| 2020-07-23 13:29:14 | DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION, |
| | COMMENTS: |
| | |
| | 1. THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE |
| | SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH |
| | FLORIDA BUILDING CODE. THE FOLLOWING COMMENTS ARE TO BE |
| | ADDRESSED FOR THE BUILDING PERMIT APPLICATION. |
| | |
| | 2. EGRESS FROM THE BLEACHERS. SITE PLAN, SHEET C-1, |
| | SHOWS ONLY ONE 5'-0" PATH FOR EGRESS FROM THE |
| | BLEACHERS. THE PROPOSAL IS TO INCREASE THE TOTAL NUMBER |
| | OF OCCUPANTS FROM 534 SEATS TO 1324 SEATS. AT LEAST ONE |
| | ADDITIONAL EGRESS PATH IS REQUIRED PER SECTION 1029 OF |
| | FLORIDA BUILDING CODE. THE FOLLOWING COMMENTS ARE BASED |
| | ON REVIEW OF FIRE SAFETY PLAN, FS-1 |
| | - THE GREEN ROUTE SHOWS PEOPLE GETTING OFF THE |
| | BLEACHERS, GOING SOUTH ALONGSIDE THE BLEACHERS, AROUND |
| | THE END OF THE BLEACHERS AND THEN BACK NORTH ALONGSIDE |
| | THE SAME BLEACHERS. IF THE PROBLEM IS AT THE BLEACHERS, |
| | THAT ROUTE DOES NOT TAKE PEOPLE DIRECTLY AWAY FROM THE |
| | BLEACHERS. |
| | - THE RED ROUTE GOES THROUGH A GATE WHICH SWINGS THE |
| | WRONG WAY, WOULD NOT HAVE APPROPRIATE EGRESS HARDWARE |
| | FOR AN ASSEMBLY OCCUPANCY TYPE, AND LEADS ONTO THE |
| | PLAYING FIELD WHICH IS NOT WHEELCHAIR ACCESSIBLE. |
| | |
| | 3. SEPARATE PERMITS REQUIRED. ALL APPLICABLE PERMITS |
| | AND SUB-PERMITS MUST BE OBTAINED BEFORE COMMENCING THE |
| | WORK. SEPARATE PERMITS, PLANS AND FEES, ARE REQUIRED |
| | FOR SIGNS, SWIMMING POOLS AND SPAS, GAS SYSTEMS, |
| | GENERATORS, FIRE ALARM SYSTEMS, FIRE SPRINKLER AND |
| | OTHER FIRE SUPPRESSION SYSTEMS, GREASE INTERCEPTORS, |
| | SITE LIGHTING, SITE LANDSCAPE, SITE IRRIGATION, ETC. |
| | |
| | ROBERT BROWN |
| | BUILDING OFFICIAL |
| | TEL: 561 805 6652 |
| | EMAIL: [email protected] |
| | |
| | |
| | |
| |