| Date |
Text |
| 2020-08-12 15:38:38 | FROM: RAY CARANCI, SENIOR LANDSCAPE PLANNER |
| | 561-822-1462 |
| | PROJECT: HULETT CPD Z20070009 |
| | AUGUST 12, 2020 |
| | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND |
| | PROVIDE THE FOLLOWING COMMENTS: |
| | |
| | 1. PROVIDE THE FOLLOWING CORRECTIONS TO TREE |
| | DISPOSITION CHART SHEET L2: |
| | ? PROVIDE THE CANOPY DIAMETERS FOR ALL TREES. |
| | ? IF CANOPY DIAMETERS ARE 20 FEET OR MORE, CALCULATE |
| | THE ACTUAL SQUARE FOOTAGE AND ENTER INTO THE MITIGATION |
| | DUE COLUMN IF PROPOSED FOR REMOVAL. IF UNDER 20 FEET, |
| | THE SQUARE FOOTAGE IS BASED ON THE CATEGORY FOR THE |
| | TREE. ADD A COLUMN FOR THE CANOPY SQUARE FOOTAGE FOR |
| | ALL TREES AND PALMS. |
| | ? ADD A COLUMN AND LIST THE CATEGORY FOR EACH TREE AND |
| | PALM FROM THE CITY REFERENCE LIST. |
| | ? REMOVE EXISTING ?UNIDENTIFIED TREE TO BE REMOVED? |
| | FROM THE TREE ACTION LEGEND LIST, AS ALL TREES MUST BE |
| | PROPERLY IDENTIFIED. |
| | ? REMOVE NOTE REFERENCING DBH. |
| | ? ASSIGN NUMBERS AND INCLUDE TREE AND 5 PALMS SHOWN IN |
| | RED ALONG THE SOUTH PROPERTY LINE. |
| | ? CHANGE TREE CREDITS COLUMN TO MITIGATION DUE, AND |
| | LIST SQUARE FOOTAGE IF MITIGATION IS DUE. |
| | ? PROVIDE THE TOTAL SQUARE FOOTAGE OF MITIGATION DUE |
| | AND SHOW MITIGATION SQUARE FOOTAGE PROVIDED FROM THE |
| | PROPOSED TREE LIST AFTER ALL CORRECTIONS. |
| | ? INCLUDE A LIST OF ALL SPECIES AND QUANTITIES COUNTED |
| | TOWARD MITIGATION BASED ON THE LANDSCAPE PLAN, NOT |
| | INCLUDING REPLACEMENTS FOR MISSING APPROVED TREES AND |
| | PALMS. |
| | |
| | 2. SECTION 94-448 (D)(3) REQUIRES NATIVE TREES IN GOOD |
| | CONDITION TO BE PRESERVED ON SITE OR RELOCATED. ANSI A |
| | 300 (PART 5) STANDARDS SPECIFY EXAMPLES OF SUITABILITY |
| | RATINGS OF GOOD, MODERATE, OR POOR FOR RELOCATION. |
| | PROVIDE CONDITION FOR ALL EXISTING TREES AND PALMS AND |
| | RELOCATION POTENTIAL FOR THE NATIVE TREES AND PALMS |
| | BASED ON A CERTIFIED ARBORISTS REPORT. |
| | |
| | 3. EXPLAIN THE DIFFERENCE IN PERVIOUS AREA AND |
| | LANDSCAPE AREA SQUARE FOOTAGE. |
| | |
| | 4. REMOVE ?S. DIXIE HWY.? FROM WEST PROPERTY LINE |
| | BUFFER REFERENCE. |
| | |
| | 5. PROVIDE THE FOUNDATION PLANTING CALCULATION REQUIRED |
| | AND PROVIDED FOR EACH BUILDING. |
| | |
| | 6. THE APPROVED LANDSCAPE PLAN FROM RES. NO. 266-12 |
| | EXHIBIT D IS THE APPROVED PLAN OF RECORD, AND THIS IS |
| | AN AMENDMENT TO THAT PLAN. ALL AREAS THAT ARE NOT BEING |
| | ALTERED WITH THIS AMENDMENT NEED TO SHOW THE PREVIOUSLY |
| | APPROVED LANDSCAPING. THERE ARE NUMEROUS TREES AND |
| | PALMS MISSING FROM THE EXISTING SITE AND MUST BE |
| | REPLACED UNLESS THE AREA IS BEING ALTERED. |
| | |
| | |
| | 7. PROVIDE THE NUMBER AND PERCENTAGE OF SUBSTITUTION OF |
| | PALMS FOR REQUIRED TREES. SECTION 94-442(D) REQUIRES A |
| | 3:1 RATIO FOR SUBSTITUTION FOR PALMS EXCEPT THE LISTED |
| | 1:1 SPECIES. |
| | |
| | 8. PROVIDE A PLAN SHOWING THE PARKING LANDSCAPE AREAS |
| | COUNTED TOWARD COMPLIANCE WITH SECTION 94-443(C)(3) AND |
| | (4) AND PROVIDE CALCULATIONS. PROVIDE THE TOTAL |
| | REQUIRED AND PROVIDED AS ONE TOTAL FOR BOTH SECTIONS. A |
| | SEPARATE EXHIBIT MAY BE PROVIDED TO DEMONSTRATE THE |
