| 2022-02-07 09:56:39 | INFORMAL SITE PLAN REVIEW 21-05 - DECEMBER 14, 2021 |
| | RESUBMITTAL |
| | PUBLIX @ SOUTHDALE |
| | 804 SOUTHERN BOULEVARD |
| | |
| | - CONTACT ERIC SCHNEIDER @ (561) 822-1446, |
| | [email protected] |
| | |
| | - PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN |
| | WRITTEN FORMAT. |
| | |
| | - WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF THREE |
| | (3) PAPER COPIES AND AN ELECTRONIC COPY IN .PDF FORMAT |
| | OF ALL PLANS. PLEASE NOTE THAT CHANGES ON THE |
| | RESUBMITTED PLANS OR THE SUBMITTAL OF INFORMATION/PLANS |
| | TO ADDRESS THE COMMENTS MAY RESULT IN ADDITIONAL |
| | COMMENTS. |
| | |
| | - PLEASE NOTE THAT IF THE PLANNING DIVISION HAS NOT |
| | RECEIVED A RESPONSE TO THE PPRC COMMENTS WITHIN 60 DAYS |
| | FROM THE DATE OF THESE COMMENTS (BY APRIL 7, 2021), THE |
| | PLANNING DIVISION MAY NOTIFY THE APPLICANT THAT THE |
| | CASE IS CONSIDERED WITHDRAWN. ANY FURTHER ACTION SHALL |
| | REQUIRE A NEW DEVELOPMENT APPLICATION. |
| | |
| | - PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1) |
| | ADDITIONAL RESUBMITTAL AT NO ADDITIONAL COST. IF |
| | PREVIOUSLY ISSUED COMMENTS CONTINUE TO NOT BE |
| | SUFFICIENTLY ADDRESSED, THE APPLICANT WILL BE ASSESSED |
| | A RESUBMITTAL FEE. SUCH FEE WILL BE 20% OF THE ORIGINAL |
| | APPLICATION FEE ($200). |
| | |
| | 1) UPDATED COMMENT: PROVIDE THE COMCAST, AND WEST PALM |
| | BEACH UTILITY LETTER APPROVALS. |
| | |
| | 2) UPDATED COMMENT: PARKING DETAILS ARE REQUIRED FOR |
| | ALL CONDITIONS. NO PARKING DETAILS WERE PROVIDED. |
| | PLEASE NOTE THAT THE WHEEL STOPS SHOWN ADJACENT TO THE |
| | BUILDING DO NOT MEET THE CODE REQUIRED TWO FEET FROM |
| | THE END OF THE PARKING SPACE. |
| | |
| | 3) REPEAT COMMENT: THE ZONING AND LAND DEVELOPMENT |
| | REQUIREMENTS REQUIRE THAT PARKING LOT LANDSCAPE ISLANDS |
| | BE THE FULL LENGTH OF THE PARKING SPACE. THE PLANS DO |
| | NOT COMPLY WITH THIS REQUIREMENT. YOU MUST EITHER |
| | LENGTHEN THE LANDSCAPE ISLANDS OR STRIPE THE SPACES TO |
| | NOT EXCEED THE ISLAND LENGTH. NOTE: THE ISLANDS SCALE |
| | TO THE MEET THE MINIMUM PARKING STALL LENGTH, SO THE |
| | ISLANDS CAN STAY THE LENGTH AS SHOWN IF THE STALL |
| | LENGTH IS REDUCED. |
| | |
| | 4) UPDATED COMMENT: NOT ALL THE SCREEN WALL LOCATIONS |
| | ARE SHOWN ON THE CIVIL AND LANDSCAPE PLANS. THE CITY |
| | DOES NOT PERMIT CHAIN LINK FENCES TO SCREEN GENERATORS, |
| | WHICH IS WHAT IS CALLED OUT ON THE ELEVATION PLAN. |
