| 2020-12-02 15:39:47 | FROM: RAY CARANCI, SENIOR LANDSCAPE PLANNER |
| | 561-822-1462 |
| | PROJECT: PRIME DEVELOPMENT CPD AND WAWA Z20040014 |
| | DECEMBER 2, 2020 |
| | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND |
| | PROVIDE THE FOLLOWING COMMENTS: |
| | |
| | 1. THE SURVEY, SITE PLAN AND LANDSCAPE PLAN SHOW |
| | INCONSISTENCIES WITH THE OVERALL LANDSCAPE REQUIREMENTS |
| | . THESE NEED TO BE CORRECTED TO DO AN ACCURATE AND |
| | COMPLETE LANDSCAPE REVIEW. SITE CALCULATIONS MUST BE |
| | BASED ON THE TOTAL LOT PER SECTION 94-442, AND DESIGN |
| | GUIDELINES MUST DEFINE HOW EACH SITE PLAN WILL MEET THE |
| | REQUIREMENTS AND HOW THE OVERALL REQUIREMENTS WILL BE |
| | ADDRESSED AS EACH SITE PLAN IS SUBMITTED. |
| | ? SATISFIED. PROVIDE A PLANT LIST WITH SPECIES AND |
| | SIZES FOR THE LANDSCAPE DEVELOPMENT PLAN. |
| | |
| | ? SATISFIED. PROVIDE THE SEGMENT MEASUREMENT AND |
| | REQUIRED TREES INCLUDING PORTIONS OF THE 30 FOOT |
| | CALCULATION (ROUND UP) FOR ALL BUFFER SEGMENTS. SHOW |
| | PROVIDED NUMBER FOR EACH SEGMENT. |
| | INCLUDE PORTIONS IN REQUIRED, ROUND UP FOR PARTIAL |
| | TREES. |
| | |
| | ? SEE COMMENT #25. DESIGN GUIDELINES DO NOT ADDRESS HOW |
| | THE CALCULATION OF REQUIREMENTS FOR EACH AREA WILL BE |
| | HANDLED. DEFINE WHEN THE BUFFER SEGMENTS WILL BE |
| | INSTALLED THAT ARE INCLUDED IN EACH AFFECTED AREA. |
| | |
| | 2. SATISFIED. PROVIDE A TREE DISPOSITION PLAN BASED ON |
| | THE TREE SURVEY AND SHOW ALL EXISTING TREES TO BE |
| | PRESERVED, RELOCATED OR REMOVED. SOME TREES HAVE BEEN |
| | REMOVED FROM AREAS OF THE SITE WITHOUT A PERMIT. THIS |
| | NEEDS TO BE ADDRESSED. |
| | ? SATISFIED. IDENTIFY TREES ALREADY REMOVED AS SUCH ON |
| | THE CHART. |
| | ? SATISFIED. PROVIDE THE TREE CANOPY DIAMETER FOR ALL |
| | TREES. |
| | ADD A COLUMN PROVIDING THE CANOPY DIAMETER. |
| | ? SATISFIED. PROVIDE THE CATEGORY SQUARE FOOTAGE FOR |
| | TREES LESS THAN 20 FEET IN DIAMETER AND PALMS FOR ANY |
| | REMOVALS FOR MITIGATION DUE. |
| | CORRECT BASED ON CANOPY DIAMETER. |
| | ? SATISFIED. PROVIDE THE ACTUAL SQUARE FOOTAGE FOR ANY |
| | TREES 20 FEET OR MORE IN CANOPY DIAMETER. |
| | CANNOT VERIFY WITHOUT CANOPY DIAMETER. |
| | ? SATISFIED. INDIVIDUAL IDENTIFYING NUMBERS ON THE TREE |
| | DISPOSITION PLAN ARE VERY DIFFICULT TO READ. REVISE TO |
| | MAKE THEM CLEAR. |
| | ? SATISFIED. IDENTIFY WHETHER FICUS BENJAMINAS ARE PART |
| | OF AN UNMAINTAINED HEDGE, OR ARE INDIVIDUAL TREES. |
| | |
| | 3. SATISFIED. PROVIDE THE TOTAL TREE CANOPY SQUARE |
| | FOOTAGE PROVIDED WITH THE PROPOSED LANDSCAPE PLAN ON |
| | THE TREE DISPOSITION PLAN, AS WELL AS THE TOTAL |
| | PROPOSED TO BE REMOVED. |
| | SHOW TOTAL PROPOSED FOR REMOVAL AND CALCULATE CANOPY |
| | CREDITS FOR TREES BEING ADDED FOR THE PROPOSED AFFECTED |
| | AREA. DEFINE WHEN THE TREES WILL BE REMOVED AND WHEN |
| | MITIGATION WILL BE PROVIDED. |
| | |
| | 4. SATISFIED. SECTION 94-448 (D)(3) REQUIRES NATIVE |
