| 2021-11-05 13:50:10 | THE FOLLOWING COMMENTS ARE FROM THE REVIEW OF THE |
| | OCTOBER 29, 2021 PLAN SUBMITTAL. |
| | |
| | 1. [CONDITION OF SITE PLAN APPROVAL - COORDINATE THE |
| | GRADING OF CURRIE CRESCENT WITH THE FORTE RESIDENCES |
| | DEVELOPMENT.] PROPOSED GRADES AT EAST CURB OF CURRIE |
| | CRESCENT AT THE INTERFACE BETWEEN THE 9/8/21 FORTE |
| | RESIDENCES GRADING PLAN AND THE 9/13/21 FLAGLER TOWERS |
| | GRADING PLAN APPEAR TO MATCH. [SEE NEW COMMENT 31 |
| | BELOW] |
| | |
| | 2. [SATISFIED] FLAGLER TOWERS GRADING PLAN SHOWS A SPOT |
| | GRADE OF 11.07 AT THE PROPOSED SANITARY SEWER MANHOLE. |
| | THIS GRADE WILL CAUSE WATER TO POND IN THE DRIVEWAY |
| | GUTTER TO THE NORTH (WHICH HAS SPOT GRADES OF 10.93 ON |
| | THE SOUTH SIDE AND 11.18 ME ON THE NORTH SIDE OF THE |
| | DRIVEWAY APRON. |
| | |
| | 3. [SATISFIED] MAINTAIN CROWN CROSS SECTION OF CURRIE |
| | CRESCENT. |
| | |
| | 4. [SATISFIED] REQUESTED DIMENSIONS WERE ONLY PROVIDE |
| | FOR SECTIONS B-B, C-C, D-D, H-H, AND J-J. PREVIOUS |
| | COMMENT: FOR THE CROSS SECTIONS ON SHEET C-501, PROVIDE |
| | DIMENSIONS FROM PROPERTY LINE/RIGHT OF WAY LINE TO |
| | VALLEY GUTTER OR BACK OF SIDEWALK. |
| | |
| | 5. [SATISFIED] SIDEWALK ACROSS WEST DRIVEWAY TO CURRIE |
| | CRESCENT SHALL SLOPE TOWARD THE STREET. THE HIGH POINT |
| | OF THE DRIVEWAY SHALL BE SUFFICIENT TO PREVENT |
| | STORMWATER RUNOFF FROM THE RIGHT OF WAY FROM FLOWING |
| | DOWN THE DRIVEWAY TOWARD THE BUILDING AND AT THE SAME |
| | TIME MINIMIZE THE AREA OF THE DRIVEWAY SLOPING TOWARD |
| | THE ROAD (I.E. MAXIMIZE THE DRIVEWAY SLOPE BETWEEN THE |
| | HIGH POINT AND THE BACK OF THE SIDEWALK.)] SUGGEST |
| | SLOPING THE SIDEWALK PORTION OF THE DRIVEWAY SHOWN IN |
| | SECTION B-B TOWARD THE VALLEY GUTTER. THE GRADES SHOWN |
| | ON SHEET C-500 FOR THE DRIVEWAY WITH SECTION B-B (10.72 |
| | AT EP AND 10.70/10.84 AT BOW ACROSS DRIVEWAY) DO NOT |
| | MATCH THE GRADES SHOWN ON SECTION B-B ON SHEET C-501 |
| | (11.00 AT EP AND 11.04 AT BACK OF CROSSWALK [HIGH POINT |
| | OF DRIVEWAY]). SECTION B-B SHOWS LESS THAN 1/2 INCH |
| | DROP (0.04 FT) BETWEEN BACK OF WALK AND EP. THIS SHORT |
| | RISE WILL NOT STOP MUCH ROADWAY STORMWATER RUNOFF FROM |
| | FLOWING DOWN THE DRIVEWAY. THE GRADING PLAN DOESN?T |
| | APPEAR TO SUPPORT ALL OF THE CROSSWALK/SIDEWALK SLOPING |
| | TOWARD THE ROAD. |
| | |
| | 6. [SATISFIED - SLOPES REMOVED FROM SHEET G-203.] |
| | PREVIOUS COMMENT: SECTION D-D SHOWS 13.5% SLOPE EAST OF |
| | THE PROPERTY LINE. SHEET G-203 SHOWS 7.5% RAMP UP. |
| | PREVIOUS COMMENT: COORDINATE THE SLOPES SHOWN FOR THE |
| | DRIVEWAYS WITH THE ARCHITECTURAL PLANS. FOR EXAMPLE, |
| | SECTION C-C SHOWS 3.4% SLOPE BETWEEN THE BUILDING AND |
| | VALLEY GUTTER. SHEET A-101 SHOWS THE DRIVEWAY AT 7.5% |
| | SLOPE. |
| | |
