| 2021-01-29 15:44:00 | GENERAL COMMENTS/ARCHITECTURAL : |
| | 1. PLEASE DISTINGUISH PROPERTY LINE FROM LD-4 ZONING |
| | LINE. THE EASTERN PROPERTY LINE OF THE SOUTHERN |
| | STRUCTURE LOT APPEARS TO BE SHOW IN AN INCORRECT |
| | LOCATION ON THE ARCHITECTURAL AND LANDSCAPE PLANS AND |
| | THE EXISTING PARKING GARAGE IS NOT SHOWN IN THE CORRECT |
| | LOCATION. BASED ON THE SURVEY, THE EAST PROPERTY LINE |
| | IS APPROX. 180 FEET FROM THE WESTERN PROPERTY LINE. THE |
| | EXISTING PHASE I PARKING GARAGE IS BUILT RIGHT UP TO |
| | THIS PROPERTY LINE. |
| | 2. BY ZONING REGULATIONS FOR LD-4-12, A 5? SETBACK IS |
| | REQUIRED ALONG THE SIDE INTERIOR/REAR SETBACK (EASTERN |
| | PROPERTY LINE) FOR SOUTH BUILDING (LD-4-12 TABLE |
| | IV-52). HOWEVER, EXISTING LOFTIN PHASE I PARKING GARAGE |
| | IS BUILT RIGHT UP TO INTERIOR SIDE SETBACK. PER THE |
| | DECLARATION OF RESTRICTION IN ORB 28411 PG. 1108, AN |
| | ADDITIONAL SETBACK MAY BE REQUIRED FOR THE PROPOSED |
| | BUILDING FROM THE EDGE GARAGE. THE REQUIRED SETBACK |
| | DEPENDS ON THE PERCENTAGE OF OPENINGS ON THE PROPOSED |
| | STRUCTURE?S EAST FA?ADE |
| | 3. PLEASE ADD STAIRS FOR GROUND FLOOR ACCESS TO THE |
| | RESIDENTIAL UNITS |
| | 4. A PEDESTRIAN ACCESS EASEMENT (ITEM NO. 10 ORB 28271 |
| | PAGE 144, ITEM H) EXISTS ON THE BOUNDARY SURVEY THAT |
| | CONNECTS THE ROW SIDEWALK TO THE GARAGE OF THE LOFTIN |
| | PHASE I STRUCTURE BUT THIS IS NOT INCORPORATED INTO THE |
| | PROPOSED DESIGN. PLEASE CLARIFY HOW ACCESS WILL REMAIN |
| | TO THIS PARKING GARAGE/UTILITY AREA |
| | 5. THERE WAS A BUS SHELTER ON THE SOUTH PORTION OF |
| | PHASE II THAT SHOULD NOT HAVE BEEN REMOVED UNTIL PHASE |
| | II WAS CONSTRUCTED, WHEN A REPLACEMENT SHELTER WAS TO |
| | BE CONSTRUCTED ALONG THE NORTH BUILDING STREET. THE |
| | SHELTER WAS REMOVED AT SOME POINT, AND NEVER REPLACED. |
| | A BUS SHELTER SHALL BE CONSTRUCTED AS PART OF THIS |
| | PHASE II PROCESS. PLEASE CONSTRUCT IN ARCHITECTURALLY |
| | COMPATIBLE DESIGN. PALM TRAN PREFERS THE SHELTER REMAIN |
| | ON THE BLOCK BETWEEN EUCALYPTUS AND 8TH, WITHIN |
| | PROXIMITY TO THE EXISTING BUS STOP POLE. |
| | 6. PLEASE EVALUATE LOCATION OF COLUMNS FOR PEDESTRIAN |
| | BRIDGE- THESE SHOULD BE LOCATED OUTSIDE THE MINIMUM |
| | SETBACK AND NOT WITHIN THE CITY ROW |
| | 7. 30% OF THE EXPOSED ROOF PARKING MUST BE COVERED WITH |
| | VEGETATED AREA, OR 30% OF COVERED STRUCTURES LIKE THE |
