| Date |
Text |
| 2021-07-26 17:14:29 | CASE NO. PB 1857B -1ST RESUBMITTAL REVIEW |
| | FLAGLER TOWERS |
| | 1315 SOUTH FLAGLER DRIVE |
| | |
| | - CONTACT ERIC SCHNEIDER @ (561) 822-1446, |
| | [email protected] |
| | |
| | - PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN |
| | WRITTEN FORMAT. |
| | |
| | - WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF THREE |
| | (3) PAPER COPIES AND AN ELECTRONIC COPY IN .PNG FORMAT |
| | OF ALL PLANS. PLEASE NOTE THAT CHANGES ON THE |
| | RESUBMITTED PLANS OR THE SUBMITTAL OF INFORMATION/PLANS |
| | TO ADDRESS THE COMMENTS MAY RESULT IN ADDITIONAL |
| | COMMENTS. |
| | |
| | - THE PPRC COMMENTS SHALL BE SUFFICIENTLY ADDRESSED AND |
| | SUBMITTED TO THE PLANNING DIVISION BY 5 PM ON FRIDAY, |
| | JULY 30, 2021, TO BE ELIGIBLE TO BE SCHEDULED FOR THE |
| | SEPTEMBER 21, 2021 PLANNING BOARD MEETING. |
| | |
| | - PLEASE NOTE THAT IF THE PLANNING DIVISION HAS NOT |
| | RECEIVED A RESPONSE TO THE COMMENTS WITHIN 60 DAYS FROM |
| | THE DATE OF ISSUANCE (BY AUGUST 10, 2021), THE PLANNING |
| | DIVISION MAY NOTIFY THE APPLICANT THAT THE CASE IS |
| | CONSIDERED WITHDRAWN. ANY FURTHER ACTION SHALL REQUIRE |
| | A NEW DEVELOPMENT APPLICATION. |
| | |
| | - PLEASE NOTE THAT YOU WILL BE ASSESSED A RESUBMITTAL |
| | FEE. SUCH FEE IS 20% OF THE ORIGINAL APPLICATION FEE |
| | ($600). |
| | |
| | - PUBLIC HEARING NOTIFICATION SIGNAGE SHALL BE POSTED |
| | IN ACCORDANCE WITH THE REQUIREMENTS OF SECTION |
| | 94-39(I)(5) OF THE ZONING AND LAND DEVELOPMENT |
| | REGULATIONS. |
| | |
| | 1) REPEAT COMMENT: THANK YOU FOR PROVIDING THE TRAFFIC |
| | STUDY THAT STATES THAT THE PROJECT DOES NOT GENERATE A |
| | SIGNIFICANT IMPACT. HOWEVER, YOU ARE STILL REQUIRED TO |
| | PROVIDE A PALM BEACH COUNTY TPS APPROVAL LETTER. |
| | |
| | 2) UPDATED COMMENT: STAFF DOES NOT OBJECT TO THE |
| | PROPOSED SIDEWALK AND WALKWAYS TO THE TOWNHOUSE UNITS |
| | BEING INSTALLED AND THE TREES BEING REPLACED ON THE |
| | CITY OWNED PARCEL SOUTH OF THE PROJECT. THE PARCEL IS |
| | SUBJECT TO A DEED RESTRICTION. IN ORDER TO ENSURE THAT |
| | THE PROPOSED CHANGES DO NOT IMPACT THE DEED |
| | RESTRICTION, PRIOR TO SCHEDULING THE APPLICATION FOR |
| | THE PLANNING BOARD MEETING, YOU MUST PROVIDE WRITTEN |
| | CONSENT/NO OBJECTION FROM THE LAKE WORTH PIONEERS |
| | ASSOCIATION AND THE NORTON GALLERY AND SCHOOL OF ART, |
| | INC., TO THE CITY. |
| | |
| | 3) REPEAT COMMENT: THANK YOU FOR PROVIDING THE FAA |
| | APPLICATION NUMBERS. YOU ARE REQUIRED TO SUBMIT THE FAA |
| | APPROVAL FOR THE PROPOSED TOWER PRIOR TO SCHEDULING |
| | THIS CASE FOR PLANNING BOARD. |
| | |
| | 4) REPEAT COMMENT: STAFF WILL NOT SUPPORT THE BUILDING |
