2022-06-01 10:48:26FROM: RAY CARANCI, SENIOR LANDSCAPE PLANNER
 561-822-1462
 PROJECT: 8TH ST AND RAILROAD AVE PARKING LOTS Z21040012
 MAY 31, 2022
 I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND
 PROVIDE THE FOLLOWING COMMENTS:
  
  
 1. SATISFIED. ADD TREES #19 MANGO AND #15 QUEEN PALM TO
 THE TREE DISPOSITION LIST AND CALCULATE THE MITIGATION
 DUE. MAHOGANY TREES #17 AND #18 ARE NOT IN GOOD
 CONDITION DUE TO PRUNING FOR FPL LINE CLEARANCE AND
 CONFLICT WITH THE PROPOSED EXFILTRATION SO DO NOT HAVE
 TO BE PRESERVED. SHOW ON DISPOSITION LIST AS REMOVE AND
 CALCULATE THE MITIGATION DUE. TREES LESS THAN 20 FEET
 IN CANOPY DIAMETER AND PALMS ARE CALCULATED BY
 CATEGORY, AND ANY TREES 20 FEET IN CANOPY DIAMETER OR
 GREATER USE THE ACTUAL SQUARE FOOTAGE. PROVIDE THE
 TOTAL MITIGATION DUE.
  
 2. SATISFIED. PROVIDE CANOPY CREDIT CALCULATIONS FOR
 TREES PROPOSED ON THE LANDSCAPE PLANT LIST TO SHOW
 CANOPY MITIGATION DUE IS PROVIDED.
  
 3. SATISFIED. LANDSCAPE TERMINAL ISLANDS AND INTERIOR
 ISLANDS ARE REQUIRED TO MEASURE AT LEAST 8 FEET IN
 WIDTH FOR THE LANDSCAPE AREA PER SECTION 94-443(C)A.
 AND B. REQUIRED BUFFER OF 5 FEET MAY BE COUNTED AS PART
 OF THE WIDTH AND THEN THE ADDITIONAL 3 FEET INCLUDED.
 THERE ARE 7 TERMINAL ISLANDS AND 4 INTERIOR ISLANDS
 THAT DO NOT MEET THE REQUIREMENT.
  
 4. SATISFIED. PER SECTION 94-443(C)(2), PROVIDE THE
 CALCULATIONS FOR THE REQUIRED NUMBER OF BUFFER TREES AT
 30 FOOT INTERVALS AND THE REQUIRED HEDGE FOR EACH
 BUFFER SEGMENT ON EACH PARCEL AND SHOW THE NUMBER OF
 PROVIDED TREES FOR EACH BUFFER SECTION. DRIVEWAYS ARE
 NOT DEDUCTED FOR EACH PROPERTY LINE SEGMENT
 MEASUREMENT. REQUIRED TERMINAL ISLAND TREES MAY NOT BE
 COUNTED TOWARD BUFFER REQUIRED TREES.
 CALCULATIONS MUST BE PROVIDED IN A CHART.
  
  
 5. SATISFIED. SECTION 94-443(C)(3) REQUIRES THAT A
 MINIMUM OF 75 PERCENT OF ALL TREES THAT ARE REQUIRED TO
 BE PLANTED WITHIN THE INTERIOR OF AN OFF STREET PARKING
 AREA SHALL BE CATEGORY 1 SHADE TREES. PROVIDE THE
 CALCULATIONS FOR EACH PARCEL. BLOCK 8 AND 9A APPEAR TO
 FALL SHORT OF THE 75%.
 CALCULATIONS MUST BE PROVIDED IN A CHART.
  
 6. SATISFIED. PROVIDE AN EXHIBIT SHOWING THE PARKING
 AREA SURFACE CALCULATIONS, PARKING SPACE AREAS AND
 LANDSCAPE AREAS PROVIDED TO DEMONSTRATE COMPLIANCE WITH
 SECTIONS 94-443 (C)(3) AND (4) FOR EACH PARCEL.
  
 AREAS NEED TO MATCH THE CLASSIFICATIONS AS SHOWN IN
 FIGURE XIV-1 FOR THE PROVIDED INTERIOR LANDSCAPE AREA.
 BUFFERS ARE NOT COUNTED TOWARD COMPLIANCE.
  
