| 2021-04-01 09:06:58 | SEE NEW COMMENTS UNDER OLD COMMENTS THAT ARE MARKED AS |
| | SATISFIED/NOT SATISFIED/ PARTIALLY SATIFISFIED. IF |
| | MARKED AS "CONDITION OF APPROVAL", THESE ITEMS WILL BE |
| | LISTED AS CONDITIONS OF APPROVAL FOR SITE PLAN AND CAN |
| | BE HANDLED THROUGH BUIDLING PERMIT REVIEW. |
| | |
| | GENERAL COMMENTS/ARCHITECTURAL: |
| | 1. SATISFIED. |
| | 2. SATISFIED, SEE PROVISOS FOR BUILDING PERMIT. BY |
| | ZONING REGULATIONS FOR LD-4-12, A 5? SETBACK IS |
| | REQUIRED ALONG THE SIDE INTERIOR/REAR SETBACK (EASTERN |
| | PROPERTY LINE) FOR SOUTH BUILDING (LD-4-12 TABLE |
| | IV-52). HOWEVER, EXISTING LOFTIN PHASE I PARKING GARAGE |
| | IS BUILT RIGHT UP TO INTERIOR SIDE SETBACK. PER THE |
| | DECLARATION OF RESTRICTION IN ORB 28411 PG. 1108, AN |
| | ADDITIONAL SETBACK MAY BE REQUIRED FOR THE PROPOSED |
| | BUILDING FROM THE EDGE GARAGE. THE REQUIRED SETBACK |
| | DEPENDS ON THE PERCENTAGE OF OPENINGS ON THE PROPOSED |
| | STRUCTURE?S EAST FA?ADE |
| | 3. SATISFIED. |
| | 4. SATISFIED. |
| | 5. NOT SATISFIED. THERE WAS A BUS SHELTER ON THE SOUTH |
| | PORTION OF PHASE II THAT SHOULD NOT HAVE BEEN REMOVED |
| | UNTIL PHASE II WAS CONSTRUCTED, WHEN A REPLACEMENT |
| | SHELTER WAS TO BE CONSTRUCTED ALONG THE NORTH BUILDING |
| | STREET. THE SHELTER WAS REMOVED AT SOME POINT, AND |
| | NEVER REPLACED. A BUS SHELTER SHALL BE CONSTRUCTED AS |
| | PART OF THIS PHASE II PROCESS. PLEASE CONSTRUCT IN |
| | ARCHITECTURALLY COMPATIBLE DESIGN. PALM TRAN PREFERS |
| | THE SHELTER REMAIN ON THE BLOCK BETWEEN EUCALYPTUS AND |
| | 8TH, WITHIN PROXIMITY TO THE EXISTING BUS STOP POLE. |
| | 6. SATISFIED. |
| | 7. SATISFIED. |
| | 8. SATISFIED. |
| | 9. SATISFIED. |
| | 10. PARTIALLY SATISFIED. PLEASE PROVIDE FOLLOWING |
| | EXHIBITS: |
| | A. ACTIVE USE |
| | B. FOOTPRINT |
| | C. TRANSPARENCY |
| | D. PLANAR BREAK |
| | E. HORIZONTAL ELEMENTS |
| | F. FAR |
| | THE TRASH ROOMS DO NOT COUNT TOWARDS FAR (SHEET A-1.1). |
| | TRANSPARENCY IS BASED ON LINEAR FEET, NOT SF. PLEASE |
| | UPDATE IN TABLE ON SHEET A-1.8. |
| | THE STAIRWAY ON 8TH STREET AND THE TRASH ROOM ON |
| | EUCALYPTUS STREET WOULD NOT COUNT AS ACTIVE USE. |
| | PLEASE UPDATE THE PERCENTAGE OF HORIZONTAL PROJECTION |
| | ON EUCALYPTUS STREET ON SHEET A-1.9. |
| | 11. SATISFIED. |
| | 12. SATISFIED. |
| | 13. PARTIALLY SATISFIED. PLEASE INCLUDE FOLLOWING DATA |
| | IN SITE DATA TABLE: |
| | A. BUILDING FOOTPRINT PERCENTAGE ? SEE TABLES IV-51 AND |