| | IN EXCESS OF 300 FEET IN HEIGHT. PLEASE NOTE THAT YOU |
| | ARE WELCOME TO PROCEED THROUGH THE PUBLIC HEARING |
| | PROCESS TO CITY COMMISSION; HOWEVER, STAFF WILL BE |
| | RECOMMENDING DENIAL OF THE REQUEST AS CURRENTLY |
| | PROPOSED. THE LATEST ROUND OF RESPONSES INCLUDES ITEMS |
| | WHICH MUST BE PROVIDED AND CORRECTED PRIOR TO BEING |
| | SCHEDULED FOR PLANNING BOARD, REGARDLESS OF THE |
| | BUILDING DESIGN (EXAMPLE: PARKING LOT CORRECTIONS). |
| | |
| | BUILDING PLACEMENT |
| | |
| | 5) STAFF HAS REASSESSED THE MEASURE POINTS TO DETERMINE |
| | BASIS FOR THE NORTHERN SETBACK WAIVERS. LEVEL WILL BE |
| | 15 FEET, LEVELS 2 THROUGH 4 (PODIUM) WILL BE 41 FEET |
| | AND THE NORTHERN TOWER WILL BE 41 FEET. |
| | |
| | 6) THANK YOU FOR PROVIDING THE TWO CROSS SECTIONS EAST |
| | OF THE RESIDENT ENTRANCE ALONG DIANA PLACE. PLEASE |
| | PROVIDE ONE THAT INCLUDES THE ANGLED PARKING SPACES AND |
| | ONE THAT INCLUDES THE EASTERNMOST TOWNHOUSE SO THAT |
| | STAFF CAN SEE WHAT THE IMPACT OF CHANGING THE GRADE HAS |
| | AT THESE TWO LOCATIONS. |
| | |
| | 7) STAFF HAS REVIEWED THE RESPONSE TO THE COMMENT |
| | REGARDING PUSHING THE SOUTHERN TOWER BACK FROM THE |
| | FACADE OF THE PODIUM. PROVIDE A CONTEXT ELEVATION FROM |
| | SOUTH FLAGLER DRIVE FACING EAST WHICH SHOWS HOW THE |
| | PROPOSED BUILDING INTERACTS WITH THE PARK AND THE |
| | NORTON MUSEUM. STAFF HAS INCLUDED THE VIEWPOINT IN THE |
| | COMMENT ADDENDUM SENT AS A SEPARATE FILE. |
| | |
| | 8) UPDATED COMMENT: THANK YOU FOR CLARIFYING THAT THE |
| | FIVE (5) FOOT BALCONY ENCROACHMENT IS ONLY ON LEVEL 26 |
| | AND 27. THIS WILL BE THE SPECIFIC WAIVER. STAFF WILL |
| | NOT SUPPORT A BLANKET WAIVER FOR ALL THE BALCONIES ON |
| | THE SOUTH FA?ADE TO EXTEND FIVE (5) FEET FROM THE |
| | BUILDING SINCE THIS IS NOT HOW THE DRAWINGS ARE BEING |
| | PRESENTED. THE WEST COLOR ELEVATION FAILS TO SHOW THE |
| | BALCONY. THE ELEVATION DRAWINGS MUST MATCH THE FLOOR |
| | PLANS. |
| | |
| | 9) PROVIDE THE DEPTH OF THE TERRACE ON THE SOUTH SIDE |
| | OF THE TOWER ON LEVEL 10. THIS TERRACE ENCROACHES |
| | FURTHER INTO THE SOUTHERN SETBACK THAN THE OTHER |
| | TERRACES FOR WHICH DIMENSIONS WERE PROVIDED. |
| | |
| | 10) PROVIDE THE DEPTH OF THE TRELLIS FEATURES THAT |
| | OVERHANG THE BUILDING EDGES. |
| | |
| | 11) UPDATED COMMENT: EVEN THOUGH THE CANOPY AT THE |
| | SOUTH ENTRANCE WAS REDUCED IN SIZE, IT STILL INTERFERES |
| | WITH THE SPECIMEN OAK TREE THAT IS BEING PROPOSED AT |
| | THIS LOCATION. THE 10-FOOT DEPTH WILL INTERFERE WITH |
| | ANY TREE INSTALLED AS SHOWN. |
| | |
| | 12) PROVIDE THE HEIGHTS OF THE CANOPIES AND AWNINGS |
| | FROM GRADE. |
| | |
| | 13) REPEAT COMMENT: THE SITE OPEN SPACE IS INCORRECTLY |
