Plan Review Notes
Plan Review Notes For Project Z20120016
Project Number Z20120016
Review Stop TRAFFIC
Sequence Number 3
Notes
Date Text
2021-05-05 13:38:20TRAFFIC COMMENTS
 1) SATISFIED. PROVIDE COUNTY TPS LETTER
 2) SATISFIED. KEEP DRIVEWAY/WALKWAY LEVELED
 3) NOT SATISFIED. CONFIRM OR PROVIDE CAPACITY FOR
 PUBLIC TRANSIT VEHICLES STOPS AND POTENTIALLY
 ESTABLISHING A TRANSIT HUB WITHIN THE PROPOSED
 DEVELOPMENT.
 A. SHOWCASE THE PROPOSED RIDE SHARE AREA IN THE SITE
 PLAN
 B. SHOWCASE THE PROPOSED TRANSIT STOP(S) IN THE SITE
 PLAN
 C. PROVIDE A FIGURE SHOWCASING EXISTING TRANSIT
 STOPS/FACILITIES WITHIN HALF A MILE FROM THE SITE
 D. COORDINATE WITH PALM TRAN AND PROVIDE FEEDBACK
 PERTAINING FUTURE AND/OR POTENTIAL TRANSIT ROUTES ALONG
 QUADRILLE, OKEECHOBEE AND LAKEVIEW BLVD
 4) SATISFIED. CLARIFY THE DRIVEWAY FUNCTIONALITY ON THE
 WEST SIDE OF THE DEVELOPMENT ON QUADRILLE BLVD,
 SPECIFICALLY:
 A. ARE VALET OPERATIONS CONDUCTED THERE?
 B. IS IT FOR PICK-UP, DROP-OFF OR BOTH?
 C. IS IT ACCESSIBLE TO ALL VEHICLES OR JUST
 TAXI/UBER/LYFT?
 5) NOT SATISFIED. UNLESS MONITORING IS PROPOSED, THE
 PICK-UP/DROP OFF AREA ON QUADRILLE SHOULD NOT BE
 ACCESSIBLE TO ANY VEHICLE, EXCEPT FOR TRANSIT,
 EMERGENCY AND SECURITY OPERATORS.
 6) NOT SATISFIED. PROVIDE MORE DETAILS OF VALET
 OPERATIONS
 A. PROPOSED VALET DROP-OFF LOCATION IS NOT FEASIBLE, AS
 THERE IS NO QUEUE STORAGE LENGTH PROVIDED. TWO QUEUED
 VEHICLES WOULD BLOCK THE GARAGE ACCESS RAMP.
 B. HIGHLIGHT/SHOWCASE VEHICLES? PATH FROM THE SECOND
 FLOOR DROP-OFF LOCATION TO THE VALET SPOTS ON THE FIRST
 LEVEL
 7) NOT SATISFIED. FEC RAILROAD CROSSING UPGRADE:
 PROVIDE SIDEWALK CONNECTION ALONG OKEECHOBEE BLVD ON
 THE SOUTH SIDE. PROVIDE FDOT PERMIT OR FEEDBACK ON THE
 MATTER.
 8) SATISFIED. GARAGE ACCESS RAMP ON THE SOUTH SIDE
 SHOULD BE SET PERPENDICULAR TO OKEECHOBEE BLVD, IF BOTH
 INBOUND/OUTBOUND MOVEMENTS ARE CONTEMPLATED
 9) SATISFIED. CONSIDER ONE-WAY OPERATIONS AT DRIVEWAYS.
 FOR EXAMPLE: ENTRY ONLY IN THE SOUTH SIDE, EXIT ONLY ON
 THE NORTH SIDE
 10) SATISFIED. PROVIDE TWO MICRO-MOBILITY DESIGNATED
 AREAS NEARBY BUILDING ENTRANCES. WITH THE FOLLOWING
 CHARACTERISTICS:
 A. DIMENSIONS: 8 X 20 FEET
 B. CONDUIT (2 FEET SCHEDULE 40 PVC) TO A POWER SOURCE
 WITH AN ELECTRICAL PULL BOX (240V CIRCUIT)
 11) SATISFIED. COORDINATE WITH PARKING DEPARTMENT FOR
 PARKING LOSS COMPENSATION/MITIGATION
 12) NOT SATISFIED. PROVIDE AUTOTURN ANALYSIS FOR
 GARBAGE AND SERVICE VEHICLES.
 13) NOT SATISFIED. PROPOSED DRIVEWAYS? WIDTH IS
 EXCESSIVE AND UNSAFE. PROVIDE A MINIMUM OF 5 FEET WIDE
 PEDESTRIAN REFUGE ISLAND BETWEEN SERVICE DRIVE AND
 GARAGE ACCESS/ENTRY
 14) NOT SATISFIED. PROVIDE BICYCLE RACKS NEARBY
 BUILDING ENTRANCE(S) AND DISTINCTIVELY MARK THEM ON
 SITE PLANS
 15) NOT SATISFIED. UNLESS AUTOTURN ANALYSIS PROVES
 PARKING MANEUVERABILITY, REMOVE THE LAST TWO PARKING
 STALLS AT THE DEAD-END ON THE NINTH FLOOR OF THE
 GARAGE.
 16) PARTIALLY SATISFIED. COORDINATE WITH PLANNING
 DEPARTMENT FOR TDM MITIGATION MEASUREMENTS. A FINAL AND
 MUTUALLY AGREED LIST OF TDM MEASUREMENTS SHALL BE
 PROVIDED IN ORDER TO PASS THE TRAFFIC ENGINEERING
 REVIEW.
  
 VALERIO ORICCHIO
 CITY TRANSPORTATION ENGINEER
 561-494-1092
 [email protected]
  