| | IV-52 AT END OF SECTION 94-134 |
| | SEE NEW COMMENT #56 |
| | 14. SATISFIED. |
| | 15. SATISFIED. |
| | 16. PARTIALLY SATISIFIED. THE 4 BICYCLE PARKING SPACES |
| | (1 PER 100? OF FRONTAGE) APPEARS TO BE TOO FEW. THE |
| | REQUIREMENT IS PER ALL STREET FRONTAGES (NORTH DIXIE |
| | HIGHWAY, EUCALYPTUS STREET, 8TH STREET). THESE BIKE |
| | PARKING SPACES NEED TO BE ON THE ROW OR ACCESSIBLE BY |
| | THE GENERAL PUBLIC (SEE BICYCLE PARKING GUIDELINES |
| | PREVIOUSLY SENT BY EMAIL). PLEASE PROVIDE BICYCLE RACK |
| | SPECS |
| | REPEAT COMMENT: PLEASE PROVIDE BICYCLE RACK SPECS. |
| | PLEASE SHOW THE BICYCLE RACKS WITHIN THE ROW ON THE |
| | SITE PLAN |
| | 17. SATISFIED. |
| | 18. PARTIALLY SATISFIED. PLEASE PROVIDE GUEST PARKING |
| | AT RATE OF 1/20 REQUIRED MINIMUM PARKING SPACES (FOR |
| | ALL UNITS INCLUDING MICRO) AND INCLUDE IN PARKING DATA |
| | TABLE |
| | GUEST PARKING BASED ON REQUIRED MINIMUM PARKING NOT |
| | PROVIDED. |
| | 19. SATISFIED. |
| | 20. SATISFIED. |
| | 21. PARTIALLY SATISFIED. REQUIRED BIKE PARKING FOR |
| | MICROUNITS (FOR LESS THAN 13 MICROUNITS) IS ONE BIKE |
| | PARKING SPACE PER UNIT. PLEASE INCLUDE IN BIKE PARKING |
| | TABLE ? ONLY APPLIES TO THE 8 MICROUNITS, THE OTHERS |
| | FALL UNDER THE 1/15 PARKING SPACE REQUIREMENT. ALL |
| | BICYCLE PARKING FOR RESIDENTIAL USE SHOULD BE IN A |
| | SECURE AND COVERED LOCATION (INSIDE PARKING GARAGE IS |
| | FINE, BUT PLEASE ILLUSTRATE HOW BEING SECURED) |
| | PER CITY BICYCLE RACK SPECS, 24?? IS REQUIRED BETWEEN A |
| | WALL AND A BIKE RACKS, 30? IS REQUIRED BETWEEN EACH |
| | BICYCLE RACK, WITH A CENTER AISLE OF 36?. THE PROPOSED |
| | BICYCLE RACK ROOM WOULD NOT BE ABLE TO FIT THE NUMBER |
| | OF RACKS THAT IS REQUIRED |
| | 22. CONDITION OF APPROVAL: PLEASE NOTE, TRANSIT FEE |
| | (TROLLEY) CONTRIBUTION FEE PER SECTION 94-106(A)(8A)- |
| | CONTRIBUTION IS $10 PER MICROUNIT PER MONTH |
| | 23. PARTIALLY SATISFIED. PLEASE PROVIDE LOS FOR TRASH |
| | COLLECTION TO DETERMINE REQUIRED COMPACTORS/DUMPSTERS |
| | WITHIN PROPOSED TRASH ROOM. HOW IS TRASH COLLECTION |
| | WORKING FOR SOUTH BUILDING? PLEASE SPEAK TO MATT HEJAZI |
| | REGARDING LOS AND NEEDED COMPACTORS/DUMPSTERS AND |
| | LOCATION FOR DUMPSTER/COMPACTOR STAGING ON PICK UP DAY |
| | IS THE TEMPORARY LOADING/UNLOADING FOR THE TRASH |
| | PICKUP? PLEASE CLARIFY. PLEASE REMOVE THE CURB CUT FOR |
| | THE TRASH ROOMS AND INCLUDE A DROP CURB INSTEAD. |
| | 24. PARTIALLY SATISFIED. THE EAST ELEVATION OF THE |