| | CALCULATED. THE AREAS SUCH AS THE MOTOR COURT AND THE |
| | DRIVE WHERE IT IS ABOVE THE FIRST LEVEL OF THE BUILDING |
| | IS NOT OPEN SPACE IT IS THE BUILDING ROOF OF THE |
| | FIRST-FLOOR PARKING. |
| | |
| | 14) WHAT DOES THE 3-FOOT SETBACK ENCROACHMENT NOTE AT |
| | THE FLAGLER DRIVE DRIVEWAY ENTRANCE REFER TOO? |
| | |
| | 15) WHAT OCCURS IN THE ROOM BEHIND THE TERRACE TO THE |
| | WEST OF THE FLAGLER DRIVE RESIDENT PARK? IS THERE AN |
| | OPPORTUNITY TO HAVE THIS AS A ROOM THAT RESIDENTS CAN |
| | USE TO ENTERTAIN AS IT OVERLOOKS THE TERRACE AND THE |
| | PARK? IS THERE AN OPPORTUNITY TO HAVE WINDOWS? SEE |
| | ADDENDUM FOR LOCATION. |
| | |
| | 16) THE SIDEWALK ALONG FLAGLER DRIVE WHERE IT MEETS |
| | FORTE MUST BE THE SAME WIDTH AS THE SIDEWALK THAT FORTE |
| | IS INSTALLING, NOT FIVE FEET AS PROPOSED. THIS NEEDS TO |
| | BE CLEARLY SHOWN ON THE PLANS. |
| | |
| | 17) EXPLAIN THE ENTRANCES TO THE TOWNHOUSES. ONE UNIT |
| | APPEARS TO HAVE TWO MAIN ENTRANCES AND OTHERS SEEM TO |
| | HAVE THE INTERNAL WALKWAYS THAT CROSS BETWEEN UNIT |
| | COURTYARDS. PROVIDE ACCURATE CONFIGURATIONS. SEE |
| | ADDENDUM FOR LOCATION. |
| | |
| | ELEVATIONS |
| | |
| | 18) PROVIDE THE ELEVATION DIMENSION LINES ON THE ACTUAL |
| | ELEVATION DRAWINGS. THE STACKING DIAGRAM DOES NOT |
| | PROVIDE THE DETAILS THAT ARE SHOWN ON THE ELEVATIONS. |
| | |
| | 19) THE EAST ELEVATION AT THE PARK IS NOT ACCURATE. THE |
| | PARKING RAMP NOT SHOWN, AND THE DOORS AND WALLS DO NOT |
| | SEEM ACCURATE WHEN COMPARED TO THE SITE AND LANDSCAPE |
| | PLANS. |
| | |
| | PARKING |
| | |
| | 20) THE PROJECT NOW CONTAINS EXCESS PARKING SPACES; |
| | HOWEVER, STAFF REQUIRES A BETTER DESCRIPTION OF HOW THE |
| | SPACES IN EACH GARAGE WILL BE ACCESSED AND WHO HAS |
| | ACCESS TO THE SPACES (VALET VS. SELF-PARK). UNTIL STAFF |
| | HAS A FULL UNDERSTANDING OF HOW THE PARKING WILL |
| | FUNCTION, WE ARE UNABLE TO GIVE AN ANSWER TO YOUR |
| | QUESTION, "CAN WE COUNT THE TANDEM SPACES ON THE SECOND |
| | GARAGE LEVEL TOWARDS MEETING OUR CODE REQUIREMENT IF WE |
| | PROVIDE A VALET PARKING PLAN AND THE SPACES ARE USED |
| | FOR VALETING THE STAFF, VISITORS, AND CAFE PARKING?" |
| | PLEASE PROVIDE A BREAKDOWN LIKE THE TABLE PROVIDED IN |
| | THE ADDENDUM. NOTE: IT DOES NOT NEED TO REPLACE ANY |
| | TABLES YOU CURRENTLY PROVIDE. |
| | |
| | 21) REPEAT COMMENT: WHERE ARE THE GUEST PARKING SPACES |
| | AND HOW ARE THEY ACCESSED (ARE THEY REQUIRED TO BE |
| | VALET OR MAY THEY SELF-PARK)? THE 11 REQUIRED GUEST |
| | PARKING SPACES MUST BE LABELED ON THE ON THE PLANS. |
| | |
| | 22) ADDITIONAL ADA COMMENTS FROM ROBERT BROWN REGARDING |
| | THE SECOND LEVEL PARKING (ONLY AS CAFE CUSTOMERS) AND |
