| Date |
Text |
| 2022-04-13 12:15:35 | 1. AS PER THE CHANGE IN PROJECT SCOPE, STAFF RECOGNIZES |
| | THE DOWNGRADE FROM A MAJOR PD AMENDMENT TO THAT OF A |
| | MINOR PD AMENDMENT, AS THERE ARE NO CHANGES TO TOTAL |
| | SQUARE FOOTAGE OF ANY BUILDINGS OR STRUCTURES ONSITE, |
| | NO CHANGES TO PD BOUNDARIES, OR CHANGES IN PD |
| | CONDITIONS. |
| | |
| | 2. STAFF HAS CONCERNS WITH THE ADDITIONAL DROP-OFF |
| | LOCATION ALONG TRINITY PL. WITHIN PUBLIC LAND. THE |
| | PROPOSED DROP-OFF REQUIRES AND ENCROACHES SIGNIFICANTLY |
| | INTO CITY-OWNED LAND. IT WILL SIGNIFICANTLY IMPACT |
| | GREENSPACE ALONG FLAGLER DR. FOR THE USE OF AN EXTRA |
| | VEHICULAR DROP-OFF. |
| | |
| | CONVEYANCE OR USE OF THE CITY-OWNED LAND FOR THE |
| | DROP-OFF WILL REQUIRE SIGNIFICANT IMPROVEMENTS TO THE |
| | SURROUNDING GREENSPACE AND PUBLIC REALM ALONG BOTH THE |
| | ROW OF TRINITY PL. AND FLAGLER DR. TO COMPENSATE FOR |
| | THE NEGATIVE IMPACT OF THE ADDITIONAL DROP-OFF AREA. |
| | THESE IMPROVEMENTS SHALL INCLUDE ADDITIONAL LANDSCAPING |
| | (STREET TREES, PLANTINGS, ETC.) SEATING, AND PEDESTRIAN |
| | IMPROVEMENTS. |
| | |
| | 3. WITH THE REMOVAL OF THE BUILDING ENTRANCE ON CORNER |
| | OF TRINITY PL. AND CHASE ST., STAFF IS CONCERNED WITH |
| | THE REDUCED CHANCE FOR ACTIVITY ON THE GROUND LEVEL OF |
| | TRINITY PL. WHAT IS GOING ON WITHIN THIS SPACE? |
| | A. SHEET C4.02 SHOWS ENTRANCES ON THE SIDEWALK AND |
| | CORNER SIDE, THESE CANNOT BE ACCESSED FROM THE TRINITY |
| | PL. SIDEWALK. |
| | |
| | 4. "WATER WELL FOR COOLING SYSTEM" VAULT SHOWN IN |
| | SIDEWALK/ROW. NOTE CLAIMS TO PUT THIS VAULT AT GRADE, |
| | PLANS ALSO SHOW 3'-7" OF CLEARANCE ON THE SIDEWALK. |
| | WILL VAULT IMPEDE PEDESTRIAN TRAFFIC ON THE SIDEWALK, |
| | PLEASE CLARIFY? |
| | |
| | 5. END OF DROP-OFF WHERE TRINITY PL. MEETS FLAGLER DR. |
| | WILL REQUIRE AN ALTERATION TO THE EGRESS TO |
| | DISCOURAGE/PREVENT ENTRANCE FROM SOUTHBOUND CARS ALONG |
| | FLAGLER DR. THE TRINITY PL. EXIT REQUIRES SIGNAGE FOR |
| | STRAIGHT AND RIGHT TURN ONLY, WITH THE ADDITION OF A NO |
| | ENTRY SIGN ON FLAGLER DR. |
| | |
| | 6. MINIMUM WIDTH OF TWO-WAY SHALL BE 18'. PLEASE |
| | INCREASE AREA AROUND DROP-OFF TO BE 18' IN WIDTH AT A |
| | MINIMUM PLUS THE SIDE GUTTERS. |
| | |
| | 7. WHAT IS HAPPENING THE WITH FDC CONNECTION WITHIN THE |
| | TRIANGULAR SECTION OF GREENSPACE BETWEEN TRINITY PL. |
| | AND FLAGLER DR.? IS THIS BEING RELOCATED? PLEASE |
| | CLARIFY. |
| | |
| | 8. PLEASE MODIFY OR REALIGN THE EXISTING PEDESTRIAN |
| | PATH FROM TRINITY PARK, ADJUST IT TO BE PERPENDICULAR |
| | TO THE SOUTHERN SIDEWALK ALONG TRINITY PL (MAKING A |
| | MORE DIRECT/SHORTER PEDESTRIAN CROSSING OVER THE |
| | TRAVEL/DROP-OFF LANES). |
| | |
| | 9. ADDITION OF A SIDEWALK ON THE NORTH SIDE OF TRINITY |
| | PLACE WITH ADDITIONAL STREET TREES. |
| | |
| | 10. PLEASE CONFIRM ALL RESTAURANT SEATING IS OUTDOORS, |
| | NOT ENCLOSED, AND NOT UNDER AC. |
| | |
| | 11. IS THE BUILDING COLOR PROPOSED TO BE CHANGED FROM |
| | THE EXISTING PINK? RENDERS SEEM TO SUGGEST CHANGE. |
| | |
| | 12. PLEASE PROVIDE FDOT APPROVAL FOR THE STREETSCAPE |
| | CHANGES ALONG LAKEVIEW AVE. |
| | |
| | 13. A MAINTENANCE AGREEMENT WITH THE CITY SHALL BE |
| | APPROVED ASSIGNING THE APPLICANT, SUCCESSORS, AND |
| | ASSIGNS THE RESPONSIBILITY FOR THE MAINTENANCE OF THE |
| | ENTIRE PLANNED DEVELOPMENT SITE AND THE SUBSEQUENT |
| | PUBLIC RIGHTS-OF-WAY, LANDSCAPING, AND IRRIGATION AS |
| | PART OF THE PROPOSED CHANGES. |
| | |
| | 14. THE PLANTERS SCREENING THE GARAGE FACADE SHALL BE |
| | RESTORED WITH PLANT MATERIAL. |
| | |
| | 15. WILL HAVE TO COORDINATE IN THE FUTURE WITH SPECIAL |
| | EVENTS IN REGARDS TO TRINITY PL. ACCESS AND |
| | CIRCULATION, ESPECIALLY DURING THE PB BOAT SHOW AND |
| | SUNFEST. |
| | |
| | |
| | CHRIS KIMMERLY |
| | [email protected] |
| | 822-1426 |
| | |
| |