| | TREES IN GOOD CONDITION TO BE PRESERVED ON SITE OR |
| | RELOCATED. ANSI A 300 (PART 5) STANDARDS SPECIFY |
| | EXAMPLES OF SUITABILITY RATINGS OF GOOD, MODERATE, OR |
| | POOR FOR RELOCATION. PROVIDE CONDITION FOR ALL EXISTING |
| | TREES AND PALMS AND RELOCATION POTENTIAL FOR THE NATIVE |
| | TREES AND PALMS. |
| | |
| | PROVIDE AN ARBORISTS REPORT ON THE CONDITION AND REASON |
| | THAT THE TREES PROPOSED TO BE REMOVED CANNOT BE |
| | RELOCATED. |
| | |
| | 5. SATISFIED. THERE ARE EXISTING LIVE OAK TREES IN THE |
| | NORTH BUFFER AND ADJACENT TO THE CELL TOWER COMPOUND. |
| | THESE ARE BASED ON AN APPROVED LANDSCAPE PLAN THAT |
| | MEETS THE SCREENING REQUIREMENTS FOR THE TOWER AND |
| | EQUIPMENT. ANY CHANGES PROPOSED TO THE APPROVED |
| | LANDSCAPE PLAN NEED TO BE SHOWN AND INCLUDED ON THE |
| | MASTER PLAN. |
| | |
| | EXPLAIN THE REASON FOR REMOVAL OF LIVE OAK TREE QV-13. |
| | |
| | 6. SATISFIED. THE PROPERTY LINE CHANGE FOR RIGHT OF WAY |
| | DEDICATION NEEDS TO BE FINALIZED TO DETERMINE THE |
| | LOCATION OF OVERHEAD POWER LINES, AS THIS WILL DIRECTLY |
| | AFFECT THE RIGHT TREE RIGHT PLACE CONDITIONS AND |
| | LOCATIONS FOR THE LANDSCAPE BUFFERS. UNDERGROUNDING OF |
| | POWER LINES THAT WILL BE RELOCATED NEEDS TO BE |
| | ADDRESSED. |
| | 7. SATISFIED. LOCATIONS OF FPL TRANSFORMERS AND |
| | LOCATIONS OF UNDERGROUND LINES MUST BE SHOWN, AS THE |
| | TRANSFORMERS MUST BE SCREENED, AND LOCATIONS CANNOT |
| | DISPLACE REQUIRED LANDSCAPING. THIS SHOULD ALSO BE |
| | ADDRESSED IN THE DESIGN GUIDELINES. |
| | 8. SATISFIED. PLEASE CORRECT THE FLORIDA FRIENDLY |
| | LANDSCAPE CHART TO REFLECT CURRENT CODE REQUIREMENT OF |
| | 50 POINTS USING THE DESIGN OPTIONS CONSISTENT WITH |
| | CURRENT CODE 94-442(G). |
| | |
| | WAWA LANDSCAPE PLAN: |
| | |
| | 9. SATISFIED. ALL REFERENCES TO LOT NEED TO BE CHANGED |
| | TO AFFECTED SITE PLAN AREA OR SIMILAR, AS THE APPLICANT |
| | HAS INDICATED THIS WILL NOT BE SUBDIVIDED INTO A |
| | SEPARATE LOT. |
| | |
| | 10. SATISFIED. THERE IS NO WAY OF TELLING THE PARKING |
| | AND LOADING AREAS ADJACENT TO THE INTERNAL ROAD, |
| | RESULTING IN LARGE CONTINUOUS AREAS OF PAVEMENT. SHOW |
| | HOW THESE AREAS WILL BE SEPARATED IF A LANDSCAPE STRIP |
| | IS NOT PROVIDED. |
| | |
| | THE LANDSCAPE STRIP HAS BEEN PROVIDED BUT STOPS SHORT |
| | OF THE FULL LENGTH OF THE LOADING AREA. STAFF WOULD |
| | LIKE TO SEE PAVED AREA MINIMIZED. |
| | |
| | |
| | |
| | 11. SATISFIED. SHOW THE PARKING LANDSCAPE AREAS COUNTED |
| | TOWARD COMPLIANCE WITH SECTION 94-443(C)(3) AND (4) FOR |
| | THE AREAS WITHIN THE PARKING FIELD, AND MATCH THE TOTAL |
| | SHOWN ON THE REQUIREMENT CHART TO MEETING THE TOTAL OF |
| | BOTH SECTIONS ADDED TOGETHER. |
| | PROVIDE AN EXHIBIT IDENTIFYING THE PARKING SPACES, |
| | OTHER VEHICULAR USE AREAS AND SHOWING THE AREAS COUNTED |
| | TOWARD INTERIOR LANDSCAPING. SEE FIGURE XIV-1 IN |
| | SECTION 94-443 TO IDENTIFY AREAS. |