| | GUEST PARKING: |
| | |
| | A. SINCE A TOTAL OF 67 PARKING SPACES ARE BEING |
| | PROVIDED EXCLUSIVELY FOR CAFE CUSTOMERS, NO MATTER |
| | WHETHER THOSE ARE SELF-PARKING OR VALET, 3 ACCESSIBLE |
| | PARKING SPACES MUST BE PROVIDED FOR CAF? CUSTOMERS AND |
| | THE USERS MUST BE ABLE TO SELF-PARK IF THEY WANT TO. |
| | THEIR VEHICLE MAY HAVE BEEN MODIFIED TO THE POINT WHERE |
| | A VALET CANNOT OPERATE IT. |
| | B. SINCE THE SPACES ARE EXCLUSIVELY FOR CAFE CUSTOMERS, |
| | ONE OF THE ACCESSIBLE SPACES MUST BE VAN ACCESSIBLE. |
| | C. THE USERS OF THE ACCESSIBLE PARKING SPACES MUST BE |
| | ABLE TO SELF-PARK IF THEY WANT TO. THEIR VEHICLE MAY |
| | HAVE BEEN MODIFIED TO THE POINT WHERE A VALET CANNOT |
| | OPERATE IT. |
| | D. WHEN THE GUEST PARKING SPACES ARE DESIGNATED ON THE |
| | PLANS, IF THEY ARE EXCLUSIVELY FOR GUESTS, THEY MUST |
| | INCLUDE ACCESSIBLE AND VAN ACCESSIBLE PARKING IN |
| | NUMBERS ACCORDING TO HOW MANY PARKING SPACES ARE |
| | DESIGNATED EXCLUSIVELY FOR GUEST PARKING. |
| | |
| | 23) THE COMMENT RESPONSE STATES THAT THE LEVEL 3 |
| | PARKING AREA IS ONLY FOR RESIDENTS. DOES THIS MEAN THAT |
| | THIS IS A SELF-PARK ONLY PARKING AREA? |
| | |
| | 24) TANDEM PARKING SPACES ARE SHOWN ON LEVEL 3. WHO |
| | USES THESE TANDEM SPACES? |
| | |
| | 25) ON THE RESIDENT PARKING LEVELS, DO UNIT OWNERS OWN |
| | DESIGNATED PARKING SPACES? |
| | |
| | 26) REPEAT COMMENT: THE ADA PARKING SPACE DETAIL |
| | (ACCESSIBLE AND VAN ACCESSIBLE) ON SHEET A-054 DO NOT |
| | CONFORM TO CITY STRIPING STANDARDS. IF YOU REQUIRE THE |
| | CITY STANDARD DETAIL, PLEASE LET STAFF KNOW AND IT WILL |
| | BE PROVIDED. |
| | |
| | PARKING COUNTS: |
| | |
| | 27) SHEET A-100 BASEMENT LEVEL - CORRECT THE ERRORS |
| | IDENTIFIED BELOW: |
| | |
| | A. THE TABLE LISTS 168 TOTAL PARKING SPACES, YET THE |
| | PARKING TAGS SHOW 169 PARKING SPACES, WHICH VERIFIES |
| | STAFF'S COUNT OF THE NUMBER OF PARKING SPACES. |
| | THERE ARE ONLY 14 COMPACT SPACES PROVIDED, NOT 15 AS |
| | STATED IN THE TABLE. |
| | THERE ARE 147 STANDARD PARKING SPACES PROVIDED, NOT 145 |
| | AS STATED IN THE TABLE. |
| | |
| | B. THE PARKING BY TYPE TABLE LISTS 277 STANDARD PARKING |
| | SPACES, YET STAFF HAS COUNTED 325 STANDARD PARKING |
| | SPACES. |
| | |
| | 28) SHEET A-102 LOBBY LEVEL - CORRECT THE ERRORS |
| | IDENTIFIED BELOW: |
| | |
| | A. THE TABLE LISTS 43 TOTAL PARKING SPACES, YET STAFF |
| | HAS COUNTED 68 PARKING SPACES. |
| | THERE ARE 42 STANDARD PARKING SPACES PROVIDED, NOT 17 |
| | AS STATED IN THE TABLE. |
| | |
| | B. THE BACK-UP DISTANCE BETWEEN SPACES 325 AND 344 ON |
| | LEVEL 2 PARKING DOES NOT CONTAIN THE CODE MINIMUM 24 |