| | SOUTHERN BUILDING (SECTION 7 ON PAGE A-3.7) DOES NOT |
| | SEEM TO MATCH THE FLOOR PLANS. THERE ARE SOME GROUND |
| | FLOOR ELEVATIONS THAT HAVE THE APPEARANCE OF COMMERCIAL |
| | WINDOWS BUT ARE RESIDENTIAL UNITS. PLEASE UPDATE |
| | ELEVATIONS TO REFLECT SITE PLAN |
| | SOME OF THE GROUND FLOOR UNITS HAVE HIGH WINDOWS THAT |
| | EXTEND TO THE GROUND, PLEASE CONFIRM THAT THESE |
| | ELEVATIONS MATCH THE PROPOSED WINDOW TYPES ALONG 8TH |
| | STREET (TWO MIDDLE WINDOWS AND WESTERN WINDOW ON NORTH |
| | BUILDING), THE THREE NORTHERN GROUND FLOOR WINDOWS |
| | ALONG NORTH DIXIE HIGHWAY (NORTH BUILDING), THE GROUND |
| | FLOOR UNITS ON EUCALYPTUS STREET IN THE SOUTHERN |
| | BUILDING, AND THE EASTERN THREE HIGH WINDOWS ON THE |
| | SOUTH ELEVATION OF THE SOUTH BUILDING. STAFF JUST WANTS |
| | TO CONFIRM THAT THE WINDOWS ARE MATCHING WHAT IS SHOWN |
| | ON THE FLOOR PLAN FOR THESE UNITS. |
| | 25. SATISFIED. |
| | 26. PARTIALLY SATISFIED. ON FACADES ENCLOSING |
| | NON-ACTIVE USE (PARKING GARAGE), ARCHITECTURAL |
| | TREATMENT SHALL BE PROVIDED NOT TO INCLUDE PAINT AND |
| | FAUX TREATMENTS, MATERIAL APPLICATIONS LESS THAN 4 |
| | INCHES IN HEIGHT, DEPTH OR WIDTH, OR BUILDING SIGNS. |
| | ARCHITECTURAL DESIGN SHALL BE INTEGRATED WITH DESIGN OF |
| | ADJACENT ACTIVE USE FACADES. PLEASE PROVIDE ADDITIONAL |
| | ARCHITECTURAL TREATMENT ON PARKING GARAGE. SEE |
| | DEFINITION IN SECTION 94-109. EVALUATE MEANS OF |
| | REDUCING IMPACT OF RAMP FACING EUCALYPTUS STREET |
| | PLEASE EXAMINE INCLUDING THE WINDOW DESIGN TO MATCH THE |
| | WINDOW DESIGN ON THE RESIDENTIAL FA?ADE. PLEASE EXAMINE |
| | ADDITIONAL ARCHITECTURAL TREATMENT AT THE PARKING |
| | GARAGE ENTRANCES |
| | 27. SATISFIED. |
| | 28. SATISFIED. |
| | 29. SATISFIED. |
| | 30. PARTIALLY SATISFIED. PLEASE PROVIDE: |
| | A. SATISFIED |
| | B. SATISFIED |
| | C. NOT SATISFIED. GROUND FLOOR COLORED, CONTEXTUAL |
| | RENDERINGS WITH PLANTING HEIGHT LANDSCAPE |
| | D. PARTIALLY SATISFIED. MATERIAL SAMPLE IMAGERY AND |
| | MATERIAL SPECIFICATION DETAIL ? PLEASE PROVIDE SOME |
| | IMAGERY OF ACTUAL MATERIALS |
| | E. SATISFIED |
| | ENGINEERING |
| | 31. SATISFIED |
| | 32. SATISFIED |
| | 33. SATISFIED. |
| | 34. PARTIALLY SATISFIED. PLEASE PROVIDE UPDATED CROSS |
| | SECTIONS INCLUDING: |
| | A. SIDEWALK SECTIONS ADJACENT TO PARALLEL PARKING |
| | SPACES |
| | B. SIDEWALK SECTIONS ADJACENT TO RETAIL/COMMERCIAL DOOR |
| | ENTRANCES |
| | C. SIDEWALK SECTIONS ADJACENT TO RESIDENTIAL UNITS |
