| Date |
Text |
| 2021-04-26 10:23:11 | CASE NO. PB 1060NN |
| | FLAMINGO CAR WASH II |
| | 879 WEST EXECUTIVE CENTER DRIVE |
| | |
| | - CONTACT ERIC SCHNEIDER @ (561) 822-1446 |
| | |
| | - PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN |
| | WRITTEN FORMAT. |
| | |
| | - WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF FOUR |
| | (4) PAPER COPIES AND AN ELECTRONIC COPY IN .PNG FORMAT |
| | OF ALL PLANS. PLEASE NOTE THAT CHANGES ON THE |
| | RESUBMITTED PLANS OR THE SUBMITTAL OF INFORMATION/PLANS |
| | TO ADDRESS THE COMMENTS MAY RESULT IN ADDITIONAL |
| | COMMENTS. |
| | |
| | - UPON STAFF REVIEW OF THE RESUBMITTED PLANS AND |
| | DETERMINATION THAT THE NEW PLANS HAVE MET THE COMMENTS, |
| | YOU WILL BE SCHEDULED FOR THE NEXT AVAILABLE PLANNING |
| | BOARD MEETING. |
| | |
| | - PLEASE NOTE THAT IF THE PLANNING DIVISION HAS NOT |
| | RECEIVED A RESPONSE TO THE PPRC COMMENTS WITHIN 60 DAYS |
| | FROM THE DATE OF THE PPRC MEETING (BY MAY 11, 2021), |
| | THE CASE SHALL BE CONSIDERED WITHDRAWN. ANY FURTHER |
| | ACTION SHALL REQUIRE A NEW DEVELOPMENT APPLICATION. |
| | |
| | - PLEASE NOTE THAT YOU WILL BE PERMITTED ONE ADDITIONAL |
| | RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY-ISSUED |
| | COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE |
| | APPLICANT WILL BE ASSESSED A RESUBMITTAL FEE. SUCH FEE |
| | WILL BE 20% OF THE ORIGINAL APPLICATION FEE ($600). |
| | |
| | - PUBLIC HEARING NOTIFICATION SIGNAGE SHALL BE POSTED |
| | IN ACCORDANCE WITH THE REQUIREMENTS OF SECTION |
| | 94-39(I)(5) OF THE ZONING AND LAND DEVELOPMENT |
| | REGULATIONS. |
| | |
| | 1) REPEAT COMMENT: YOU NEED TO SHOW THE CORRECT TRAFFIC |
| | MARKINGS ON THE SITE PLAN (EXAMPLE STOP BAR AND SIGN |
| | FOR VEHICLES EXITING THE BRANDSMART/BJS SITE), EVEN |
| | THOUGH THEY WILL NOT NEED TO BE INSTALLED UNTIL THE |
| | CONNECTION IS COMPLETED. |
| | |
| | 2) REPEAT COMMENT: PROVIDE A COPY OF THE FPU, FPL AND |
| | COMCAST LETTERS OF NO OBJECTION. |
| | |
| | 3) THANK YOU FOR PROVIDING THE PAY STRUCTURE |
| | ELEVATIONS. THE SOUTHERN WALL CONTINUES TO BE SHOWN |
| | ENCROACHING INTO THE REQUIRED FIVE (5) FOOT SIDE |
| | SETBACK, WHICH IS NOT PERMITTED. PROVIDE THE DIMENSION |
| | OF THE ARCHITECTURAL OVERHANG FROM THE BUILDING WALL. |
| | THE OVERHANG MAY NOT ENCROACH MORE THEN THREE (3) FEET |
| | INTO THE REQUIRED SETBACK. |
| | |
| | 4) THE LANDSCAPE AND SITE PLANS NEED TO SHOW THE |
| | REVISED LOCATION OF THE CONTROL STRUCTURE AND OUTFALL |
| | PIPE AND THE CONNECTION TO THE STORM MANHOLE ON THE |
| | BRANDSMART PROPERTY. NOTE: THE LANDSCAPE PLAN NEEDS TO |
| | SHOW ALL THE UNDERGROUND UTILITY AND DRAINAGE LOCATIONS |
| | (TO INCLUDE THE EXTENT OF THE EASEMENT) SO THAT STAFF |
| | CAN VERIFY THAT THERE ARE NOT CONFLICTS AND THE |
| | PROPOSED ROOT BARRIERS WILL BE EFFECTIVE. IF POSSIBLE, |
| | THE CONTROL STRUCTURE AND OUTFALL PIPES SHOULD BE |
| | LOCATED OUTSIDE OF LANDSCAPE AREAS TO PERMIT TREE ROOT |
| | GROWTH. |
| | |
| | 5) THE CIVIL PLAN CONTINUES TO SHOW THE CITY'S OLD, TOO |
| | SMALL OPENING, DUMPSTER ENCLOSURE. PLEASE REMOVE OR |
| | REPLACE. |
| | |
| | 6) CURRENTLY THE SITE IS ONLY PERMITTED TO HAVE A |
| | RESTAURANT, WHICH IS THE REASON THAT YOU NEED TO AMEND |
| | THE PLANNED DEVELOPMENT TO PERMIT THE CAR WASH USE |
| | (FALLS UNDER THE MOTOR VEHICLE FUEL SALES AND SERVICE |
| | CATEGORY. STAFF IS WONDERING WHY YOU HAVE INCLUDED |
| | MOTOR VEHICLE REPAIR, LIGHT, AS A PERMITTED USE. THIS |
| | ITEM NEEDS FURTHER DISCUSSION. |
| | |
| | 7) PROVIDE THE DIMENSION OF THE ARCHITECTURAL OVERHANG |
| | FROM THE BUILDING WALL OF THE CAR WASH BUILDING. IT |
| | SCALES AT TWO (2) FEET, WHICH WOULD STILL MEET CODE |
| | SINCE THE BUILDING WALL IS SHOWN AT SEVEN (7) AT ITS |
| | CLOSEST POINT TO THE PROPERTY LINE. REMEMBER, THE |
| | OVERHANG MAY NOT ENCROACH MORE THAN THREE (3) FEET INTO |
| | THE REQUIRED SETBACK. |
| | |
| | 8) PROVIDE NOTARIZED VERIFICATION FROM THE NEIGHBORING |
| | PROPERTY OWNER AT 1840 PALM BEACH LAKES BOULEVARD THAT |
| | HE WILL EXTEND THE ACCESS EASEMENT TO THE NEW DRIVEWAY |
| | LOCATION. |
| | |
| | 9) CONDITION (DRAFT): PRIOR TO THE ISSUANCE FOR THE |
| | PERMIT TO CONSTRUCT THE DRIVEWAY CONNECTION TO THE |
| | INTERNAL DRIVE ON THE GAS STATION PARCEL, PROVIDE |
| | VERIFICATION THAT THE ACCESS EASEMENT HAS BEEN MODIFIED |
| | TO REACH YOUR PROPOSED DRIVEWAY. |
| | |
| | 10) CONDITION (DRAFT): PRIOR TO CO OF THE CAR WASH |
| | BUILDING, THE APPLICANT WILL WORK WITH THE CITY TO |
| | TERMINATE AND REDEDICATE THE DRAINAGE EASEMENT IN THE |
| | SOUTHWEST PORTION OF THE SITE TO REFLECT THE ACTUAL |
| | PIPE LOCATION. |
| | |
| |
Print |