2020-08-12 15:38:38FROM: RAY CARANCI, SENIOR LANDSCAPE PLANNER
 561-822-1462
 PROJECT: HULETT CPD Z20070009
 AUGUST 12, 2020
 I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND
 PROVIDE THE FOLLOWING COMMENTS:
  
 1. PROVIDE THE FOLLOWING CORRECTIONS TO TREE
 DISPOSITION CHART SHEET L2:
 ? PROVIDE THE CANOPY DIAMETERS FOR ALL TREES.
 ? IF CANOPY DIAMETERS ARE 20 FEET OR MORE, CALCULATE
 THE ACTUAL SQUARE FOOTAGE AND ENTER INTO THE MITIGATION
 DUE COLUMN IF PROPOSED FOR REMOVAL. IF UNDER 20 FEET,
 THE SQUARE FOOTAGE IS BASED ON THE CATEGORY FOR THE
 TREE. ADD A COLUMN FOR THE CANOPY SQUARE FOOTAGE FOR
 ALL TREES AND PALMS.
 ? ADD A COLUMN AND LIST THE CATEGORY FOR EACH TREE AND
 PALM FROM THE CITY REFERENCE LIST.
 ? REMOVE EXISTING ?UNIDENTIFIED TREE TO BE REMOVED?
 FROM THE TREE ACTION LEGEND LIST, AS ALL TREES MUST BE
 PROPERLY IDENTIFIED.
 ? REMOVE NOTE REFERENCING DBH.
 ? ASSIGN NUMBERS AND INCLUDE TREE AND 5 PALMS SHOWN IN
 RED ALONG THE SOUTH PROPERTY LINE.
 ? CHANGE TREE CREDITS COLUMN TO MITIGATION DUE, AND
 LIST SQUARE FOOTAGE IF MITIGATION IS DUE.
 ? PROVIDE THE TOTAL SQUARE FOOTAGE OF MITIGATION DUE
 AND SHOW MITIGATION SQUARE FOOTAGE PROVIDED FROM THE
 PROPOSED TREE LIST AFTER ALL CORRECTIONS.
 ? INCLUDE A LIST OF ALL SPECIES AND QUANTITIES COUNTED
 TOWARD MITIGATION BASED ON THE LANDSCAPE PLAN, NOT
 INCLUDING REPLACEMENTS FOR MISSING APPROVED TREES AND
 PALMS.
  
 2. SECTION 94-448 (D)(3) REQUIRES NATIVE TREES IN GOOD
 CONDITION TO BE PRESERVED ON SITE OR RELOCATED. ANSI A
 300 (PART 5) STANDARDS SPECIFY EXAMPLES OF SUITABILITY
 RATINGS OF GOOD, MODERATE, OR POOR FOR RELOCATION.
 PROVIDE CONDITION FOR ALL EXISTING TREES AND PALMS AND
 RELOCATION POTENTIAL FOR THE NATIVE TREES AND PALMS
 BASED ON A CERTIFIED ARBORISTS REPORT.
  
 3. EXPLAIN THE DIFFERENCE IN PERVIOUS AREA AND
 LANDSCAPE AREA SQUARE FOOTAGE.
  
 4. REMOVE ?S. DIXIE HWY.? FROM WEST PROPERTY LINE
 BUFFER REFERENCE.
  
 5. PROVIDE THE FOUNDATION PLANTING CALCULATION REQUIRED
 AND PROVIDED FOR EACH BUILDING.
  
 6. THE APPROVED LANDSCAPE PLAN FROM RES. NO. 266-12
 EXHIBIT D IS THE APPROVED PLAN OF RECORD, AND THIS IS
 AN AMENDMENT TO THAT PLAN. ALL AREAS THAT ARE NOT BEING
 ALTERED WITH THIS AMENDMENT NEED TO SHOW THE PREVIOUSLY
 APPROVED LANDSCAPING. THERE ARE NUMEROUS TREES AND
 PALMS MISSING FROM THE EXISTING SITE AND MUST BE
 REPLACED UNLESS THE AREA IS BEING ALTERED.
  
  
 7. PROVIDE THE NUMBER AND PERCENTAGE OF SUBSTITUTION OF
 PALMS FOR REQUIRED TREES. SECTION 94-442(D) REQUIRES A
 3:1 RATIO FOR SUBSTITUTION FOR PALMS EXCEPT THE LISTED
 1:1 SPECIES.
  
 8. PROVIDE A PLAN SHOWING THE PARKING LANDSCAPE AREAS
 COUNTED TOWARD COMPLIANCE WITH SECTION 94-443(C)(3) AND
 (4) AND PROVIDE CALCULATIONS. PROVIDE THE TOTAL
 REQUIRED AND PROVIDED AS ONE TOTAL FOR BOTH SECTIONS. A
 SEPARATE EXHIBIT MAY BE PROVIDED TO DEMONSTRATE THE
 AREAS COUNTED.
  