| | THE PROPOSED SLOPE OF PORTIONS OF THE SIDEWALK IN CROSS |
| | SECTION A-A AND B-B ARE TOO HIGH. MAXIMUM OF 2% SLOPE |
| | SHALL BE MAINTAINED ALONG SIDEWALKS AND FROM PARALLEL |
| | PARKING TO THE SIDEWALK. REQUIRED SLOPE CHANGES SHALL |
| | BE CAPTURED INTERNAL TO BUILDING. |
| | 35. NOT SATISFIED. ALL LARGE GRADING CHANGES SHALL BE |
| | CAPTURED WITHIN BUILDING NOT WITHIN SIDEWALK OR ROW |
| | 36. NOT SATISFIED |
| | 37. SATISFIED |
| | 38. SATISFIED |
| | 39. CONDITION OF APPROVAL: THE DECLARATION OF EASEMENTS |
| | (ORB 28271 PAGE 144) MAY HAVE TO BE UPDATED AND AMENDED |
| | AS NECESSARY SUBJECT TO CITY ENGINEERING AND CITY LEGAL |
| | REVIEW |
| | 40. PARTIALLY SATISFIED. PLEASE PROVIDE PHOTOMETRIC |
| | PLAN FOR ALL ROW INCLUDING PUBLIC OPEN SPACE, GARAGE |
| | ENTRANCES AND EXITS, ALL SIDEWALKS, ANY SIDEWALKS |
| | LEADING INTO BUILDING OR GARAGE AND INCLUDE LIGHT POLE |
| | SPECS |
| | PLEASE INCLUDE PHOTOMETRIC ANALYSIS FOR PUBLIC OPEN |
| | SPACE. PLEASE INCLUDE STREET TREES ON PHOTOMETRIC PLAN |
| | TO DETERMINE ANY CONFLICT WITH STREET TREES AND/OR |
| | UNDERGROUND UTILITY LINES. |
| | 41. PARTIALLY SATISFIED. PLEASE INDICATE LOCATION OF |
| | ALL ABOVE GROUND, ROOF MOUNTED, UNDERGROUND AND WALL |
| | MOUNTED UTILITIES. PLEASE PLACE OUTSIDE ROW WITHIN SIDE |
| | INTERIOR LOT LINES (IF POSSIBLE PER UTILITY |
| | REQUIREMENTS) AND SCREEN TO BEST EXTENT POSSIBLE WITH |
| | LANDSCAPE OR STRUCTURAL ARCHITECTURALLY COMPATIBLE |
| | COVERING. SUBJECT TO REVIEW BY MARK HURLEY (FOR |
| | DOMESTIC BACKFLOW AND WATER METERS), RAY CARANCI FOR |
| | IRRIGATION METERS, TRACY WARD FOR STORMWATER DRAINAGE, |
| | AND ALL APPLICABLE DEPARTMENTS |
| | PLEASE RELOCATE WATER METER WITH RPZ FROM OUTSIDE AREAS |
| | THAT ARE BEING TREATED AS PUBLIC OPEN SPACE (CANNOT |
| | CONTAIN UTILITIES OR MECHANICAL EQUIPMENT). PLEASE |
| | COORDINATE WITH LANDSCAPE PLAN AS IT SEEMS STREET TREES |
| | ARE PROPOSED DIRECTLY ABOVE UNDERGROUND LINES AND |
| | DIRECTLY UNDER OVERHEAD LINES. COORDINATE WITH MARK |
| | HURLEY, RAY CARANCI, AND ZONING. |
| | 42. SATISFIED. |
| | LANDSCAPE: |
| | 43. SATISFIED |
| | 44. SATISFIED |
| | 45. PARTIALLY SATISFIED. PLEASE INDICATE WHICH TYPE OF |
| | PUBLIC OPEN SPACE, SEMI-PUBLIC OPEN SPACE AND PRIVATE |
| | OPEN SPACE IS BEING PROPOSED BASED ON THE PERMITTED |
| | TYPES IN THE ZONING DISTRICT (TABLE IV-6), AND MAKING |
| | SURE THAT THE SELECTED TYPES MEETS THE DEFINITION |
| | (SECTION 94-109) OF EACH SPECIFIC OPEN SPACE TYPE |