| | PROPOSED TRELLIS. THE PROPOSED TRELLIS COVERS |
| | APPROXIMATELY 13% OF THE EXPOSED ROOF. PLEASE EXPAND OR |
| | PROVIDE OTHER MEANS OF MEETING THE 30% REQUIREMENT (OR |
| | ALTERNATE MEANS OF ART MURAL PER SECTION |
| | 94-111(Q)(4)(D) |
| | 8. PLEASE SHOW DOUBLE STRIPING IN PARKING GARAGE AND |
| | INCLUDE PARKING LOT STRIPING DETAIL PER SECTION 94-485 |
| | 9. PLEASE SHOW OUTLINE OF BUILDINGS ON WEST SIDE OF |
| | DIXIE ON ALL PLANS |
| | 10. PLEASE PROVIDE FOLLOWING EXHIBITS: |
| | A. ACTIVE USE |
| | B. FOOTPRINT |
| | C. TRANSPARENCY |
| | D. PLANAR BREAK |
| | E. HORIZONTAL ELEMENTS |
| | F. FAR |
| | 11. PLEASE NOTE, PEDESTRIAN BRIDGES COUNT AS GBA |
| | 12. PLEASE PROVIDE A TABLE ILLUSTRATING BREAKDOWN OF |
| | SITE PLAN AREA WITH SPECIFIC ZONING/INCENTIVE ZONING |
| | WITH ALLOWABLE FAR PER SPECIFIC ZONING AND ALLOWABLE |
| | GSF PER AREA WITH A TOTAL (SIMILAR TO TABLE DONE IN |
| | 2013 FOR LOFTIN PHASE I AND II BY MSA ARCHITECTS). |
| | PLEASE INDICATE INCENTIVE ZONING IN SITE DATA TABLE |
| | 13. PLEASE INCLUDE FOLLOWING DATA IN SITE DATA TABLE: |
| | A. BUILDING FOOTPRINT PERCENTAGE ? SEE TABLES IV-51 AND |
| | IV-52 AT END OF SECTION 94-134 |
| | 14. PEDESTRIAN BRIDGE APPEARS TO TERMINATE INTO A |
| | RESIDENTIAL UNIT IN THE SOUTH BUILDING. PLEASE CLARIFY |
| | 15. WILL THE PARKING GARAGE BE GATED? PLEASE NOTE THAT |
| | A 20? STACKING DISTANCE FROM ROW IS REQUIRED AND THE |
| | PARKING FOR RETAIL NEEDS TO BE PUBLICLY ACCESSIBLE |
| | 16. THE 4 BICYCLE PARKING SPACES (1 PER 100? OF |
| | FRONTAGE) APPEARS TO BE TOO FEW. THE REQUIREMENT IS PER |
| | ALL STREET FRONTAGES (NORTH DIXIE HIGHWAY, EUCALYPTUS |
| | STREET, 8TH STREET). THESE BIKE PARKING SPACES NEED TO |
| | BE ON THE ROW OR ACCESSIBLE BY THE GENERAL PUBLIC (SEE |
| | BICYCLE PARKING GUIDELINES PREVIOUSLY SENT BY EMAIL). |
| | PLEASE PROVIDE BICYCLE RACK SPECS |
| | 17. PLEASE ADD LABELS ON INDIVIDUAL PARKING SPACES THAT |
| | WILL BE RESERVED FOR RETAIL AND FOR GUEST PARKING |
| | 18. PLEASE PROVIDE GUEST PARKING AT RATE OF 1/20 |
| | REQUIRED MINIMUM PARKING SPACES (FOR ALL UNITS |
| | INCLUDING MICRO) AND INCLUDE IN PARKING DATA TABLE |
| | 19. PLEASE UPDATE REQUIRED PARKING TABLE BASED ON |
| | MINIMUM AND MAXIMUM REQUIRED, NOT PROVIDED PARKING. |
| | REQUIRED PARKING FOR RESIDENTIAL USE IS MIN. 1/UNIT AND |
| | MAX. 2/UNIT. MICROUNITS IS MIN. 0/UNIT AND MAX |