| | 7. [SATISFIED] SECTION D-D: PROVIDE SIDEWALK AREA WITH |
| | SLOPE NO STEEPER THAN 2%. |
| | |
| | 8. [SATISFIED] SECTION E-E: CORRECT LABELS FOR ROAD |
| | CENTERLINE AND PROPERTY LINE. |
| | |
| | 9. [SATISFIED] [CONDITION OF SITE PLAN APPROVAL - |
| | PARALLEL PARKING SPACES ON DIANA PLACE SHALL SLOPE TO |
| | THE PROPOSED NORTH TYPE 'D' CURB AT MINIMUM 2% CROSS |
| | SLOPE. LANDSCAPE AREA BETWEEN BACK CURB AND 10 FT |
| | SIDEWALK SHALL HAVE 4:1 OR FLATTER SLOPE. THE 6.8 FT |
| | LONG SIDEWALK CONNECTORS BETWEEN 10 FT WIDE SIDEWALK |
| | AND THE PROPERTY LINE CAN SLOPE UP TO 7.2% (EQUATES TO |
| | LESS THAN 0.5 FT DROP) WITHOUT NEEDING HANDRAILS. |
| | DRAINAGE STRUCTURE AND STORM PIPE WILL BE NEEDED AT |
| | EAST END OF PARALLEL PARKING SPACES TO COLLECT |
| | STORMWATER RUNOFF AND CONVEY TO EXISTING DRAINAGE |
| | STRUCTURE.] (PREVIOUS COMMENT- GRADING OF THE AREA |
| | BETWEEN THE SOUTH PROPERTY LINE AND THE CENTER LINE OF |
| | DIANA PLACE CAN BE A CONDITION OF SITE PLAN APPROVAL TO |
| | BE WORKED OUT DURING ENGINEERING PERMIT SUBMITTAL.] |
| | REVISED COMMENT: THE GRADING BETWEEN THE ROAD |
| | CENTERLINE AND R/W, AS SHOWN ON SECTIONS H-H THROUGH |
| | J-J NEEDS FURTHER REFINEMENT. SINCE STEPS ARE BEING |
| | PROPOSED TO MAKE UP THE VERTICAL DISTANCE BETWEEN THE |
| | FINISHED FLOORS OF THE HOUSING UNITS AND THE DIANA |
| | PLACE PARCEL, MAINTAIN NORMAL CROWN FOR DIANA PLACE AND |
| | SLOPE THE PARKING TOWARD THE PROPOSED CURB LINE. FOR |
| | SECTION J-J, THE LANDSCAPE AREA SHOULD MEET THE TOP OF |
| | CURB. FOR SECTION J-J, SLOPE THE SIDEWALK TOWARD THE |
| | ROAD AND INSTALL A CATCH BASIN IN THE SMALL LANDSCAPE |
| | AREA AND CONNECT INTO THE CURB INLET ON THE STREET. |
| | PROVIDE SECTION(S) ON EITHER SIDE OF THE STEPS TO SHOW |
| | HOW THE AREA BETWEEN THE STEPS WILL SLOPE. |
| | |
| | 10. [SATISFIED] IT APPEARS THE TOWNHOME AT THE WEST END |
| | OF THE PROJECT WILL HOLD WATER BEHIND THE DIANA PLACE |
| | SIDEWALK. |
| | |
| | 11. [SATISFIED] PROVIDE A CROSS SECTION FROM THE NORTH |
| | PROPERTY LINE TO THE FACE OF THE BUILDING INCLUDING |
| | DIMENSIONS TO THE OUTSIDE OF THE UNDERGROUND PARKING |
| | GARAGE. |
| | |
| | 12. [SATISFIED - CONDITION OF ENGINEERING PERMIT |
| | APPROVAL - FOR THE EXFILTRATION TRENCH ALONG THE NORTH |
| | PROPERTY LINE, THE SFWMD TRENCH EQUATION WILL HAVE TO |
| | BE MODIFIED TO ACCOUNT FOR THE RETAINING WALL ON ONE |
| | SIDE AND POSSIBLE GARAGE WALL ON THE OTHER THAT WILL |
| | LIMIT THE FLOW OUT OF THE TRENCH.] |
| | |
| | 13. [SATISFIED] EXPLAIN HOW THE EXFILTRATION TRENCH |
| | ALONG THE NORTH PROPERTY LINE WILL BE MAINTAINED, |
| | INCLUDING POSSIBLE REPLACEMENT, WHEN IT HAS LOST ITS |
| | DISPOSAL CAPACITY IN A FEW YEARS. |
| | |
| | 14. [NOT SATISFIED. CONDITION OF ENGINEERING PERMIT |
| | APPROVAL - PROVIDE AN EXFILTRATION TRENCH DETAIL, |