| | FEET AISLE, SO ONE OF THE SPACES MUST BE REMOVED (OR |
| | CONVERTED TO A COMPACT SPADE). |
| | |
| | 29) SHEET A-103 LEVEL 3 - CORRECT THE ERRORS IDENTIFIED |
| | BELOW: |
| | |
| | A. THE TABLE LISTS 62 TOTAL PARKING SPACES, YET STAFF |
| | HAS COUNTED 84 PARKING SPACES. |
| | THERE ARE 61 STANDARD PARKING SPACES PROVIDED, NOT 40 |
| | AS STATED IN THE TABLE. |
| | THERE IS 1 COMPACT PARKING SPACE PROVIDED THAT IS NOT |
| | ACCOUNTED FOR IN THE TABLE. |
| | |
| | B. THE PARKING SPACE NUMBERING ON SHEET A-103 STARTS AT |
| | 351 INSTEAD OF 347 (NEXT NUMBER IN SEQUENCE FROM SHEET |
| | A-102) AND THUS THE BUILDING IS SHOWN TO HAVE 434 |
| | PARKING SPACES, WHICH IS NOT ACCURATE. |
| | |
| | 30) THERE ARE 430 TOTAL PARKING SPACES SHOWN ON THE |
| | PLANS (INCLUDES 49 TANDEM SPACES). NOTE: THE VARIOUS |
| | TABLES ALTERNATE BETWEEN COUNTING AND NOT COUNTING THE |
| | TANDEM SPACES IN THE TOTAL. IT MAY BE BEST TO HAVE A |
| | TOTAL OF THE SPACES THAT COUNT TOWARD THE PARKING |
| | REQUIREMENT AND THEN LIST THE TANDEM SPACES ON EACH |
| | FLOOR BELOW THE TOTAL AS ADDITIONAL AVAILABLE PARKING. |
| | |
| | 31) THANK YOU FOR PROVIDING BICYCLE PARKING; HOWEVER: |
| | |
| | A. PROVIDE THE DIMENSIONS FOR THE BICYCLE RACK PAD |
| | ALONG SOUTH OLIVE. THE DEPTH MUST BE AT LEAST SIX FEET |
| | AND THE WIDTH IS BASED ON THE NUMBER OF RACK ELEMENTS. |
| | B. PROVIDE THE DETAILS OF THE BICYCLE RACKS THAT WILL |
| | BE USED WITHIN THE BICYCLE STORAGE ROOMS. THE BICYCLE |
| | STORAGE ROOMS MUST SHOW THE ACCURATE RACKS AND THE |
| | DIMENSIONS REQUIRED BASED ON THE TYPE OF RACKS. |
| | C. REPEAT COMMENT: YOU MUST HAVE BICYCLE PARKING FOR |
| | GUESTS (VISITORS) NEAR ONE OF THE GUEST ACCESSIBLE |
| | ENTRANCES TO THE BUILDING. THE BICYCLE RACK BY THE CAFE |
| | IS NOT NEAR AN ENTRANCE TO THE RESIDENTIAL PORTION OF |
| | THE BUILDING THAT A GUEST CAN USE. IDENTIFY THE |
| | ENTRANCE(S) THAT ARE GUEST ACCESSIBLE AND PROVIDE AT |
| | LEAST ONE BICYCLE RACK, WITH PAD DIMENSIONS, ADJACENT |
| | TO THAT ENTRANCE. |
| | |
| | 32) UPDATED COMMENT: PROVIDE MORE DETAIL ON THE |
| | PROPOSED PRE-WIRING OF THE BUILDING FOR EV CHARGER |
| | INSTALLATION. WHILE STAFF APPRECIATES THAT YOU HAVE |
| | SHOWN 4 EV SPACES, NO DETAILS ON HOW THESE ACTUALLY |
| | FUNCTION WERE PROVIDED, TO INCLUDE WHERE THE CHARGING |
| | UNITS WOULD BE PLACED. PLEASE BE AWARE THAT AT LEAST |
| | ONE ADA PARKING SPACE WILL NEED TO BE EV COMPATIBLE. |
| | BELOW ARE THE REQUIREMENTS FOR EV FACILITIES BASED ON |
| | THE FORTE PROJECT REQUIREMENTS AND ARE THE EXPECTATIONS |
| | FOR THIS PROJECT. PLEASE NOTE THAT IT MAKES AVAILABLE |
| | LEVEL I CHARGING FOR EVERY UNIT OWNER WITH THE |
| | FACILITIES IN PLACE TO UPGRADE TO A LEVEL 2 CHARGER. |