 7. SATISFIED. STREETSCAPE PLANTINGS FOR RAILROAD AVENUE
 ARE INCLUDED WITH THESE PLANS BUT WILL BE PART OF A
 SEPARATE APPLICATION AND APPROVAL. CLARIFY WITH A NOTE
 ON THE PLANS. PLANT LISTS SHOULD BE SEPARATED FOR THE
 STREETSCAPE AND THE ONSITE LANDSCAPING.
  
 8. SATISFIED. TREES MUST MEET THE MINIMUM SIZE OF 12
 FEET IN HEIGHT AND MEET FLORIDA GRADE #1 STANDARDS.
 CORRECT SIZES ON PLANT LIST.
  
 PIMENTA RACEMOSE IS STILL LISTED AT 10 FEET AND DOES
 NOT MEET THE MINIMUM REQUIREMENT.
  
 9. CONDITIONALLY SATISFIED. SHOW LIGHTING LOCATIONS ON
 THE TREE PLAN TO AVOID CONFLICTS WITH TREES.
  
 10. SATISFIED. THERE APPEARS TO BE A STREET LIGHT POLE
 IN THE PROPOSED DRIVEWAY ONTO 9TH ST. THAT WILL NEED TO
 BE RELOCATED.
 11. SATISFIED. CONSIDER HAVING THE ADA CONNECTION FOR
 BLOCK 8 CONNECT TO RAILROAD AVENUE RATHER THAN 8TH ST.
  
 ADDITIONAL COMMENTS 9/7/21:
  
 12. SATISFIED. CORRECT THE PHOTO TO SHOW A GREEN
 BUTTONWOOD TREE AS LABELED. THE PHOTO IS OF A SILVER
 BUTTONWOOD. SHEET
  
 13. CONDITIONALLY SATISFIED. IN FLORIDA FRIENDLY POINTS
 CHART, 51% OR MORE CAN ONLY BE COUNTED ONCE IN EACH
 DESIGN OPTION. 4. SHRUBS AND 5. TREES HAVE 2 CATEGORIES
 THAT ADD UP TO MORE THAN 100%. SHEET L0-003.
  
 14. SATISFIED. REMOVE REFERENCE TO OPEN SPACE FROM
 LANDSCAPE AREA LINE AND RELABEL CHART AS ?OPEN SPACE
 AREAS?. SHEET L0-003
  
  
 CONDITIONS OF APPROVAL
 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON
 THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE
 SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT
 SERVICES DEPARTMENT, PLANNING DIVISION.
  
 2. SATISFIED. PRIOR TO ISSUANCE OF THE SITE PLAN
 APPROVAL, THE PLANS SHALL BE REVISED TO CORRECT THE
 FLORIDA FRIENDLY POINTS CHART, AS 51% OR MORE CAN ONLY
 BE COUNTED ONCE IN EACH DESIGN OPTION. 3. GROUNDCOVERS,
 4. SHRUBS AND 5. TREES HAVE 2 CATEGORIES THAT ADD UP TO
 MORE THAN 100%. SHEET L0-003. PROVIDE THE LOCATIONS OF
 THE EXTRA TREES FOR 6. B. OR REMOVE POINTS.
  
  
 3. AT THE TIME OF PERMITTING FOR INSTALLATION OF THE
 PARKING LOTS, THE REQUIRED STREET TREES ON 8TH AND 9TH
 STREETS ADJACENT TO THE PROPERTY LINES OF THE LOTS
 SHALL BE INSTALLED PER SECTION 94-113. LIVE OAKS SHALL
 BE PREFERRED.
  
 4. SATISFIED. PRIOR TO ISSUANCE OF THE SITE PLAN
 APPROVAL, THE PLANS SHALL BE REVISED TO RELOCATE THE
 ADA ACCESS OUT OF THE TERMINAL LANDSCAPE ISLANDS FOR
 BLOCK 8A AND 9A.
  
 5. SATISFIED. PRIOR TO ISSUANCE OF THE SITE PLAN
 APPROVAL, THE LANDSCAPE PLANS SHALL BE REVISED TO SHOW
 THE LOCATIONS OF LIGHTING TO AVOID CONFLICTS WITH
 TREES.
  
  
 6. ALL GROUND MOUNTED EQUIPMENT INCLUDING FPL
 TRANSFORMERS SHALL BE SCREENED WITH HEDGES.
  
  Print