| | 0.5/UNIT. RETAIL IS 2/1000 SF AND 4/1000 SF. PLEASE |
| | INCLUDE ADA PARKING REQUIRED AND PROVIDED PER LATEST |
| | BUILDING CODE REQUIREMENT |
| | 20. ONE OF THE PARKING ROWS ON FIRST FLOOR IS LABELED |
| | WITH 15 PARKING SPACES BUT STAFF COUNTS 13 |
| | 21. REQUIRED BIKE PARKING FOR MICROUNITS (FOR LESS THAN |
| | 13 MICROUNITS) IS ONE BIKE PARKING SPACE PER UNIT. |
| | PLEASE INCLUDE IN BIKE PARKING TABLE ? ONLY APPLIES TO |
| | THE 8 MICROUNITS, THE OTHERS FALL UNDER THE 1/15 |
| | PARKING SPACE REQUIREMENT. ALL BICYCLE PARKING FOR |
| | RESIDENTIAL USE SHOULD BE IN A SECURE AND COVERED |
| | LOCATION (INSIDE PARKING GARAGE IS FINE, BUT PLEASE |
| | ILLUSTRATE HOW BEING SECURED) |
| | 22. PLEASE NOTE, TRANSIT FEE (TROLLEY) CONTRIBUTION FEE |
| | PER SECTION 94-106(A)(8A)- CONTRIBUTION IS $10 PER |
| | MICROUNIT PER MONTH |
| | 23. PLEASE PROVIDE LOS FOR TRASH COLLECTION TO |
| | DETERMINE REQUIRED COMPACTORS/DUMPSTERS WITHIN PROPOSED |
| | TRASH ROOM. HOW IS TRASH COLLECTION WORKING FOR SOUTH |
| | BUILDING? PLEASE SPEAK TO MATT HEJAZI REGARDING LOS AND |
| | NEEDED COMPACTORS/DUMPSTERS AND LOCATION FOR |
| | DUMPSTER/COMPACTOR STAGING ON PICK UP DAY |
| | 24. THE EAST ELEVATION OF THE SOUTHERN BUILDING |
| | (SECTION 7 ON PAGE A-3.7) DOES NOT SEEM TO MATCH THE |
| | FLOOR PLANS. THERE ARE SOME GROUND FLOOR ELEVATIONS |
| | THAT HAVE THE APPEARANCE OF COMMERCIAL WINDOWS BUT ARE |
| | RESIDENTIAL UNITS. PLEASE UPDATE ELEVATIONS TO REFLECT |
| | SITE PLAN |
| | 25. PLEASE INCLUDE ACTUAL SCORING OR MATERIAL CHANGE ON |
| | THE CORNER ELEMENTS, NOT JUST PAINTED SCORING |
| | 26. ON FACADES ENCLOSING NON-ACTIVE USE (PARKING |
| | GARAGE), ARCHITECTURAL TREATMENT SHALL BE PROVIDED NOT |
| | TO INCLUDE PAINT AND FAUX TREATMENTS, MATERIAL |
| | APPLICATIONS LESS THAN 4 INCHES IN HEIGHT, DEPTH OR |
| | WIDTH, OR BUILDING SIGNS. ARCHITECTURAL DESIGN SHALL BE |
| | INTEGRATED WITH DESIGN OF ADJACENT ACTIVE USE FACADES. |
| | PLEASE PROVIDE ADDITIONAL ARCHITECTURAL TREATMENT ON |
| | PARKING GARAGE. SEE DEFINITION IN SECTION 94-109. |
| | EVALUATE MEANS OF REDUCING IMPACT OF RAMP FACING |
| | EUCALYPTUS STREET |
| | 27. PLEASE SHOW PROPERTY LINES ON ELEVATIONS |
| | 28. PLEASE REMOVE PEOPLE WALKING FROM ELEVATION A-3.3 |
| | (SIDE LOT LINE) TO SHOW THAT THIS IS AN INTERIOR LOT |
| | LINE |
| | 29. PLEASE PROVIDE A SEPARATION WITH A LINE OR OTHER |