| | |
| | CHARGING STATIONS: ELECTRONIC VEHICLE INFRASTRUCTURE |
| | MUST BE INSTALLED IN ACCORDANCE WITH PERMITS ISSUED BY |
| | THE CITY?S BUILDING DIVISION AS FOLLOWS: |
| | |
| | A. ONE LEVEL 1 FULL CIRCUIT INSTALLATION IS REQUIRED |
| | FOR EACH UNIT'S REQUIRED PARKING SPACES (109 TOTAL). |
| | EACH CIRCUIT IS REQUIRED TO BE A 20 AMP, 120 VOLT |
| | CIRCUIT, WITH RACEWAY/CONDUIT, WIRING, RECEPTACLE AND |
| | OVERCURRENT PROTECTION TO CODE. THE DEVELOPER SHALL |
| | INSTALL OVERSIZED RACEWAY/CONDUIT OR ADDITIONAL |
| | RACEWAY/CONDUIT, AS APPROVED BY THE CITY'S BUILDING |
| | DIVISION, THAT WILL PROVIDE THE ABILITY OF INDIVIDUAL |
| | UNIT OWNERS OR THE HOMEOWNERS? ASSOCIATION TO INSTALL |
| | THE WIRING, RECEPTACLE AND OVERCURRENT PROTECTION TO |
| | CODE TO ALLOW PARKING SPACES TO BE UPGRADED TO A LEVEL |
| | 2, 40 AMP, 208/240 VOLT CIRCUIT. THE DEVELOPER SHALL |
| | PROVIDE SPACE TO INSTALL AN ADDITIONAL ELECTRICAL PANEL |
| | TO ACCOMMODATE LEVEL 2 FULL CIRCUIT UPGRADES. |
| | |
| | B. TWO LEVEL 2 FULL CIRCUIT INSTALLATIONS ARE REQUIRED |
| | FOR THE GUEST PARKING SPACES. EACH CIRCUIT IS REQUIRED |
| | TO BE A 40 AMP, 208/240 VOLT CIRCUIT, WITH |
| | RACEWAY/CONDUIT, WIRING, RECEPTACLE AND OVERCURRENT |
| | PROTECTION TO CODE. ONE DUAL PORT ELECTRIC VEHICLE |
| | CHARGER MUST BE INSTALLED FOR THE GUEST PARKING SPACES |
| | PRIOR TO THE ISSUANCE OF THE CERTIFICATE OF OCCUPANCY |
| | FOR THE BUILDING. |
| | |
| | C. ONE LEVEL 1 FULL CIRCUIT INSTALLATION IS REQUIRED |
| | FOR FOUR (4) OF THE EMPLOYEE PARKING SPACES. EACH |
| | CIRCUIT IS REQUIRED TO BE A 20 AMP, 120 VOLT CIRCUIT, |
| | WITH RACEWAY/CONDUIT, WIRING, RECEPTACLE AND |
| | OVERCURRENT PROTECTION TO CODE. |
| | |
| | D. FOUR LEVEL 2 FULL CIRCUIT INSTALLATIONS ARE REQUIRED |
| | FOR THE VALET PARKING SPACES. EACH CIRCUIT IS REQUIRED |
| | TO BE A 40 AMP, 208/240 VOLT CIRCUIT, WITH |
| | RACEWAY/CONDUIT, WIRING, RECEPTACLE AND OVERCURRENT |
| | PROTECTION TO CODE. TWO DUAL PORT ELECTRIC VEHICLE |
| | CHARGERS MUST BE INSTALLED FOR THE VALET PARKING SPACES |
| | PRIOR TO THE ISSUANCE OF THE CERTIFICATE OF OCCUPANCY |
| | FOR THE BUILDING. THE VALET SPACES CONTAINING THE |
| | ELECTRIC VEHICLE CHARGERS MAY NOT BE SOLD OR LEASED TO |
| | RESIDENTS AND MUST REMAIN AVAILABLE FOR CHARGING |
| | VEHICLES. |
| | |
| | LOADING/ACCESS |
| | |
| | 33) UPDATED COMMENT: THE NORTH SIDE OF CURRIE CRESCENT |
| | HAS ON-STREET PARALLEL PARKING SPACES. THE TRUCK |
| | TURNING DIAGRAM SHOWS THE TRUCK USING THE FULL WIDTH OF |
| | CURRIE CRESCENT, WHICH IS IMPOSSIBLE IF A CAR IS PARKED |
| | IN THE PARALLEL SPACES. THE CITY'S PARKING DEPARTMENT |
| | DOES NOT SUPPORT THE REMOVAL OF PARKING SPACES IN THIS |
