALLY SATISFIED. PROVIDE A COMPLETE PLANT LIST. |
| | PLANT LIST NEEDS TO BE MODIFIED TO SEPARATE THE |
| | REQUIRED OPEN SPACE PLANT LISTS AND THE SEPARATE |
| | BUILDINGS. |
| | |
| | 10. SATISFIED. REMOVE HIGHRISE CULTIVAR AND INDICATE |
| | SPECIES LIVE OAK OR CATHEDRAL LIVE OAK. |
| | |
| | 11. SATISFIED. ADD A COLUMN FOR DROUGHT TOLERANCE LEVEL |
| | TO THE PLANT LIST. |
| | |
| | 12. PARTIALLY SATISFIED. SHOW COMPLIANCE WITH SECTION |
| | 94-445 L. PLANT SPECIES. A MINIMUM OF 60 PERCENT OF |
| | PLANT MATERIAL ADDED SHALL BE FLORIDA NATIVE OR DROUGHT |
| | TOLERANT SPECIES SELECTED FROM THE CITY LIST OR THE |
| | LIST OF SPECIES IN THE MOST RECENT EDITION OF SOUTH |
| | FLORIDA WATER MANAGEMENT DISTRICT WATERWISE SOUTH |
| | FLORIDA LANDSCAPES. PROVIDE THE ACTUAL PERCENTAGE BASED |
| | ON THE PLANT LIST. |
| | REVISE AFTER ALL CHANGES ARE COMPLETE WITH LANDSCAPE |
| | PLAN. |
| | |
| | 13. PARTIALLY SATISFIED. PROVIDE BUFFER REQUIREMENTS ON |
| | THE CHART AND LANDSCAPE PLAN FOR THE WEST AREA OF THE |
| | LOT ADJACENT TO THE PROPERTY LINE. STAFF REQUESTS |
| | ADDING ANY LANDSCAPING SUCH AS HEDGING ALONG THE ALLEY |
| | PROPERTY LINE TO IMPROVE THE ENVIRONMENT. |
| | PROVIDE THE ENTIRE PROPERTY LINE LENGTH FOR THE WEST |
| | BUFFER, DIVIDE BY 30 AND ROUND UP FOR THE REQUIRED |
| | NUMBER OF BUFFER TREES. SHOW THE NUMBER PROVIDED. SABAL |
| | PALMS ARE A 3:1 EQUIVALENT TO A REQUIRED TREE. |
| | |
| | 14. MAKE THE FOLLOWING CORRECTIONS TO THE PLANTING |
| | NOTES ON SHEET L10: |
| | ? SATISFIED. CORRECT TO REMOVE CYPRESS MULCH FROM THE |
| | NOTE, IT IS NOT ALLOWED. |
| | ? SATISFIED. ALL PLANTING AREAS SHALL BE NOTED TO BE |
| | BACKFILLED WITH 50/50 MIX OR SIMILAR TO A DEPTH OF 30 |
| | INCHES. |
| | ? SATISFIED. INDICATE ALL PLANT MATERIAL TO BE GRADE#1 |
| | OR BETTER. |
| | CONDITIONS OF APPROVAL |
| | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON |
| | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE |
| | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT |
| | SERVICES DEPARTMENT, PLANNING DIVISION. |
| | 2. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE |
| | RESPONSIBLE FOR THE PERMITTING AND INSTALLATION OF THE |
| | STREET TREES AND RIGHT OF WAY LANDSCAPING AND |
| | IRRIGATION APPROVED WITH THIS PETITION. |