Plan Review Notes
Plan Review Notes For Project Z21010014
Project Number Z21010014
Review Stop L
Sequence Number 1
Notes
Date Text
2021-02-08 16:34:34FROM: RAY CARANCI, SENIOR LANDSCAPE PLANNER
 561-822-1462
 PROJECT: 6910 S DIXIE Z21010014
 FEBRUARY 8, 2021
 I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND
 PROVIDE THE FOLLOWING COMMENTS:
  
 1. CORRECT THE TREE DISPOSITION PLAN TO SHOW 300 SQ FT
 MITIGATION DUE FOR #11 FICUS BENJAMINA, A CATEGORY 1
 TREE, AND 100 SQ FT MITIGATION DUE FOR #25 EUGENIA
 FOETIDA, A CATEGORY 3 TREE. REVISE TOTAL MITIGATION
 DUE.
 2. PROVIDE LOCATIONS FOR TREES WITHIN 10 FEET OF THE
 PROPERTY LINE ON ADJACENT PARCELS AND ADJUST SPACING OF
 PROPOSED TREES TO AVOID CANOPY CONFLICTS PER SECTION
 94-442(B) (2)Q.
  
 3. CORRECT THE REQUIRED OPEN SPACE TO 40% OF THE LOT
 AREA UNDER LANDSCAPE REQUIREMENTS AND RECALCULATE
 REQUIRED TREES, FLOWERING TREES AND SHRUBS. WILL BE
 16,096 SQ FT.AS SHOWN ON DATA CHART.
 4. PROVIDE THE PERCENTAGE OF PALM SUBSTITUTIONS FOR
 REQUIRED TREES NOT EXCEEDING 35% PER SECTION 94-442(D).
  
 5. INDICATE THE 5 FOOT LANDSCAPE BUFFER LOCATIONS ON
 THE SITE PLAN AND LANDSCAPE PLAN ADJACENT TO ALL
 PROPERTY LINES FOR THE PARCEL.
  
 6. THE NONCONFORMING EAST BUFFER CAN BE IMPROVED BY
 ELIMINATING THE WHEEL STOPS AND MOVING THE CURB TO
 PROVIDE 16 FOOT PAVED STALL AND ADD PERVIOUS OVERHANG
 AREA. THIS WILL ALSO HELP REDUCE THE IMPERVIOUS AREA
 THAT IS VERY CLOSE TO THE LIMIT. CHECK OTHER AREAS
 ALONG THE NORTH BUFFER FOR POSSIBLE ADJUSTMENT.
  
 7. CHECK CALCULATIONS FOR THE REQUIRED TREES FOR BUFFER
 SEGMENTS IN THE PERIMETER BUFFER REQUIREMENT CHART AND
 LIST LINEAR FOOTAGE OF EACH PROPERTY LINE SEGMENT
 MEASURED ALONG THE CENTERLINE OF EACH BUFFER, ROUNDING
 UP FOR ANY PORTION LEFT AFTER DIVIDING BY THE REQUIRED
 30 FOOT LENGTHS. SOUTH BUFFER IS 6 TREES REQUIRED, AND
 WEST BUFFER IS 5 TREES REQUIRED. SEE SECTION 94-443 (B)
 FOR THE BUFFERS ADJACENT TO NON-RESIDENTIAL AND PUBLIC
 THOROUGHFARES.
  
 8. PROVIDE CALCULATION FOR BUFFER LENGTHS WITH ACCESS
 DRIVEWAYS TO SHOW THEY DO NOT EXCEED 25% INTERRUPTION
 FOR VEHICULAR ACCESS AS REQUIRED BY SECTION 94-443(B).
  
 9. PROVIDE THE REQUIRED AND PROVIDED LINEAR FOOTAGE OF
 LANDSCAPE AREA ADJACENT TO EACH BUILDING.
  
 10. ADD ANY EXISTING TREES AND PALMS TO THE PLANT LIST
 AND COUNT THEM TOWARD THE REQUIRED TREES.
  
 11. SECTION 94-443(C)(3) REQUIRES THAT A MINIMUM OF 75
 PERCENT OF ALL TREES THAT ARE REQUIRED TO BE PLANTED
 WITHIN THE INTERIOR OF AN OFF STREET PARKING AREA SHALL
 BE CATEGORY 1 SHADE TREES. SHOW THE REQUIRED NUMBER OF
 TREES AND THE PERCENTAGE OF CATEGORY 1 TREES PROVIDED
 FOR THE REQUIRED LANDSCAPE AREAS.
  
 12. PROVIDE AN EXHIBIT SHOWING THE PARKING AREA SURFACE
 CALCULATIONS, PARKING SPACE AREAS AND LANDSCAPE AREAS
 PROVIDED TO DEMONSTRATE COMPLIANCE WITH SECTIONS 94-443
 (C)(3) AND (4), FOLLOWING THE AREA CLASSIFICATIONS AS
 SHOWN IN FIGURE XIV-1.
 ? PARKING SPACES SHADED AS ONE AREA, SHOW TOTAL SPACES
 TIMES 10 SQ FT PER SPACE. PROVIDE TOTAL
 ? ALL OTHER PAVED AREAS SHADED DIFFERENTLY AND TOTAL
 SQUARE FOOTAGE. DIVIDE BY 100 AND MULTIPLY BY 4 SQ FT.
 PROVIDE TOTAL.
 ? TOTAL THESE 2 SQUARE FOOTAGE AMOUNTS FOR THE REQUIRED
 SQUARE FOOTAGE.
 ? SHOW ALL INTERIOR LANDSCAPE AREAS AS A DIFFERENT
 SHADE AND SHOW PROVIDED SQUARE FOOTAGE.
  
 13. DIMENSION ALL INTERIOR AND TERMINAL LANDSCAPE
 ISLANDS ON THE SITE PLAN TO SHOW THE MINIMUM 8 FEET
 WIDTH OF THE LANDSCAPE AREA IS AT LEAST 8 FEET FOR ALL
 NEW ISLANDS. TERMINAL ISLANDS ADJACENT TO A LANDSCAPE
 BUFFER CAN COUNT THE 5 FEET OF BUFFER BUT MUST ADD 3
 FEET OF LANDSCAPE AREA TO ACHIEVE THE REQUIRED 8 FEET
 WIDTH WITHIN CURB.
  
 14. TERMINAL LANDSCAPE ISLAND AND TREE IS MISSING AT
 THE SOUTHEAST CORNER ADJACENT TO MADDOCK ST.
 15. PROVIDE LOCATIONS AND SCREENING FOR ALL ABOVE
 GROUND UTILITY VALVES, BACKFLOW PREVENTERS, A/C UNITS,
 AND FPL TRANSFORMERS.
  
 16. PROVIDE THE PERCENTAGE TO BASED ON THE PLANT LIST
 TO SHOW COMPLIANCE WITH SECTION 94-445 L. PLANT
 SPECIES. A MINIMUM OF 60 PERCENT OF PLANT MATERIAL
 ADDED SHALL BE FLORIDA NATIVE OR DROUGHT TOLERANT
 SPECIES SELECTED FROM THE CITY LIST OR THE LIST OF
 SPECIES IN THE MOST RECENT EDITION OF SOUTH FLORIDA
 WATER MANAGEMENT DISTRICT WATERWISE SOUTH FLORIDA
 LANDSCAPES.
  
 CONDITIONS OF APPROVAL
 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON
 THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE
 SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT
 SERVICES DEPARTMENT, PLANNING DIVISION.
  