| | (GARDEN, TERRACE, GARDEN PLAZA, ETC.), AND THAT THE |
| | SPECIFIC REQUIREMENTS OF EACH OPEN SPACE TYPE (TABLE |
| | IV-7) ARE MET WITHIN THAT AREA. |
| | PLEASE LABEL INDIVIDUAL AREAS WITH THE TYPE ASSOCIATED. |
| | FOR EXAMPLE, WHICH AREA IS CONSIDERED ?GARDEN? PRIVATE |
| | OPEN SPACE? |
| | 46. SATISFIED. THE PORTION OF LANDSCAPE BETWEEN THE |
| | PROPOSED PARKING GARAGE AND PROPERTY LINE WOULD NOT |
| | MEET ANY OF THE DEFINITIONS OF TYPES OF PRIVATE OPEN |
| | SPACE. CHECK PROPERTY LINE PLACEMENT HERE AS THE PHASE |
| | I PARKING GARAGE APPEARS ON PAPA TO BE RIGHT UP ON THE |
| | PROPERTY LINE |
| | 47. SATISFIED |
| | 48. NOT SATISFIED. PLEASE ILLUSTRATE HOW THE PROPOSED |
| | PUBLIC OPEN SPACE AT THE SOUTH SIDE OF THE SOUTH |
| | BUILDING WILL CONNECT TO THE EXISTING AREA. PLEASE |
| | REMOVE THE PROPOSED BUTTONWOOD SHRUB TO CONNECT HE OPEN |
| | SPACES TOGETHER TO IMPROVE THE EXISTING OPEN SPACE AND |
| | PROVIDE FOR PEDESTRIAN CONNECTIVITY FOR THE PUBLIC |
| | AREAS. EXPLORE REMOVING THE FENCE ON THE LOFTIN PHASE I |
| | PROPERTY WITHIN THIS AREA TO BETTER CONNECT |
| | AREA HAS NOT BEEN DESIGNED IN A MANNER TO CONNECT WITH |
| | EXISTING OPEN SPACE. THE DESIGN SEEMS TO BE CATERED |
| | TOWARDS THE PRIVATE SEATING OF THE RETAIL TENANT ON THE |
| | GROUND FLOOR, NOT FOR PUBLIC USE. NEEDS TO BE MORE OPEN |
| | TO SIDEWALK AND PUBLIC |
| | 49. SATISFIED |
| | 50. SATISFIED |
| | 51. SATISFIED |
| | 52. SATISFIED |
| | NEW COMMENTS MARCH 30, 2021: |
| | GENERAL: |
| | 53. PLEASE ADD TURN AROUND PARKING SPACE ON TOP LEVEL |
| | AND AT DEAD END BOTTOM LEVEL. TURN AROUND SPACES |
| | REQUIRED FOR DEAD END ROWS. |
| | 54. THERE IS PARKING ON THE BOTTOM FLOOR LABELED 7 |
| | PARKING SPACES, BUT STAFF COUNTS 10. |
| | 55. THE PUBLIC OPEN SPACE AT THE NORTHWEST CORNER OF |
| | THE SOUTHERN BUILDING MAY NEED TO EXTEND A BIT FURTHER |
| | SOUTH TO MEET THE REQUIREMENT OF 900 SF (PLEASE |
| | DISREGARD IF ALREADY MEETING 900 SF). PLEASE INCLUDE |
| | THE SF OF EACH INDIVIDUAL SECTION OF PRIVATE, PUBLIC |
| | AND SEMI PUBLIC OPEN SPACE. |
| | 56. PLEASE INCLUDE THE PEDESTRIAN BRIDGES TOWARDS THE |
| | BUILDING FOOTPRINT CALCULATIONS. |
| | 57. PLEASE INCLUDE PERCENTAGES OF BUILDING FOOTPRINT |
| | PER BASE, PODIUM AND TOWER AS PERMITTED IN LD-4 AND |
| | LD-10 WITHIN THE SITE DATA TABLE AND ON SHEET A-1.5 ? |
| | A-1.7. |
| | 58. THE TURNING RADIUS OF THE PARKING SPACES |
| | IMMEDIATELY WITHIN THE PARKING GARAGE ENTRANCES MIGHT |
