| Date |
Text |
| 2021-04-16 17:03:14 | FROM: RAY CARANCI, SENIOR LANDSCAPE PLANNER |
| | 561-822-1462 |
| | PROJECT: FLAMINGO CAR WASH CPD Z21020016 |
| | APRIL 16, 2021 |
| | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND |
| | PROVIDE THE FOLLOWING COMMENTS: |
| | |
| | 1. MAKE THE FOLLOWING CORRECTIONS TO THE TREE |
| | DISPOSITION PLAN: |
| | ? SATISFIED. ADD BRAZILIAN PEPPER TO LIST AND SHOW AS |
| | REMOVE WITH NO MITIGATION REQUIRED. |
| | ? SATISFIED. SHOW SQUARE FOOTAGE OF MITIGATION DUE FOR |
| | EACH TREE TO BE REMOVED ON THE CHART. |
| | ? SATISFIED. CHART SHOWS 2 RELOCATED LIVE OAKS, BUT 3 |
| | ARE SHOWN ON THE PLANT LIST. |
| | |
| | 2. NOT SATISFIED. REQUIRED OPEN SPACE FOR CALCULATING |
| | REQUIRED SHADE TREES AND FLOWERING TREES IS 40%. SHOW |
| | THE CORRECT SQUARE FOOTAGE ON THE REQUIREMENTS CHART |
| | AND RECALCULATE. |
| | |
| | 52925.4 SQ FT LOT, 40% IS 21170 SQ FT. 15 TREES |
| | REQUIRED, 6 FLOWERING TREES AND 43 SHRUBS. CORRECT ON |
| | CHART. BUFFER TREES AND PARKING LOT TREES CAN BE |
| | COUNTED. SHORT ON FLOWERING TREES. |
| | |
| | 3. NOT SATISFIED. SHOW THE PERCENTAGE AND NUMBER OF |
| | PALM SUBSTITUTIONS FOR REQUIRED TREES NOT EXCEEDING 35 |
| | PERCENT PER SECTION 94-442 (D). |
| | COULD NOT LOCATE ON PLAN, ADD TO TREE REQUIREMENT CHART |
| | SO INFORMATION IS CONSOLIDATED. |
| | |
| | 4. NOT SATISFIED. PROVIDE A PLAN SHOWING THE PARKING |
| | LANDSCAPE AREAS COUNTED TOWARD COMPLIANCE WITH SECTION |
| | 94-443(C)(3) AND (4) AND PROVIDE CALCULATIONS. |
| | COULD NOT LOCATE PLAN IN THE SUBMITTAL. |
| | |
| | 5. SATISFIED. BUFFER LENGTHS SHOWN ON CHART ON LP-2 DO |
| | NOT MATCH SURVEY LENGTHS. REVISE AND SHOW NEW |
| | CALCULATIONS. |
| | |
| | 6. SATISFIED. PROVIDE REQUIRED BUFFER TREES AT ONE FOR |
| | EVERY 30 FEET OR PORTION THEREOF FOR EASTERN BUFFER OR |
| | REQUEST A WAIVER. THE DRAINAGE EASEMENT NEEDS TO BE |
| | CLARIFIED IF IT WILL BE USED OR NOT IN COORDINATION |
| | WITH THE ADJACENT PROJECT. PERMISSION MAY BE SOUGHT FOR |
| | INSTALLING THE REQUIRED LANDSCAPE AS AN ALTERNATIVE. |
| | EXTRA TREES IN PARKING AREA WOULD HAVE TO BE PART OF |
| | ANY WAIVER JUSTIFICATION. |
| | |
| | 7. SATISFIED. WESTERN BUFFER WILL NEED TO BE MODIFIED |
| | TO INCORPORATE THE SIDEWALK CONNECTION AS DESCRIBED IN |
| | THE ZONING COMMENTS. |
| | |
| | 8. SATISFIED. NORTHERN 5 FOOT BUFFER SHOULD BE CONSTANT |
| | ACROSS THE ENTIRE LENGTH WITH ACCESS OPENINGS FOR |
| | SIDEWALK ACCESS ONLY. SHADE TREES SHOULD BE CONSISTENT |
| | WITH THE THEME FOR ALL PROPERTIES, THE ROYAL PALMS DO |
| | NOT PROVIDE THE REQUIRED TREE CANOPY. |
| | |
| | 9. NOT SATISFIED. SHOW LINEAR FOOTAGE OF LANDSCAPED |
| | AREA ADJACENT TO THE BUILDING MEETS THE REQUIREMENT OF |
| | 30 PERCENT PER SECTION 94-443(E)(1) FOR THE BUILDING. |
| | |
| | COULD NOT LOCATE ON PLAN. CONSOLIDATE ALL LANDSCAPE |
| | REQUIREMENTS IN ONE CHART. |
| | |
| | 10. SATISFIED. TAGS ARE NOT SHOWN ON LP-1, MAKE SURE |
| | THEY ARE ADDED. |
| | |
| | 11. MAKE THE FOLLOWING CORRECTIONS TO THE PLANT LIST: |
| | ? NOT SATISFIED. QUANTITY FOR SILVER BUTTONWOOD TREES |
| | IS NOT INDICATED, AND SIZE MUST BE 12 FEET. |
| | ? NOT SATISFIED. CRAPE MYRTLE MUST BE 12 FEET. |
| | ? ALL SPECIES LISTED UNDER TREES MUST MEET THE 12 FOOT |
| | HEIGHT REQUIREMENT TO QUALIFY AS TREES, OTHERWISE MOVE |
| | TO SHRUB CATEGORY. |
| | |
| | 12. SATISFIED. SHOW THE LOCATIONS OF DRAINAGE LINES ON |
| | THE LANDSCAPE PLAN AND RESOLVE ANY CONFLICTS WITH TREES |
| | AND LANDSCAPING. RELOCATE UTILITY LOCATIONS OR EXPAND |
| | LANDSCAPE AREAS TO ACCOMMODATE REQUIRED LANDSCAPING. |
| | |
| | 13. SATISFIED. SHOW LOCATIONS OF FPL TRANSFORMERS ON |
| | THE LANDSCAPE PLAN AND RESOLVE CONFLICTS WITH |
| | LANDSCAPING. PROVIDE SCREENING FOR ALL GROUND MOUNTED |
| | VALVES AND EQUIPMENT. |
| | |
| | 14. SATISFIED. ROW OF PARKING SOUTH OF BUILDING SHOULD |
| | BE MODIFIED TO BE 18 FEET LENGTH INCLUDING CURB AND |
| | OVERHANG. |
| | |
| | ADDITIONAL COMMENT 4/16/21: |
| | |
| | 15. REMOVE TREE MITIGATION CREDITS FOR THE RELOCATED |
| | PIGEON PLUM, LIVE OAKS AND SABAL PALMS AND RECALCULATE |
| | TOTAL. MITIGATION CAN ONLY BE PROVIDED WITH NEWLY ADDED |
| | MATERIAL. |
| | CONDITIONS OF APPROVAL |
| | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON |
| | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE |
| | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT |
| | SERVICES DEPARTMENT, PLANNING DIVISION. |
| | |
| |