| Plan Review Notes For Project Z20070009 |
| Project Number |
Z20070009 |
|
| Review Stop |
TRAFFIC |
| Sequence Number |
4 |
|
| Notes |
| Date |
Text |
| 2021-03-23 20:33:46 | TRAFFIC COMMENTS: | | | 1) PROVIDE A CROSSWALK ON THE SOUTH-EAST SIDE OF THE | | | PROPERTY ACROSS THE SOUTH ACCESS ROAD | | | 2) PROVIDE A CROSSWALK ON THE NORTH SIDE OF THE | | | PROPERTY BETWEEN THE CONNECTION TO PUBLIC ROW AND | | | PROPOSED 2-STORY OFFICE BUILDING ENTRANCE | | | 3) PROVIDE A CROSSWALK ON THE NORTH SIDE OF THE | | | PROPERTY ACROSS WEKIVA WAY | | | 4) INSTALL OR REPLACE ADA TACTILE MATS WHERE MISSING OR | | | NEEDED. IDENTIFY SUCH FEATURE ON EITHER THE SITE OR | | | CIVIL PLANS | | | | | | SITE COMMENTS: | | | 5) SHOW SOUTH ACCESS ROAD WIDTH DIMENSIONS | | | 5A. CURB TO CURB | | | 5B. TRAVEL LANE(S) | | | 6) SHOW PARKING STALLS' DIMENSIONS ALONG THE SOUTH | | | ACCESS ROAD | | | 7) PROVIDE COLORED AUTOTURN ANALYSIS, SO TO PROPERLY | | | DIFFERENTIATE BETWEEN ROAD/BUILDING LINES AND VEHICLE'S | | | DYNAMIC ENVELOPE | | | 8) PROVIDE SEPARATE AUTOTURN ANALYSIS OUTPUT FOR EACH | | | VEHICLE PATH. CURRENT ANALYSIS IS NOT EASILY READABLE | | | DUE TO MULTIPLE PATH OVERLAPS. | | | 9) GARBAGE-TRUCK AUTOTURN ANALYSIS SHOWS SEVERAL | | | VEHICLE ENCROACHMENTS' INSTANCES: | | | 9A. SOUTH ENTRANCE BULB-OUT | | | 9B. PARKING STALLS ON THE NORTH SIDE OF THE SOUTHERN | | | ACCESS ROAD | | | | | | VALERIO ORICCHIO | | | CITY TRANSPORTATION ENGINEER | | | 561-494-1092 | | | [email protected] | | | |
| |
Print |
|