| | MEANS ON MASSING STUDY BETWEEN PHASE I AND PROPOSED |
| | CIELO PROJECT |
| | 30. PLEASE PROVIDE: |
| | A. BUILDING SECTIONS |
| | B. CONTEXTUAL ELEVATIONS |
| | C. GROUND FLOOR COLORED, CONTEXTUAL RENDERINGS WITH |
| | PLANTING HEIGHT LANDSCAPE |
| | D. MATERIAL SAMPLE IMAGERY AND MATERIAL SPECIFICATION |
| | DETAIL |
| | E. EXHIBITS OF SCORING LINE DEPTHS AND MATERIAL |
| | SECTIONS |
| | ENGINEERING |
| | 31. SUBMIT UPDATED CIVIL PLANS REFLECTING NEW PROPOSAL |
| | AND INDICATE WHAT WAS COMPLETED WITH PHASE I AND WHAT |
| | IS PROPOSED AS PART OF THIS APPLICATION AND UPDATE |
| | AERIAL IMAGERY TO CURRENT DAY |
| | 32. PLEASE SHOW DOUBLE STRIPING IN PARKING GARAGE AND |
| | INCLUDE PARKING LOT STRIPING DETAIL PER SECTION 94-485 |
| | 33. PLEASE SHOW OUTLINE OF BUILDINGS ON WEST SIDE OF |
| | DIXIE ON ALL PLANS |
| | 34. PLEASE PROVIDE UPDATED CROSS SECTIONS INCLUDING: |
| | A. SIDEWALK SECTIONS ADJACENT TO PARALLEL PARKING |
| | SPACES |
| | B. SIDEWALK SECTIONS ADJACENT TO RETAIL/COMMERCIAL DOOR |
| | ENTRANCES |
| | C. SIDEWALK SECTIONS ADJACENT TO RESIDENTIAL UNITS |
| | 35. ALL LARGE GRADING CHANGES SHALL BE CAPTURED WITHIN |
| | BUILDING NOT WITHIN SIDEWALK OR ROW |
| | 36. ILLUSTRATE INTERSECTION ADA RAMPS THAT MATCH THOSE |
| | ACROSS THE STREET ON ALL SIDES (SUBJECT TO REVIEW BY |
| | CITY TRANSPORTATION ENGINEER) |
| | 37. PLAN REFERENCES THE REMOVAL OF TRAFFIC CALMING ON |
| | 6TH STREET. IS THIS PROPOSED AS PART OF THIS |
| | APPLICATION? PLEASE CLARIFY WHY IF SO |
| | 38. A PEDESTRIAN ACCESS EASEMENT (ITEM NO. 10 ORB 28271 |
| | PAGE 144, ITEM H) EXISTS ON THE BOUNDARY SURVEY THAT |
| | CONNECTS THE ROW SIDEWALK TO THE GARAGE OF THE LOFTIN |
| | PHASE I STRUCTURE BUT THIS IS NOT INCORPORATED INTO THE |
| | PROPOSED DESIGN. PLEASE CLARIFY HOW ACCESS WILL REMAIN |
| | TO THIS PARKING GARAGE/UTILITY AREA |
| | 39. THE DECLARATION OF EASEMENTS (ORB 28271 PAGE 144) |
| | MAY HAVE TO BE UPDATED AND AMENDED AS NECESSARY SUBJECT |
| | TO CITY ENGINEERING AND CITY LEGAL REVIEW |
| | 40. PLEASE PROVIDE PHOTOMETRIC PLAN FOR ALL ROW |
| | INCLUDING PUBLIC OPEN SPACE, GARAGE ENTRANCES AND |
| | EXITS, ALL SIDEWALKS, ANY SIDEWALKS LEADING INTO |
| | BUILDING OR GARAGE AND INCLUDE LIGHT POLE SPECS |
| | 41. PLEASE INDICATE LOCATION OF ALL ABOVE GROUND, ROOF |
| | MOUNTED, UNDERGROUND AND WALL MOUNTED UTILITIES. PLEASE |