 9. SECTION 94-443 (C)(3)A. REQUIRES A TERMINAL
 LANDSCAPE ISLAND AND REQUIRED TREE FOR EACH ROW OF
 PARKING. (3)B. REQUIRES AN INTERIOR LANDSCAPE ISLAND
 WITH A REQUIRED TREE SO THERE ARE NO MORE THAN 10
 SPACES IN A ROW. ALL THESE LANDSCAPE AREAS MUST MEET
 THE MINIMUM WIDTH OF 8 FEET OF LANDSCAPE AREA AND BE
 THE FULL LENGTH OF THE ADJACENT SPACE. ALL
 RECONSTRUCTED AREAS OF PARKING MUST MEET THESE
 REQUIREMENTS, AND THE APPROVED PLAN FOLLOWED FOR
 UNALTERED AREAS.
  
 10. SECTION 94-443(C)(3) REQUIRES THAT A MINIMUM OF 75
 PERCENT OF ALL TREES THAT ARE REQUIRED TO BE PLANTED
 WITHIN THE INTERIOR OF AN OFF STREET PARKING AREA SHALL
 BE CATEGORY 1 SHADE TREES. SHOW THE PERCENTAGE OF
 CATEGORY 1 TREES PROVIDED FOR THE REQUIRED LANDSCAPE
 AREAS AS REQUIRED BY SECTION 94-443(C)(3) FOR DIVIDER
 ISLANDS, TERMINAL, AND INTERIOR ISLANDS.
  
 11. IN THE PARKING AREAS BEING RECONSTRUCTED, STAFF
 SUGGESTS REDUCING THE PAVED AREAS FOR PARKING SPACES
 AND USING CURBS INSTEAD OF WHEEL STOPS TO ALLOW FOR
 PERVIOUS LANDSCAPE AREA AT THE OVERHANG. THIS ALSO
 ALLOWS MORE LANDSCAPE AREA FOR SUPPORTING THE ROOT
 ZONES OF THE TREES.
 12. ADD A COLUMN TO THE PLANT LIST FOR DROUGHT TOLERANT
 LEVELS OF EACH SPECIES AND WHETHER FLORIDA NATIVE.
  
 13. REVISE THE SECTION IN THE LANDSCAPE DATA CHART TO
 COMPLY WITH SECTION 94-445 L. PLANT SPECIES. A MINIMUM
 OF 60 PERCENT OF PLANT MATERIAL ADDED SHALL BE FLORIDA
 NATIVE OR DROUGHT TOLERANT SPECIES SELECTED FROM THE
 CITY LIST OR THE LIST OF SPECIES IN THE MOST RECENT
 EDITION OF SOUTH FLORIDA WATER MANAGEMENT DISTRICT
 WATERWISE SOUTH FLORIDA LANDSCAPES.
 PROVIDE THE TOTAL PERCENTAGE OF NATIVE AND DROUGHT
 TOLERANT PLANTS BASED ON FINAL PLANT LIST.
  
 14. SHOW LOCATIONS OF FPL TRANSFORMERS ON THE LANDSCAPE
 PLAN AND RESOLVE CONFLICTS WITH LANDSCAPING.
  
 15. THERE ARE MULTIPLE CONFLICTS BETWEEN REQUIRED TREES
 AND THE PROPOSED WATER LINES, HYDRANTS AND BACKFLOW
 PREVENTERS ON THE PRELIMINARY ENGINEERING PLANS. THESE
 WILL CONFLICT WITH REQUIRED TREES IN THE LANDSCAPE
 AREAS. ALL CHANGES PROPOSED TO PALM BEACH COUNTY WATER
 UTILITY LOCATIONS MUST BE FIRST REVIEWED AND APPROVED
 BY THE CITY TO VERIFY THERE WILL NOT BE CHANGES TO THE
 LANDSCAPE OR SITE PLAN THAT WILL CREATE
 NONCONFORMITIES.
  
 16. PROVIDE SCREENING FOR ALL GROUND MOUNTED VALVES AND
 EQUIPMENT.
  
 17. INDICATE HOW LAKE WORTH DRAINAGE DISTRICT WILL
 ACCESS AREAS OF THE CANAL FOR MAINTENANCE. IF THE
 PREVIOUS GAPS IN THE SOUTH BUFFER ARE NO LONGER
 REQUIRED FOR ACCESS, THE REQUIRED PLANTINGS ARE TO BE
 RESTORED. PROVIDE DISTRICT APPROVAL OF ALL LANDSCAPING
 PROPOSED WITHIN THEIR EASEMENT.
 CONDITIONS OF APPROVAL
 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON
 THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE
 SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT
 SERVICES DEPARTMENT, PLANNING DIVISION.
  