| | LABELING THE TRENCH WIDTH AND THE ELEVATIONS FOR THE |
| | TOP OF TRENCH, THE BOTTOM OF THE TRENCH, AND THE PIPE |
| | INVERT.] |
| | |
| | 15. [NOT SATISFIED. CONDITION OF ENGINEERING PERMIT |
| | APPROVAL - PROVIDE DETAIL OF CONTROL STRUCTURE(S). NOTE |
| | BLEEDERS CANNOT BE USED AS PART OF THE CONTROL TO |
| | SURCHARGE THE EXFILTRATION TRENCH.] |
| | |
| | 16. [SATISFIED] SHOW MILL AND RESURFACING LIMITS ON |
| | CURRIE CRESCENT (BECAUSE OF THE TRENCH CUTS AND THE |
| | CHANGE IN PAVEMENT MARKINGS FOR THE PARKING SPACES). |
| | PREVIOUS COMMENT: SHOW MILL AND RESURFACING LIMITS FOR |
| | TRENCH CUTS IN THE ROADWAY PER CITY'S STANDARD DETAIL |
| | GC-8. |
| | |
| | 17. [SATISFIED] CONVERT EXISTING DRAINAGE STRUCTURE IN |
| | THE EXISTING SOUTH DRIVEWAY TO S. FLAGLER DRIVE TO A |
| | CATCH BASIN WITH A HOODED FRAME AND GRATE. THE |
| | STRUCTURE MAY NEED TO BE ENLARGED IN ORDER TO CONNECT |
| | THE PROPOSED 15-INCH RCP FROM THE DEVELOPMENT. |
| | |
| | 18. [SATISFIED - CONDITION OF ENGINEERING PERMIT |
| | APPROVAL - DRAINAGE SYSTEM DESIGN TO CONSIDER SEA LEVEL |
| | RISE.] |
| | |
| | 19. [SATISFIED - PIPE WAS REMOVED] WHAT IS THE PURPOSE |
| | OF THE 6-INCH HDPE PIPE BETWEEN THE SIDEWALK AND EAST |
| | PROPERTY LINE? |
| | |
| | 20. [SATISFIED. CONDITION OF ENGINEERING PERMIT |
| | APPROVAL - THE ROOF DRAIN SYSTEM WILL NEED TO BE |
| | DESIGNED SO THAT MANHOLE LIDS ARE NOT DISPLACED BY THE |
| | PRESSURE OF THE WATER OR TRAPPED AIR IN THE ROOF |
| | DOWNSPOUTS.] |
| | |
| | 21. [SATISFIED] IT APPEARS THE TOWNHOME AT THE WEST END |
| | OF THE PROJECT WILL HOLD WATER BEHIND THE DIANA PLACE |
| | SIDEWALK. |
| | |
| | 22. [SATISFIED - WATER QUALITY TREATMENT PER SFWMD ERP |
| | SHALL BE DESIGNED AND PROVIDED FOR THE ADDITIONAL |
| | IMPERVIOUS AREA IN THE DIANA PLACE PARCEL.] NEW COMMENT |
| | ? FINAL LAYOUT AND DESIGN OF DRAINAGE SYSTEMS ON DIANA |
| | PLACE TO BE WORKED OUT DURING ENGINEERING PERMIT |
| | SUBMITTAL. |
| | |
| | 23. [SATISFIED - DRAINAGE SYSTEM SHOWN ON THE RECENTLY |
| | SUBMITTED FORTE RESIDENCES PLANS.] SHEET C-500 SHOWS |
| | PROPOSED STORM PIPE ALONG THE NORTH CURB OF CURRIE |
| | CRESCENT AND CATCH BASINS NEAR THE EAST END OF THE |
| | STREET BUT NO INFORMATION IS PROVIDED FOR THESE. THE |
| | SIDEWALK AND CURB SHOULD BE SHOWN TO BE REPLACED AND |
| | PROPOSED ASPHALT PAVEMENT IN THE WESTBOUND LANE OF |
| | CURRIE CRESCENT FOR THE STORM PIPE AND ON S. OLIVE AVE |
| | FOR THE DRAINAGE MANHOLE. THE CURB RAMP ON THE NE |
| | CORNER OF S. OLIVE AND CURRIE CRESCENT WILL NEED TO BE |
| | CONSTRUCTED TO CURRENT ADA CRITERIA. |
| | |
| | 24. SATISFIED - GRADES MODIFIED] FOR THE NORTH DRIVEWAY |
| | TO CURRIE CRESCENT, SHEET C-500 SHOWS SPOT GRADES OF |
| | 10.92 AND 10.60+/-ME FOR THE EDGE OF PAVEMENT NEXT TO |
