Plan Review Notes
Plan Review Notes For Project Z20080008
Project Number Z20080008
Review Stop SURVEY
Sequence Number 2
Notes
Date Text
2020-11-05 10:35:521. DUE TO PROXIMITY TO PROPOSED TREES, WATER MAIN ALONG
 CLEARWATER WILL ALSO NEED TO BE RELOCATED.
 2. SANITARY SEWER LINE RUNNING WEST FROM CLEARWATER
 WILL BE A PRIVATE LINE TO BE MAINTAINED BY THE MASTER
 ASSOCIATION. CITY POINT OF SERVICE WILL BE PROPOSED MH
 #2.
 3. THE METER/BACKFLOWS/IRRIGATION ASSEMBLIES IN THE SE
 CORNER NEEDS TO BE RE-WORKED. IT DOES NOT APPEAR THERE
 IS ROOM ENOUGH BETWEEN THE EXISTING CONCRETE
 POLE/ANCHORS AND THE BUILDING TO SERVICE THE METER.
 4. AS THE SURVEY INCLUDES THE OVERALL PROPERTY, THE
 MASTER ASSOC. NEEDS TO BE A CO-APPLICANT.
  
  
 FOLLOWING ARE COMMENTS FROM LAURA LE, PUBLIC UTILITIES
 ENGINEER
  
 1. NEED TO SHOW EXIST LATERALS AND EXIST WATER
 SERVICES, IF ANY; THE MOST OF THE LATERALS HAVE
 RECENTLY BEEN LINED
 2. DID THEY TV THE SAN SEWER RECENTLY? DOES PIPE SIZE
 MATCH SURVEYED INFO?
 3. EXIST SAN MH NEED TO BE REHABBED. NOT SURE IF THAT
 WAS DONE RECENTLY.
 4. NEED A PROFILE OF THE NEW SAN SEWER
 5. THE SAN SEWER REDUCED BACK TO 8? JUST UPSTREAM OF
 THE LIFT STATION. WE WILL NEED TO LOOK AT THE PIPE
 DOWNSTREAM OF THE PROJECT.
 WE WILL ALSO CHECK THE PUMPS AT THE LIFT STATION
 6. IS THERE AN EASEMENT FOR THE EXIST 8? COMING FROM
 AUSTRALIAN AVE? IS IT CITY?S OWNED AND MAINTAINED?
  