| Date |
Text |
| 2021-06-03 12:27:14 | |
| | |
| | 1. PLEASE SEE COMMENTS IN ENGINEERING REGARDING WATER |
| | LINE UNDER UTILITY BOXES ? AGREEMENT SHALL BE REQUIRED |
| | (ACKNOWLEDGED) |
| | 2. PLEASE UPDATE PARKING NUMBERS TO REFLECT REMOVED |
| | SPACES. FOUR PARKING SPACES WERE REMOVED AS PART OF |
| | THIS GENERATOR WORK, NOT THREE (ONE SPACE ADJACENT TO |
| | BUILDING) (SATISFIED) |
| | 3. PLEASE CLARIFY, WHAT IS THE PURPOSE OF THE PROPOSED |
| | CURB ALONG THE ROW OF PARKING SPACES DIRECTLY SOUTH OF |
| | THE PROPOSED RAMP? WILL THIS CAUSE DRAINAGE ISSUES OR |
| | DIRECT STORMWATER INTO LANDSCAPE? (SATISFIED) |
| | 4. THERE ARE EXISTING BOLLARDS AND EQUIPMENT ALONG THE |
| | SOUTH SIDE OF THE GENERATOR ENCLOSURE THAT ARE NOT |
| | INDICATED ON THE LANDSCAPE PLAN. THE PROPOSED LANDSCAPE |
| | WOULD LIKELY INTERFERE WITH THE EXISTING EQUIPMENT. |
| | PLEASE CONFIRM (SATISFIED) |
| | 5. PLEASE INCLUDE LANDSCAPE WITHIN THE SOUTH TERMINAL |
| | ISLAND OF THE ROW OF PARKING SPACES THAT ARE EAST OF |
| | THE GENERATOR ENCLOSURE (SATISFIED) |
| | 6. APPEARS TO BE SOME CONFLICT BETWEEN PROPOSED |
| | LANDSCAPE AND EXISTING UTILITIES NORTH OF THE DUMPSTER |
| | ENCLOSURE (SATISFIED) |
| | 7. PLEASE ADD PROPOSED LANDSCAPE TO A FULL LANDSCAPE |
| | PLAN THAT INCLUDES ALL PREVIOUS WORK ? PREVIOUS |
| | LANDSCAPE PLANS CAN BE REQUESTED FROM CITY STAFF. |
| | (ACKNOWLEDGED) |
| | 8. THE NEW ALIGNMENT OF THE CENTRAL ROW OF PARKING |
| | SPACES DOES NOT WORK FOR BI-DIRECTIONAL MOVEMENT ALONG |
| | THE EAST, AS A MINIMUM OF 24 FEET OF DRIVE AISLE IS |
| | REQUIRED. PLEASE SEE FIGURE XV-2 IN SECTION 94-485. THE |
| | WIDTH OF THE ONE DIRECTIONAL DRIVE AISLE COULD BE |
| | REDUCED TO 12? TO ACCOMMODATE THE NEEDED 24? WITHIN THE |
| | OTHER DRIVE AISLE. PLEASE EXAMINE FOR OTHER |
| | SOLUTIONS. (SATISFIED) |
| | 9. ARE THE CURB STOPS BEING REPLACE WITHIN PARKING |
| | SPACES? THEY ARE CURRENTLY STACKED ON THE GREEN AREA. |
| | PLEASE ADD TO PLAN WHERE NECESSARY.(SATISFIED) |
| | 10. PLEASE INDICATE WHICH PORTIONS OF THE PARKING LOT |
| | IS BEING RESURFACED. ANY AREAS THAT ARE RESURFACED |
| | SHALL BE BROUGHT TO CODE STANDARDS IN TERMS OF STRIPING |
| | (DOUBLE STRIPING REQUIRED) (SATISFIED) |
| | 11. PLEASE UPDATE THE LISTED NUMBER OF PARKING SPACES |
| | AT SECTION NEAR GENERATOR ENCLOSURE (NO LONGER 30 |
| | SPACES ? 4 WERE REMOVED) (SATISFIED) |
| | 12. UNDERSTANDING THIS IS AN EXISTING CONDITION, CAN |
| | ANY ADDITIONAL LANDSCAPE SCREENING AND/OR A WRAP BE |
| | ADDED TO THE ELECTRICAL BOX ALONG THE SIDEWALK ON OLIVE |
| | AVENUE? THIS COULD BETTER ENHANCE THE STREET FRONTAGE |
| | ALONG THIS SIDE. (SATISFIED) |
| | 13. PLEASE UPDATE LABELS THAT READ ?RELOCATE AND |
| | REPLACE EXISTING FIRE HYDRANT WITH NEW? AND OTHERS THAT |
| | APPLIED TO A PREVIOUS AMENDMENT FOR CLARIFICATION. |
| | (SATISFIED) |
| | |
| | COMMENTS FROM LIZ LEVESQUE, URBAN DESIGN PLANNER |
| | 561 822 1426 |
| | [email protected] |
| | |
| |