| | |
| | 5) THE BICYCLE RACK AT THE BANK NEEDS TO HAVE 24 INCHES |
| | ON EACH SIDE OF THE RACK, NOT 24 INCHES OF WIDTH. |
| | |
| | 6) UPDATED COMMENT: THANK YOU FOR PROVIDING THE |
| | COMPACTOR SCREENING DETAILS ON THE ELEVATION PLANS; |
| | HOWEVER, THE ENCLOSURE IS NOT SHOWN ON THE SITE PLAN AS |
| | REQUIRED. |
| | |
| | 7) UPDATED COMMENT: THANK YOU FOR PROVIDING THE |
| | LOCATION OF THE LIGHTING IN THE PARKING LOT. THERE ARE |
| | SEVERAL POLES LOCATED WITHIN THE PARKING FIELD BETWEEN |
| | PARKING SPACES. PROVIDE DETAILS THAT INCLUDE THE |
| | DIMENSION OF THE POLE AND ANY BOLLARDS OR OTHER |
| | PROTECTIVE DEVICES OVERLAID ON A TO SCALE PARKING STALL |
| | LAYOUT SO THAT STAFF CAN VERIFY THAT THE PROPOSED |
| | LAYOUT STILL PERMITS THE PARKING SPACES TO MEET CODE |
| | REQUIREMENTS. |
| | |
| | 8) IN AN EMAIL TO LENS LUBIN, DATED SEPTEMBER 9, 2021, |
| | IN WHICH STAFF MADE AN IN-PROGRESS REVIEW OF THE PLANS, |
| | STAFF PROVIDED THE ADDITIONAL COMMENT BELOW, WHICH WAS |
| | NOT ADDRESSED AS PART OF THIS RESUBMITTAL: |
| | |
| | THE COLOR ELEVATIONS DO NOT SHOW THE PROPOSED RAMP |
| | ALONG THE WEST SIDE OF THE BUILDING. THE HEIGHT OF THE |
| | TOP OF THE RAIL MUST BE PROVIDED. PLEASE NOTE THAT THIS |
| | RAMP ENCROACHES INTO THE REQUIRED SETBACK AND LANDSCAPE |
| | BUFFER AND UNLESS IT IS SPECIFICALLY THERE TO MEET ADA |
| | REQUIREMENTS IT IS NOT PERMITTED. IF IT IS FOR ADA |
| | PURPOSES AND THE PURPOSED CANNOT BE ACHIEVED BY ANOTHER |
| | METHOD, YOU MUST SUBMIT A LETTER WITH YOUR RESUBMITTAL |
| | REQUESTING A REASONABLE ACCOMMODATION DETERMINATION |
| | BASED ON THE RAMP BEING INSTALLED TO MEET ADA |
| | PROVISIONS (PLEASE INCLUDE THE ADA CODE CITATION MET) |
| | AND THEN THE CITY WILL GRANT THE REASONABLE |
| | ACCOMMODATION TO WAIVE THE REQUIREMENT TO COMPLY WITH |
| | THE SETBACK AND LANDSCAPE BUFFER ENCROACHMENT. NOTE: |
| | THE TOP OF THE RAIL FROM GRADE MAY NOT EXCEED 6 FEET OR |
| | IT ALSO FALLS UNDER THE REASONABLE ACCOMMODATION |
| | WAIVER. |
| | |
| | 9) CONDITION (DRAFT): THE MICRO-MOBILITY STATION AREA |
| | MUST BE PROVIDED WITH BASIC ELECTRIFICATION READINESS |
| | CONSISTING OF AN ELECTRICAL PULL BOX (240V CIRCUIT) AND |
| | 2-INCH SCHEDULE 40 PVC ELECTRIC CONDUIT TO THE POWER |
| | SOURCE. THE ELECTRICAL READINESS MUST BE APPROVED BY |
| | THE CITY'S TRAFFIC ENGINEER AND INSTALLED PRIOR TO THE |
| | CERTIFICATE OF OCCUPANCY FOR THE NEW PUBLIX. |
| | |
| | |
| |