| | AREA AS THE PARKING SPACES SEE SIGNIFICANT USAGE. THE |
| | PARKING DIVISION WILL SUPPORT THE RELOCATION OF THE |
| | FIVE EXISTING PARKING SPACES TO THE NORTH SIDE OF DIANA |
| | PLACE. YOU NEED TO SHOW THE RELOCATED PARKING SPACES |
| | ALONG DIANA PLACE. SUGGESTION: RECONFIGURE THE PARKING |
| | ALONG THE NORTH SIDE OF DIANA PLACE TO BE A PARALLEL |
| | CONFIGURATION. THIS WOULD ALLOW MORE ROOM FOR TREES AT |
| | THE WEST END OF ROAD (WHERE THE ANGLE PARKING CURRENTLY |
| | EXISTS), PUSH CARS (AND THEIR HEADLIGHTS AT NIGHT) |
| | FURTHER AWAY FROM THE TOWNHOUSE UNITS ON THE WEST END |
| | OF THE DEVELOPMENT, AND WOULD PROVIDE PARKING SPACES IN |
| | FRONT OF ALL OF THE TOWNHOUSE UNITS THAT COULD BE |
| | UTILIZED BY UNIT OWNER GUESTS WHO DO NOT WANT TO PARK |
| | IN THE GARAGE. |
| | |
| | 34) REPEAT COMMENT: THE CITY'S ENGINEERING SERVICES |
| | DEPARTMENT NEEDS TO APPROVE THE USE OF CURRIE CRESCENT |
| | FOR MANEUVERING PRIOR TO THE CASE PROCEEDING THROUGH |
| | THE PUBLIC HEARING PROCESS. CALL TO DISCUSS IS |
| | SCHEDULED. |
| | |
| | 35) REPEAT COMMENT: THE CITY'S ENGINEERING SERVICES |
| | DEPARTMENT NEEDS TO APPROVE THE NUMBER OF ACCESS POINTS |
| | TO CURRIE CRESCENT AND THE SEPARATION OF ACCESS POINTS |
| | TO THE CASE PROCEEDING THROUGH THE PUBLIC HEARING |
| | PROCESS. CALL TO DISCUSS IS SCHEDULED. |
| | |
| | WALLS |
| | |
| | 36) PROVIDE THE DETAILS OF THE DECORATIVE THREE-FOOT |
| | WALL ALONG THE VEHICULAR USE AREA ON THE NORTH PROPERTY |
| | LINE AND THE RETAINING WALLS. |
| | |
| | 37) THE PLANS SHOW A FENCE ALONG DIANA PLACE AT THE |
| | TOWNHOUSE COURTYARDS. PLEASE PROVIDE DETAILS OF THE |
| | TYPE OF FENCE AND THE COLUMNS AND GATES. SHEET LG-1.1 |
| | CALLS OUT THE COLUMNS AND GATES AS MAXIMUM 6 FEET. THE |
| | PLANS DO NOT CALL OUT WHAT HEDGE MATERIAL WILL SCREEN |
| | THE 4-FOOT-TALL FENCE. IN ORDER TO PROVIDE A |
| | COMFORTABLE PEDESTRIAN EXPERIENCE ALONG THE NEW DIANA |
| | PLACE WALKWAY, THE GATES NEED TO BE A PICKET STYLE AND |
| | THE HEDGE AND GATES SHALL NOT EXCEED 5 FEET IN HEIGHT. |
| | |
| | 38) PROVIDE THE DETAILS OF THE STONE PLINTH WITH |
| | DECORATIVE FENCE LISTED ON THE HARDSCAPE PLAN. |
| | |
| | SIGNAGE |
| | |
| | 39) ONE OF THE COMMENT RESPONSES STATED THAT THERE |
| | WOULD BE DIRECTIONAL SIGNAGE TO GUIDE DRIVING CUSTOMERS |
| | TO THE CAFE PARKING. PLEASE REVIEW THE SIGNAGE |
| | ALLOWANCE FOR PARKING AREA IDENTIFICATION SIGNS TO |
| | VERIFY WHAT SIZE AND SETBACKS ARE PERMITTED. PLEASE |
| | NOTE THAT A BUSINESS NAME/LOGO IS NOT PERMITTED ON |
| | PARKING AREA DIRECTIONAL SIGNS BY RIGHT. IF A SIGN THAT |
| | DOES NOT CONFORM THE BY RIGHT ALLOWANCE IS BEING |
