| 2021-03-29 16:41:27 | TRAFFIC COMMENTS |
| | 1) NOT-SATISFIED. PROVIDE COUNTY TPS LETTER ONCE |
| | AVAILABLE |
| | 2) SATISFIED. SHOWCASE TURNING VOLUMES AT THE FLAMINGO |
| | AND DIXIE INTERSECTION IN FIGURE 2 |
| | 3) SATISFIED. ONLY ONE SCHOOL AND THE TENNIS COURT HAVE |
| | BEEN ACCOUNTED FOR TRIP GENERATION CALCULATIONS. PLEASE |
| | INCLUDE THE OTHER FACILITIES WITHIN THE DEVELOPMENT |
| | (I.E. OFFICE BUILDING AND SECOND SCHOOL) |
| | 4) SATISFIED. PROVIDE INTERSECTION ANALYSIS FOR: |
| | O DIXIE AND BELVEDERE |
| | O DIXIE AND FLAMINGO DR |
| | O DIXIE AND BISCAYNE BLVD |
| | 5) NOT-SATISFIED. PLEASE SUMMARIZE AND TABULARIZE THE |
| | RESULTS OF THE INTERSECTION CAPACITY ANALYSES FOR |
| | FLAMINGO AND BISCAYNE, SPECIFICALLY LOS FOR EACH |
| | SCENARIO. PLEASE INCLUDE PROPER NARRATIVE EXPLAINING |
| | THE RESULTS, HIGHLIGHTING FAILING MOVEMENTS, AND |
| | PROPOSING MITIGATION OR ROADWAY IMPROVEMENTS, IF ANY. |
| | 6) NOT-SATISFIED. CONDUCT A TRAFFIC SIGNAL WARRANT |
| | ANALYSIS FOR THE DIXIE AND BISCAYNE BLVD INTERSECTION |
| | |
| | SITE COMMENTS |
| | 7) PARTIALLY-SATISFIED. PROVIDE DETAILS OF STREETS AND |
| | PARCELS ON THE OPPOSITE OF THE ROAD(S) SURROUNDING THE |
| | PROPOSED DEVELOPMENT (E.G. DRIVEWAYS, CURB CUTS, |
| | PARKING STALLS, ETC.). PLEASE PROVIDE MISSING DETAILS |
| | ALONG CLAREMORE DR. |
| | 8) SATISFIED. PROVIDE A CROSSWALK ACROSS THE BISCAYNE |
| | BLVD DRIVEWAY |
| | 9) SATISFIED. MILL AND REPAVE BISCAYNE BLVD |
| | 10) SATISFIED. PROVIDE AUTOTURN FOR THE LOADING ZONE |
| | 11) SATISFIED. IF NOT PRESENT, PROVIDE BICYCLE RACKS |
| | NEARBY EACH BUILDING OR FACILITY ENTRANCES, AND |
| | IDENTIFY THEM ON THE SITE PLAN. RECORD THE NUMBER OF |
| | BICYCLE PARKING IN THE SITE TABULAR DATA |
| | 12) SATISFIED. ONLY ONE SCHOOL AND THE TENNIS COURTS |
| | WERE INCLUDED IN PARKING CALCULATIONS. PLEASE INCLUDE |
| | THE OTHER FACILITIES WITHIN THE DEVELOPMENT (I.E. |
| | OFFICE BUILDING AND SECOND SCHOOL) |
| | 13) PARTIALLY-SATISFIED. IDENTIFY AND DESIGNATE A |
| | MICRO-MOBILITY STATION AREA (MINIMUM 8 X 20 FEET) AND |
| | PROVIDE BASIC ELECTRIFICATION READINESS (CIRCUIT BOX |
| | AND ELECTRIC CONDUIT). PLEASE LOCATE THE MICROMOBILITY |
| | STATION NEARBY A BUILDING ENTRANCE. |
| | |
| | VALERIO ORICCHIO |
| | CITY TRANSPORTATION ENGINEER |
| | 561-494-1092 |
| | [email protected] |
| | |
| |
Print |