| | AREAS COUNTED. |
| | |
| | 9. SECTION 94-443 (C)(3)A. REQUIRES A TERMINAL |
| | LANDSCAPE ISLAND AND REQUIRED TREE FOR EACH ROW OF |
| | PARKING. (3)B. REQUIRES AN INTERIOR LANDSCAPE ISLAND |
| | WITH A REQUIRED TREE SO THERE ARE NO MORE THAN 10 |
| | SPACES IN A ROW. ALL THESE LANDSCAPE AREAS MUST MEET |
| | THE MINIMUM WIDTH OF 8 FEET OF LANDSCAPE AREA AND BE |
| | THE FULL LENGTH OF THE ADJACENT SPACE. ALL |
| | RECONSTRUCTED AREAS OF PARKING MUST MEET THESE |
| | REQUIREMENTS, AND THE APPROVED PLAN FOLLOWED FOR |
| | UNALTERED AREAS. |
| | |
| | 10. SECTION 94-443(C)(3) REQUIRES THAT A MINIMUM OF 75 |
| | PERCENT OF ALL TREES THAT ARE REQUIRED TO BE PLANTED |
| | WITHIN THE INTERIOR OF AN OFF STREET PARKING AREA SHALL |
| | BE CATEGORY 1 SHADE TREES. SHOW THE PERCENTAGE OF |
| | CATEGORY 1 TREES PROVIDED FOR THE REQUIRED LANDSCAPE |
| | AREAS AS REQUIRED BY SECTION 94-443(C)(3) FOR DIVIDER |
| | ISLANDS, TERMINAL, AND INTERIOR ISLANDS. |
| | |
| | 11. IN THE PARKING AREAS BEING RECONSTRUCTED, STAFF |
| | SUGGESTS REDUCING THE PAVED AREAS FOR PARKING SPACES |
| | AND USING CURBS INSTEAD OF WHEEL STOPS TO ALLOW FOR |
| | PERVIOUS LANDSCAPE AREA AT THE OVERHANG. THIS ALSO |
| | ALLOWS MORE LANDSCAPE AREA FOR SUPPORTING THE ROOT |
| | ZONES OF THE TREES. |
| | 12. ADD A COLUMN TO THE PLANT LIST FOR DROUGHT TOLERANT |
| | LEVELS OF EACH SPECIES AND WHETHER FLORIDA NATIVE. |
| | |
| | 13. REVISE THE SECTION IN THE LANDSCAPE DATA CHART TO |
| | COMPLY WITH SECTION 94-445 L. PLANT SPECIES. A MINIMUM |
| | OF 60 PERCENT OF PLANT MATERIAL ADDED SHALL BE FLORIDA |
| | NATIVE OR DROUGHT TOLERANT SPECIES SELECTED FROM THE |
| | CITY LIST OR THE LIST OF SPECIES IN THE MOST RECENT |
| | EDITION OF SOUTH FLORIDA WATER MANAGEMENT DISTRICT |
| | WATERWISE SOUTH FLORIDA LANDSCAPES. |
| | PROVIDE THE TOTAL PERCENTAGE OF NATIVE AND DROUGHT |
| | TOLERANT PLANTS BASED ON FINAL PLANT LIST. |
| | |
| | 14. SHOW LOCATIONS OF FPL TRANSFORMERS ON THE LANDSCAPE |
| | PLAN AND RESOLVE CONFLICTS WITH LANDSCAPING. |
| | |
| | 15. THERE ARE MULTIPLE CONFLICTS BETWEEN REQUIRED TREES |
| | AND THE PROPOSED WATER LINES, HYDRANTS AND BACKFLOW |
| | PREVENTERS ON THE PRELIMINARY ENGINEERING PLANS. THESE |
| | WILL CONFLICT WITH REQUIRED TREES IN THE LANDSCAPE |
| | AREAS. ALL CHANGES PROPOSED TO PALM BEACH COUNTY WATER |
| | UTILITY LOCATIONS MUST BE FIRST REVIEWED AND APPROVED |
| | BY THE CITY TO VERIFY THERE WILL NOT BE CHANGES TO THE |
| | LANDSCAPE OR SITE PLAN THAT WILL CREATE |
| | NONCONFORMITIES. |
| | |
| | 16. PROVIDE SCREENING FOR ALL GROUND MOUNTED VALVES AND |
| | EQUIPMENT. |
| | |
| | 17. INDICATE HOW LAKE WORTH DRAINAGE DISTRICT WILL |
| | ACCESS AREAS OF THE CANAL FOR MAINTENANCE. IF THE |
| | PREVIOUS GAPS IN THE SOUTH BUFFER ARE NO LONGER |
| | REQUIRED FOR ACCESS, THE REQUIRED PLANTINGS ARE TO BE |
| | RESTORED. PROVIDE DISTRICT APPROVAL OF ALL LANDSCAPING |
| | PROPOSED WITHIN THEIR EASEMENT. |
| | CONDITIONS OF APPROVAL |
| | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON |
| | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE |
| | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT |
| | SERVICES DEPARTMENT, PLANNING DIVISION. |
| | |
| |
Print |