| Date |
Text |
| 2021-05-08 23:20:22 | THIS IS A CONCEPTUAL LEVEL REVIEW. CONSTRUCTION LEVEL |
| | DETAILS, DESIGN CALCULATIONS AND THE POLLUTION |
| | PREVENTION PLAN WILL BE REVIEWED AS PART OF THE |
| | ENGINEERING DEVELOPMENT APPROVAL AND BUILDING PERMIT |
| | APPLICATION PROCESSES. |
| | |
| | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO SITE |
| | PLAN APPROVAL: |
| | |
| | 1. CONSTRUCTION EASEMENT AND APPROVAL OF SWALE MAY BE |
| | NEEDED FOR SWALE CONSTRUCTION WEST OF THE WEST PROPERTY |
| | LINE AS DEPICTED ON TYPICAL SECTION B-B. |
| | |
| | 2. WHERE DOES THE SWALE DEPICTED IN SECTION B-B DRAIN |
| | TO? |
| | |
| | 3. WILL SOUTH DRIVEWAY PREVENT POSITIVE DRAINAGE OF THE |
| | SWALE NORTH OF THE DRIVEWAY FROM REACHING THE EXISTING |
| | STORM INLET? |
| | |
| | 4. THE WEST MITERED END SECTION OF THE PROPOSED NORTH |
| | DRIVEWAY CULVERT APPEARS TO BE IN CONFLICT WITH THE |
| | CART/PEDESTRIAN SIDEWALK. THE MES? ARE DRAWN BACKWARDS. |
| | |
| | 5. PROVIDE CROSS SECTIONS OF EACH DRIVEWAY FROM EDGE OF |
| | ROAD PAVEMENT TO 5 FEET BEYOND THE HIGHPOINT OF THE |
| | DRIVEWAY OUTSIDE THE RIGHT OF WAY. |
| | |
| | 6. WILL THE CONCRETE SIDEWALKS CONTINUE THROUGH THE |
| | DRIVEWAYS? |
| | |
| | 7. OBTAIN APPROVAL FROM ENTITY RESPONSIBLE FOR THE ROAD |
| | RIGHT OF WAY AND DRAINAGE SYSTEM TO INSTALL DRAINAGE |
| | STRUCTURES IN THE RIGHT OF WAY AND CONNECT TO THE ROAD |
| | DRAINAGE SYSTEM. |
| | |
| | 8. IDENTIFY WHO WILL BE RESPONSIBLE TO MAINTAIN THE |
| | PROPOSED DRAINAGE STRUCTURE AND PIPES IN THE ROAD RIGHT |
| | OF WAY. THIS INCLUDES THE PROPOSED DRIVEWAY CULVERT AND |
| | THE PIPE CONNECTION TO THE EXISTING STORM INLET. |
| | |
| | 9. INDICATE IF A PERIMETER BERM WILL BE REQUIRED TO |
| | CONTAIN STORMWATER RUNOFF UP TO THE 25-YEAR 3-DAY STORM |
| | EVENT. |
| | |
| | |
| | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO |
| | ISSUANCE OF CONSTRUCTION AUTHORIZATION INCLUDING |
| | BUILDING PERMITS AND ENGINEERING DEVELOPMENT APPROVAL. |
| | |
| | 1. AN ENGINEERING DEVELOPMENT APPROVAL APPLICATION MAY |
| | BE REQUIRED FROM THE ENGINEERING SERVICES DEPARTMENT. |
| | |
| | 2. PROVIDE A COPY OF THE SFWMD ERP MODIFICATION WITH |
| | THE ENGINEERING PERMIT APPLICATION. |
| | |
| | 3. EROSION CONTROL PLAN AND DETAILS TO BE SUBMITTED |
| | WITH THE ENGINEERING PERMIT APPLICATION. |
| | |
| | 4. DRAINAGE CALCULATIONS WILL BE REVIEWED WITH THE |
| | ENGINEERING PERMIT APPLICATION. |
| | |
| | TRACY WARD, PE |
| | SENIOR STORMWATER ENGINEER |
| | ENGINEERING SERVICES DEPARTMENT |
| | 561-494-1120 (O) |
| | 561-351-0510 (M) |
| | [email protected] |
| | |
| |