| | THE DROP CURB/VALLEY GUTTER. CROSS SECTION D-D PROVIDES |
| | A SPOT GRADE OF 11.07 FOR THE EP NEXT TO THE DROP |
| | CURB/VALLEY GUTTER. |
| | |
| | 25. [SATISFIED - SPOT GRADES REMOVED FROM ARCHITECTURAL |
| | PLANS] SECTION D-D ON SHEET C-500 SHOWS A SPOT GRADE OF |
| | 11.86 AT THE PROPERTY LINE. SHEETS G-201 AND G-203 SHOW |
| | A SPOT GRADE OF 11FT 3IN AT THE PROPERTY LINE. |
| | |
| | 26. [SATISFIED - SPOT GRADES REMOVED FROM ARCHITECTURAL |
| | PLANS] AT THE NORTH DRIVEWAY TO S. FLAGLER DRIVE, SHEET |
| | C-500 SHOWS THE PROPERTY LINE AT AN ELEVATION LESS THAN |
| | 3.98 FT NAVD. SHEET G-203 SHOWS AN ELEVATION OF 4FT 3IN |
| | AT THE PROPERTY LINE CROSSING THE DRIVEWAY. |
| | |
| | 27. [SATISFIED] - GRADES FOR CROSS SECTIONS SHOWN ON |
| | SHEET C-501 SHALL AGREE WITH THE GRADING PLAN ON SHEET |
| | C-500. |
| | A. SECTION B-B SHOWS EP GRADE OF 11.00; GRADING PLAN |
| | SHOWS SPOT GRADE OF 10.72. |
| | B. SECTION C-C SHOWS BACK OF GUTTER ELEVATION OF 11.18; |
| | GRADING PLAN SHOWS EP SPOT GRADE OF 10.72. |
| | C. SECTION D-D SHOWS SPOT GRADE OF 11.83 AT THE |
| | PROPERTY LINE/FRONT OF TRENCH DRAIN; GRADING PLAN CALLS |
| | OUT TRENCH DRAIN RIM ELEVATION OF 12.90. |
| | D. SECTIONS H-H, I-I AND J-J TO BE MODIFIED PER COMMENT |
| | NO. 9. |
| | |
| | 28. CONSIDER MOVING THE CONTROL STRUCTURE OUT OF THE |
| | SIDEWALK BETWEEN S. OLIVE AVE AND THE RESTAURANT/CAFE. |
| | |
| | 29. FORTE RESIDENCES DEVELOPMENT WAS INSTRUCTED TO MOVE |
| | THE 5 FT WIDE SIDEWALK ON THE NORTH SIDE OF CURRIE |
| | CRESCENT TO THE NORTH R/W LINE. THIS WILL REDUCE THE |
| | WIDTH OF THE ROAD AND MAY IMPACT THE AUTOTURN ANALYSES |
| | FOR FLAGLER TOWERS. |
| | |
| | 30. [SATISFIED] THE FRAME AND COVER OF THE PROPOSED |
| | SANITARY SEWER MANHOLE WHERE CURRIE CRESCENT TURNS |
| | NORTH SHALL NOT BE WITHIN THE CURB AND GUTTER. THE RIM |
| | ELEVATION FOR THIS STRUCTURE (10.43) DOES NOT MATCH THE |
| | GRADING PLAN (11.07). |
| | |
| | NEW COMMENTS: |
| | 31. FORTE RESIDENCES? EOR TO JUSTIFY THE PROPOSED CROSS |
| | SLOPES OF CURRIE CRESCENT OR FLATTEN THEM TO MEET THE |
| | FLORIDA GREEN BOOK. |
| | |
| | 32. TYPE 'C' DETAIL HAS NOTE THAT WEIRS OR PRBS ARE NOT |
| | TO BE USED IN THIS TYPE OF STRUCTURE. THERE IS A |
| | PROPOSED TYPE 'C' INLET WITH PRB CALLED OUT IN THE |
| | NORTH FRONTAGE ALONG S. OLIVE AVE. [CAN BE ADDRESSED |
| | WITH ENGINEERING PERMIT SUBMITTAL] |
| | |
| | 33. SHOW SWALE WHERE THE TOP OF CURB ELEVATION IS |
| | HIGHER THAN THE FRONT OF WALK ELEVATION ALONG DIANA |
| | PLACE (NEAR WEST END OF THE PARALLEL PARKING SPACES). |
| | [CAN BE ADDRESSED WITH ENGINEERING PERMIT SUBMITTAL] |
| | |
| | |
| | TRACY WARD, PE |
| | SENIOR STORMWATER ENGINEER |
| | ENGINEERING SERVICES DEPARTMENT |
| | 561-494-1120 (O) |
| | 561-351-0510 (M) |
| | [email protected] |
| | |
| |