| | PLACE OUTSIDE ROW WITHIN SIDE INTERIOR LOT LINES (IF |
| | POSSIBLE PER UTILITY REQUIREMENTS) AND SCREEN TO BEST |
| | EXTENT POSSIBLE WITH LANDSCAPE OR STRUCTURAL |
| | ARCHITECTURALLY COMPATIBLE COVERING. SUBJECT TO REVIEW |
| | BY MARK HURLEY (FOR DOMESTIC BACKFLOW AND WATER |
| | METERS), RAY CARANCI FOR IRRIGATION METERS, TRACY WARD |
| | FOR STORMWATER DRAINAGE, AND ALL APPLICABLE DEPARTMENTS |
| | 42. PLEASE WALL MOUNT ALL FDC ? SUBJECT TO APPROVAL BY |
| | CHIEF PETER LEDUC |
| | LANDSCAPE: |
| | 43. PLEASE ENSURE PROPERTY LINE IS SHOWN IN CORRECT |
| | LOCATION (SEE COMMENT IN ARCHITECTURAL SECTION) |
| | 44. PLEASE EXTEND PLANTER BED ALONG AREAS ADJACENT TO |
| | PARALLEL PARKING WITH SMALL CUT THRU FOR PEDESTRIANS IN |
| | ACCESSIBLE LOCATIONS |
| | 45. PLEASE INDICATE WHICH TYPE OF PUBLIC OPEN SPACE, |
| | SEMI-PUBLIC OPEN SPACE AND PRIVATE OPEN SPACE IS BEING |
| | PROPOSED BASED ON THE PERMITTED TYPES IN THE ZONING |
| | DISTRICT (TABLE IV-6), AND MAKING SURE THAT THE |
| | SELECTED TYPES MEETS THE DEFINITION (SECTION 94-109) OF |
| | EACH SPECIFIC OPEN SPACE TYPE (GARDEN, TERRACE, GARDEN |
| | PLAZA, ETC.), AND THAT THE SPECIFIC REQUIREMENTS OF |
| | EACH OPEN SPACE TYPE (TABLE IV-7) ARE MET WITHIN THAT |
| | AREA. |
| | 46. THE PORTION OF LANDSCAPE BETWEEN THE PROPOSED |
| | PARKING GARAGE AND PROPERTY LINE WOULD NOT MEET ANY OF |
| | THE DEFINITIONS OF TYPES OF PRIVATE OPEN SPACE. CHECK |
| | PROPERTY LINE PLACEMENT HERE AS THE PHASE I PARKING |
| | GARAGE APPEARS ON PAPA TO BE RIGHT UP ON THE PROPERTY |
| | LINE |
| | 47. THE DOG PARK CANNOT BE DESIGNED AS A PRIVATE |
| | AMENITY AND BE COUNTED AS PUBLIC OPEN SPACE. IT WOULD |
| | HAVE TO BE OPEN TO THE GENERAL PUBLIC TO BE CONSIDERED |
| | A PUBLIC OPEN SPACE. SEE DEFINITION OF PUBLIC OPEN |
| | SPACE IN SECTION 94-109. THE TYPE OF OPEN SPACE |
| | UTILIZED MUST BE PERMITTED WITHIN THE DISTRICT (LD-4 OR |
| | LD-10) AND THE REQUIREMENTS ARE IN TABLE IV-7 FOR EACH |
| | TYPE OF OPEN SPACE. THIS AREA HAS THE ABILITY TO MEET |
| | SOME REQUIREMENTS FOR PUBLIC OPEN SPACE. THE TYPES CAN |
| | BE EITHER GARDEN COURTYARD OR GARDEN PLAZA |
| | 48. PLEASE ILLUSTRATE HOW THE PROPOSED PUBLIC OPEN |
| | SPACE AT THE SOUTH SIDE OF THE SOUTH BUILDING WILL |
| | CONNECT TO THE EXISTING AREA. PLEASE REMOVE THE |
| | PROPOSED BUTTONWOOD SHRUB TO CONNECT HE OPEN SPACES |