| | BE TOO TIGHT, CONFIRM WITH TRAFFIC ENGINEER. |
| | 59. THE SITE DATA TABLE INDICATES THE INCLUSION OF |
| | MICROUNITS, HOWEVER, NONE OF THE UNITS MEET THE |
| | REQUIREMENT FOR MICROUNIT SIZE. MICROUNITS ARE BETWEEN |
| | 300 AND 549 SF. PLEASE REVISE SF OF UNITS, OR REVISE |
| | SITE DATA TABLE AND PARKING IF NO MICROUNITS ARE BEING |
| | INCLUDED. THE AMENITY SPACE IS SHOWN AT A HIGHER |
| | ELEVATION THAN THE SIDEWALK LEVEL |
| | 60. PLEASE INCLUDE THE AVERAGE UNIT SIZE. MINIMUM |
| | AVERAGE UNIT SIZE IS 800 SF |
| | 61. IF MICROUNITS ARE INCLUDED, A MICROMOBILITY STATION |
| | IS REQUIRED AT A SIZE OF 8?X22? AND A CONDUIT (2? |
| | SCHEDULE 40 PVC) SHALL BE PROVIDED TO THE POWER SOURCE |
| | WITH AN ELECTRICAL PULL BOX (240V CIRCUIT). |
| | 62. |
| | |
| | CIVIL: |
| | 63. PLEASE CLARIFY IF BFP AND DDCV ILLUSTRATED ON THE |
| | SOUTH SIDE OF EUCALYPTUS STREET ARE EXISTING OR IF ANY |
| | NEW APPURTENANCES ARE PROPOSED. IF PROPOSED, NEED TO |
| | CHECK WITH FIRE CHIEF AND PUBLIC UTILITIES WHETHER NEW |
| | ITEMS CAN BE PLACED OFF SITE. |
| | 64. PLEASE RELOCATE THE SPEED SIGN ON DIXIE HIGHWAY |
| | (ADJACENT TO NORTHERN BUILDING) CLOSER TO THE CURB |
| | LINE. |
| | 65. THE PROPOSED THREE PHASE TRANSFORMERS ADJACENT TO |
| | THE PARKING GARAGE ON EUCALYPTUS STREET CANNOT BE |
| | PROPOSED IN THE CENTER OF THE SIDEWALK. PLEASE RELOCATE |
| | TO APPROPRIATE LOCATION, CANNOT BE WITHIN THE MINIMUM |
| | REQUIRED SETBACKS FROM STREET FRONTAGES. TRANSFORMERS |
| | AND OTHER EQUIPMENT CANNOT PROJECT MORE THAN FOUR FEET |
| | INTO A REQUIRED SIDE OR REAR SETBACK. |
| | 66. PLEASE PROVIDE EXHIBIT OF WATER METER AREAS (CANNOT |
| | BE LOCATED WITHIN PUBLIC OPEN SPACE), AND AN EXHIBIT OF |
| | THE AREAS PROPOSED TO HAVE DDCV AND DOMESTIC WATER |
| | SERVICE. |
| | 67. THE SOUTHERN BUILDING FLOOR PLAN ON THE CIVIL PLANS |
| | DO NOT MATCH THE LATEST ARCHITECTURAL FLOOR PLANS. |
| | PLEASE UPDATE. |
| | 68. THE LINE OF THE REQUIRED SETBACK ON THE CIVIL PLANS |
| | DO NOT MATCH THE REQUIRED SETBACK. PLEASE COORDINATE |
| | WITH ARCHITECTURAL PLANS. |
| | |
| | |
| | LANDSCAPE: |
| | 69. PLEASE LOOK AT MEANS OF DESIGNING THE PUBLIC OPEN |
| | SPACES, INCLUDING THE PRIVATE OPEN SPACE THAT IS ON THE |
| | GROUND FLOOR AND DESIGNED AS PUBLIC OPEN SPACE, IN A |
| | WAY THAT WILL PROVIDE AN AREA FOR THE PUBLIC ENJOYMENT. |
| | PLEASE EVALUATE USE OF LANDSCAPING, HARDSCAPE AND |
| | ORIENTATION OF LINEAR SEATING. |