| | CONTEMPLATED, THEN A SIGN PROGRAM THAT WAIVES THE CODE |
| | PROVISIONS MUST BE APPROVED BY THE CITY COMMISSION |
| | EITHER AS PART OF THIS APPLICATION OR A SEPARATE FUTURE |
| | MAJOR PLANNED DEVELOPMENT AMENDMENT. IF IT WILL BE |
| | REVIEWED NOW, THE DETAILS MUST BE SUBMITTED FOR STAFF |
| | REVIEW. |
| | |
| | 40) WHILE REVIEWING THE RESPONSE THAT GENERATED THE |
| | PREVIOUS COMMENT, STAFF NOTED THAT NO SIGNAGE HAS BEEN |
| | PROPOSED FOR THE PROPERTY. IT IS NOT REQUIRED THAT YOU |
| | PROVIDE SIGN PLANS WITH THE APPLICATION; HOWEVER, THE |
| | FUTURE SIGN PLANS MUST THEN COMPLY WITH ALL CODE |
| | PROVISIONS. ANY WAIVERS OR DEVIATIONS FROM THE CODE |
| | PROVISIONS WOULD NEED TO BE APPROVED BY THE CITY |
| | COMMISSION AS A FUTURE MAJOR PLANNED DEVELOPMENT |
| | AMENDMENT. ADDITIONALLY, EVEN CODE COMPLIANT |
| | FREE-STANDING SIGNS ARE CHANGES TO THE SITE PLAN, SO |
| | THEIR LOCATION WILL REQUIRE A FUTURE MINOR PLANNED |
| | DEVELOPMENT AMENDMENT. |
| | |
| | LANDSCAPE |
| | |
| | 41) THE LANDSCAPE PLANS NEED TO BE CLEANED UP TO SHOW |
| | THE FINAL CONDITIONS ONLY. THE CURRENT PLANS INCLUDE |
| | TREES THAT WILL NO LONGER REMAIN WHEN THE PROJECT IS |
| | COMPLETED AND STRAY LINEWORK FROM THE EXISTING SITE |
| | FEATURES (EX. CURBING IN THE NORTHEAST CORNER OF THE |
| | PLAN WHICH MAKES IT APPEAR THAT THERE IS A WALL ACROSS |
| | THE ENTRY DRIVE FROM FLAGLER). |
| | |
| | 42) SHEET LG-3.1 SHOWS THE STORMWATER LINE ALONG THE |
| | LENGTH OF THE WEST SIDE OF THE BUILDING WHILE SHEET |
| | C-500 DOES NOT SHOW THE STORMWATER LINE IN THE SAME |
| | CONFIGURATION. ALL PLANS MUST SHOW THE SAME, ACCURATE |
| | CONDITIONS. |
| | |
| | 43) THE CIVIL AND LANDSCAPE PLANS SHOW AN FPL LINE |
| | ALONG THE FLAGLER DRIVE FRONTAGE. PROVIDE A CROSS |
| | SECTION SHOWING THE DUCT BANK AND ITS RELATIONSHIP TO |
| | THE ROOT ZONES FOR THE OAK TREES PROPOSED ALONG FLAGLER |
| | DRIVE. |
| | |
| | 44) SHEET LG-3.1 SHOWS PLANTING BEDS AGAINST THE WEST |
| | SIDE OF THE BUILDING WHICH ARE NOT REFLECTED ON THE |
| | CIVIL SHEETS OR SITE PLAN. ALL PLANS MUST SHOW THE |
| | SAME, ACCURATE CONDITIONS. |
| | |
| | DEVELOPMENT REGULATION: FPL EASEMENT WHICH BISECTS THE |
| | PROPOSED BUILDING LOCATION WILL NEED TO BE RELEASED BY |
| | FPL AND ALL OVERHEAD LINES MUST BE REMOVED. ANY NEW |
| | UTILITY LINES MUST BE RELOCATED UNDERGROUND. |
| | |
| | DEVELOPMENT REGULATION: THE IMPROVEMENTS TO THE CITY |
| | OWNED PARCEL SOUTH OF THE PROPERTY, INCLUDING THE |
| | SIDEWALK, WALKWAYS AND LANDSCAPE, WILL BE THE |
| | MAINTENANCE RESPONSIBILITY OF THE FLAGLER TOWERS |
| | PROJECT. MAINTENANCE AGREEMENTS AND EASEMENTS WILL BE |
| | REQUIRED. |
| | |
| | |
| | |
| |
Print |