| | TOGETHER TO IMPROVE THE EXISTING OPEN SPACE AND PROVIDE |
| | FOR PEDESTRIAN CONNECTIVITY FOR THE PUBLIC AREAS. |
| | EXPLORE REMOVING THE FENCE ON THE LOFTIN PHASE I |
| | PROPERTY WITHIN THIS AREA TO BETTER CONNECT |
| | 49. PLEASE REDUCE THE AMOUNT OF HARDSCAPE WITHIN THE |
| | PASSAGE AREAS TO THE NORTH COURTYARD AND INCLUDE |
| | PLANTING AREAS |
| | 50. THE AREAS AROUND THE RESIDENTIAL UNITS CAN BE |
| | COUNTED AS SEMI-PUBLIC WALK UP GARDENS ONLY IN THE |
| | PORTIONS THAT MEET THE REQUIREMENT OF 7 FEET DEPTH. |
| | PLEASE ADD STAIRS FOR GROUND FLOOR ACCESS FROM THE |
| | STREET. THESE LANDSCAPE AREAS COULD BE COUNTED AS |
| | PRIVATE OPEN SPACE GARDEN TYPE IF A 4-FOOT WALL IS |
| | PLACED (TO MEET DEFINITION OF GARDEN IN SECTION 94-109) |
| | THE AREAS ADJACENT TO THE RETAIL/COMMERCIAL SPACES |
| | DON?T MEET THIS REQUIREMENT. |
| | 51. THE AREAS COUNTED AS SEMI-PUBLIC OPEN SPACE WHICH |
| | EXCEED THE PERCENTAGE OF REQUIRED SEMI PUBLIC COULD BE |
| | COUNTED TOWARDS THE PERCENTAGE OF REQUIRED PRIVATE OPEN |
| | SPACE, BUT HAVE TO BE TREATED AS A PERMITTED PUBLIC |
| | OPEN SPACE TYPE IN LD-10/LD-4 AND OPEN TO THE GENERAL |
| | PUBLIC |
| | 52. THE PORTION OF PUBLIC OPEN SPACE AT THE SOUTH SIDE |
| | OF THE NORTH BUILDING WOULD NOT BE MEET THE REQUIREMENT |
| | FOR MINIMUM SIZE, WHICH REQUIRES THAT NO ONE SIDE CAN |
| | BE 5 TIME THE LENGTH OF ANY OTHER SIDE AS THE LENGTH |
| | EXCEEDS THE DEPTH BY OVER 5X |
| | PROPOSED PROVISOS: |
| | 1. AN AMENDMENT TO HE RESTRICTIVE COVENANT MAY BE |
| | REQUIRED IF NECESSARY PENDING ENGINEERING AND LEGAL |
| | REVIEW |
| | 2. ALL ABOVE GROUND UTILITIES SHALL BE LOCATED WITHIN |
| | SIDE INTERIOR LOT LINES IF POSSIBLE AND SCREENED BY |
| | LANDSCAPE, HARDSCAPE OR ARCHITECTURALLY COMPATIBLE |
| | SCREENING. FIELD LOCATES SHALL BE SUBJECT TO ZONING |
| | APPROVAL |
| | 3. ALL PARKING GARAGE CEILINGS SHALL BE PAINTED |
| | (INCLUDING CEILING PIPES AND UTILITIES) TO A DEPTH OF |
| | 20 FEET FROM ENTRANCES/EXITS AND FROM ALL OPENINGS |
| | 4. APPLICANT SHALL ENTER MAINTENANCE AGREEMENT WITH |
| | CITY FOR ALL STREETSCAPE UPGRADES (TREES, TREE GRATES, |
| | BENCHES, LANDSCAPE, ETC) WITHIN THE CITY OWNED ROW TO |
| | INCLUDE BUS SHELTER |
| | 5. THE SIDEWALK SHALL BE KEPT LEVEL ACROSS CURB CUTS |
| | 6. A SIDEWALK EASEMENT WILL BE REQUIRED FOR PUBLIC |
| | SIDEWALK WITHIN PRIVATE PROPERTY |
| | |
| |
Print |