| | 70. THE PROPOSED LANDSCAPE CONFLICTS WITH OVERHEAD |
| | POWER LINES, PLEASE COORDINATE WITH RAY CARANCI AND FPL |
| | 71. PLEASE PROVIDE LANDSCAPE SCREENING AROUND THE |
| | PROPOSED TRANSFORMERS, WATER METER, DDCV AND ALL ABOVE |
| | GROUND UTILITIES. FROM UTILITIES PERSPECTIVE, BACKFLOW |
| | ASSEMBLIES NEED 18? CLEARANCE FOR MAINTENANCE AND |
| | TESTING. ENGINEERING SUGGESTS LANDSCAPE SCREENING TO |
| | PREVENT TAMPERING WITH BACKFLOW ASSEMBLIES. |
| | 72. PLEASE RELOCATE THE BENCHES PROPOSED WITHIN THE |
| | PUBLIC OPEN SPACE AREAS TO NOT DIVERT THE SIDEWALK |
| | PATH. |
| | 73. PLEASE INCORPORATE LANDSCAPE AROUND ALL ABOVE |
| | GROUND UTILITIES INCLUDE TRANSFORMER LOCATIONS. THE |
| | PLANS SHOW THE UTILITIES BUT THERE ARE SOME CONFLICTS |
| | WITH PROPOSED LANDSCAPING AND UTILITIES, BOTH ABOVE AND |
| | UNDER GROUND UTILITIES. |
| | 74. PLEASE ENSURE THAT PROPOSED LANDSCAPE WITHIN FPL |
| | EASEMENT ON DIXIE HIGHWAY WILL BE PERMITTED. COORDINATE |
| | WITH FPL AND RAY CARANCI, LANDSCAPE PLANNER AT THE |
| | CITY. |
| | ARCHITECTURAL: |
| | 75. THE SECOND FLOOR WINDOW AT THE SOUTHERN CORNER OF |
| | THE SOUTHERN BUILDING?S EAST ELEVATION (INTERNAL) DOES |
| | NOT SEEM TO MATCH THE FLOOR PLAN. |
| | 76. THE SECOND FLOOR WINDOW AT THE SOUTH END OF THE |
| | WEST ELEVATION (SOUTHERN BUILDING) DOES NOT APPEAR TO |
| | MATCH THE WINDOW PROPOSED IN THE FLOOR PLAN. |
| | 77. ALONG THE EAST ELEVATION OF THE SOUTHERN BUILDING, |
| | THE FLOOR PLAN ILLUSTRATES A WATER ROOM. THE ELEVATION |
| | SHOWS A WINDOW ON THIS ROOM BUT THE WINDOW IS NOT |
| | REFLECT ON THE FLOOR PLAN. |
| | 78. THE LOCATION OF THE STAIRWAY FOR THE NORTHERN MOST |
| | GROUND FLOOR UNIT ON THE WEST ELEVATION OF THE SOUTHERN |
| | BUILDING DOES NOT MATCH THE FLOOR PLAN. |
| | 79. THERE IS A VERTICAL ROW OF WINDOWS AT THE NORTH |
| | CORNER OF THE WEST ELEVATION (SOUTHERN BUILDING) THAT |
| | DOES NOT APPEAR ON THE SITE PLAN. ALSO ON THE NORTH |
| | ELEVATION (8TH STREET) OF THE NORTHERN BUILDING. PLEASE |
| | UPDATE FLOOR PLANS TO REFLECT WINDOW OR UPDATE |
| | ELEVATION. IF THERE ARE NO WINDOWS PLEASE INCLUDE |
| | FENESTRATION |
| | 80. THE EAST ELEVATION OF THE SOUTHERN BUILDING SHOWS A |
| | GROUND FLOOR DOOR AT THE NORTH CORNER BUT THIS DOES NOT |
| | APPEAR ON THE FLOOR PLAN. |
| | 81. FENESTRATION IS REQUIRED ALONG THE GROUND FLOOR AND |
| | PODIUM OF THE NORTHERN PORTION OF THE EAST ELEVATION, |
| | PER TABLE IV-4. BLANK WALLS ARE NOT PERMITTED. |
