| Plan Review Notes For Project Z21040012 |
| Project Number |
Z21040012 |
|
| Review Stop |
TRAFFIC |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2021-05-07 11:41:47 | SITE COMMENTS | | | 1) PROVIDE AUTOTURN ANALYSIS USING AN HANDICAP VAN AS | | | DESIGN VEHICLE | | | 2) PROVIDE PARKING STALL ANGLE AND REFER TO FIGURE XV-2 | | | OF CITY CODE SEC. 94-485 FOR THE CORRESPONDING MINIMUM | | | DRIVING AISLE WIDTH | | | 3) IDENTIFY AND DESIGNATE AN EASILY ACCESSIBLE | | | MICRO-MOBILITY STATION AREA (MINIMUM 8 X 20 FEET) AND | | | PROVIDE BASIC ELECTRIFICATION READINESS (CIRCUIT BOX | | | AND ELECTRIC CONDUIT) | | | 4) PROVIDE THE REQUIRED NUMBER OF BICYCLE PARKING | | | SPACES. | | | 5) PROVIDE A TABLE SUMMARIZING THE NUMBER OF PARKING | | | SPACES PROVIDED, INCLUSIVE OF ADA AND BICYCLE ONES | | | 6) PROVIDE A MINIMUM 5-FOOT SIDEWALK ALONG 8TH AND 9TH | | | ST | | | 7) PROVIDE A MINIMUM 10-FOOT SIDEWALK ALONG RAILROAD | | | AVENUE | | | 8) REPAVE THE ALLEYS ALONG SITE FRONTAGE | | | | | | VALERIO ORICCHIO | | | CITY TRANSPORTATION ENGINEER | | | 561-494-1092 | | | [email protected] | | | |
| |