| | 82. PLEASE UPDATE THE BUILDING SECTIONS TO SHOW THE |
| | TRAVEL PAVEMENT AND SIDEWALK ON ALL SIDES OF THE |
| | PROPOSED STRUCTURE. PLEASE ACCURATELY SHOW THE TRAVEL |
| | LANE, CURB AND SIDEWALK ELEVATIONS ON SECTIONS. |
| | 83. PLEASE SHOW THE GAS STATION ON DIXIE BOULEVARD |
| | (NORTH OF 8TH STREET) ON THE CONTEXTUAL ELEVATIONS. |
| | 84. PLEASE INCLUDE THE PUBLIC SPACE WITHIN RENDERINGS. |
| | PROPOSED PROVISOS: |
| | 1. AN AMENDMENT TO HE RESTRICTIVE COVENANT MAY BE |
| | REQUIRED IF NECESSARY PENDING ENGINEERING AND LEGAL |
| | REVIEW |
| | 2. ALL ABOVE GROUND UTILITIES SHALL BE LOCATED WITHIN |
| | SIDE INTERIOR LOT LINES IF POSSIBLE AND SCREENED BY |
| | LANDSCAPE, HARDSCAPE OR ARCHITECTURALLY COMPATIBLE |
| | SCREENING. FIELD LOCATES SHALL BE SUBJECT TO ZONING |
| | APPROVAL |
| | 3. ALL PARKING GARAGE CEILINGS SHALL BE PAINTED |
| | (INCLUDING CEILING PIPES AND UTILITIES) TO A DEPTH OF |
| | 20 FEET FROM ENTRANCES/EXITS AND FROM ALL OPENINGS |
| | 4. APPLICANT SHALL ENTER MAINTENANCE AGREEMENT WITH |
| | CITY FOR ALL STREETSCAPE UPGRADES (TREES, TREE GRATES, |
| | BENCHES, LANDSCAPE, ETC) WITHIN THE CITY OWNED ROW TO |
| | INCLUDE BUS SHELTER |
| | 5. THE SIDEWALK SHALL BE KEPT LEVEL ACROSS CURB CUTS |
| | 6. A SIDEWALK EASEMENT WILL BE REQUIRED FOR PUBLIC |
| | SIDEWALK WITHIN PRIVATE PROPERTY |
| | 7. PER THE DECLARATION OF RESTRICTION IN ORB 28411 PG. |
| | 1108, AN ADDITIONAL SETBACK MAY BE REQUIRED FOR THE |
| | PROPOSED BUILDING FROM THE EDGE GARAGE. THE REQUIRED |
| | SETBACK DEPENDS ON THE PERCENTAGE OF OPENINGS ON THE |
| | PROPOSED STRUCTURE?S EAST FA?ADE |
| | 8. 20? STACKING DISTANCE REQUIRED IF PARKING GARAGE |
| | WILL BE GATED AND THE PARKING FOR RETAIL NEEDS TO BE |
| | PUBLICLY ACCESSIBLE |
| | 9. PLEASE NOTE, TRANSIT FEE (TROLLEY) CONTRIBUTION FEE |
| | PER SECTION 94-106(A)(8A)- CONTRIBUTION IS $10 PER |
| | MICROUNIT PER MONTH |
| | 10. THE DECLARATION OF EASEMENTS (ORB 28271 PAGE 144) |
| | MAY HAVE TO BE UPDATED AND AMENDED AS NECESSARY SUBJECT |
| | TO CITY ENGINEERING AND CITY LEGAL REVIEW |
| | 11. PLEASE WALL MOUNT ALL FDC ? SUBJECT TO APPROVAL BY |
| | CHIEF PETER LEDUC |
| | 12. FDOT PERMIT WILL BE REQUIRED FOR ALL ROW |
| | IMPROVEMENTS WITHIN DIXIE HIGHWAY |
| | |
| | |
| | LIZ LEVESQUE, URBAN DESIGN PLANNER |
| | [email protected], 561 822 1426 |
| | |
| | AFTER APRIL 2, 2021 PLEASE CONTACT: |
| | ANA MARIA APONTE, CITY URBAN DESIGNER |
| | 561 822 1439 |
| | [email protected] |
| |