| | PROVIDE A SEPARATE EXHIBIT SHOWING THE AREAS AND SQUARE |
| | FOOTAGES. |
| | |
| | |
| | 12. SATISFIED. UTILITY VALVES AND STRUCTURES INCLUDING |
| | SIGNS MAY NOT BE PLACED IN THE REQUIRED LANDSCAPE AREA |
| | IN PARKING LOT ISLANDS. THIS AREA IS MEANT TO SUPPORT |
| | THE REQUIRED TREE. ISLANDS SHOULD BE EXPANDED TO |
| | PROVIDE SEPARATE AREAS FOR THE UTILITIES. |
| | |
| | |
| | 13. SATISFIED. SHOW THE REQUIRED TREE IN THE TERMINAL |
| | ISLAND AT THE NORTHWEST CORNER OF THE BUILDING AND IN |
| | THE TERMINAL ISLAND ADJACENT TO THE SIGN. |
| | |
| | 14. SATISFIED. SHOW THAT THE REQUIRED PARKING LOT TREES |
| | MEET THE 75% CATEGORY ONE SHADE TREE REQUIREMENT. |
| | REQUIRED TREES INCLUDE ALL TERMINAL ISLAND AND INTERIOR |
| | ISLANDS ADJACENT TO PARKING SPACES. |
| | |
| | 15. SATISFIED. ALL LANDSCAPE ISLANDS MUST MEET THE |
| | REQUIRED LANDSCAPE WIDTH OF 8 FEET INSIDE D CURB AND BE |
| | THE FULL LENGTH OF THE PARKING SPACE INCLUDING THE 6 |
| | INCH D CURB. |
| | |
| | MUST EXTEND THE FULL LENGTH OF THE ADJACENT PARKING |
| | SPACE. |
| | |
| | 16. SATISFIED. ALL PARKING SPACES MUST CONTAIN A WHEEL |
| | STOP OR CURB. STAFF SUGGESTS A CURB AT 16 FEET LENGTH |
| | WITH OVERHANG TO INCREASE THE PERVIOUS AREA. |
| | |
| | 17. SATISFIED. ALL CURBS ADJACENT TO LANDSCAPE AREAS |
| | MUST MEET THE CODE REQUIREMENT OF A TYPE D NON |
| | MOUNTABLE CURB PER SECTION 94-443(C)(5) OR SIMILAR. |
| | |
| | MODIFIED F CURB DETAIL SHOWN MUST BE PROVEN TO BE OF |
| | COMPARABLE DURABILITY TO D CURB PER SECTION |
| | 94-443(C)(5)A. THE D CURB IS NON-MOUNTABLE TO STOP CARS |
| | FROM READILY DRIVING OVER IT. IT ALSO EXTENDS 6 INCHES |
| | ABOVE AND 12 INCHES BELOW THE PAVEMENT LEVEL TO PROVIDE |
| | STRENGTH AND DURABILITY. THE TOTAL 18 INCH PROFILE ALSO |
| | ACTS AS A ROOT BARRIER TO DIRECT TREE ROOTS DOWN AND |
| | MINIMIZE MAINTENANCE. |
| | |
| | 18. SATISFIED. CORRECT THE BUFFER CALCULATIONS TO ROUND |
| | UP FOR ANY PORTIONS OVER THE REQUIRED ONE TREE PER 30 |
| | FOOT REQUIREMENT. |
| | |
| | 19. SATISFIED. EXPLAIN THE LARGE GAP BETWEEN BUFFER |
| | TREES ON THE 45TH STREET SIDE. |
| | |
| | 20. SATISFIED. SHOW COMPLIANCE WITH THE BUILDING |
| | PERIMETER LANDSCAPE REQUIREMENT OF 30% FOR COMMERCIAL |
| | USE AND INCLUDE THE LINEAR FOOTAGE. CLARIFY WHERE THE |
| | 93 FEET CLAIMED CAN BE FOUND, AS ABOVE GROUND PLANTERS |
| | CANNOT BE COUNTED TOWARD PERIMETER LANDSCAPE |
| | REQUIREMENTS. AREAS MUST BE IN THE GROUND. |
| | |
| | PROVIDE MEASUREMENTS OF THE LINEAR SEGMENTS ADJACENT TO |
| | BUILDING FOUNDATION. STAFF COULD ONLY VERIFY 81 FEET |
| | THROUGH SCALE MEASUREMENT. |
| | |
| | 21. SATISFIED. PLEASE CORRECT THE FLORIDA FRIENDLY |
| | LANDSCAPE CHART TO REFLECT CURRENT CODE REQUIREMENT OF |
| | 50 POINTS USING THE DESIGN OPTIONS CONSISTENT WITH |
| | CURRENT CODE 94-442(G). THE SAME PLANTS CANNOT BE |
| | COUNTED MORE THAN ONCE IN THE SAME CATEGORY FOR NATIVE |
| | AND DROUGHT TOLERANT. |
| | |
| | POINTS FOR EACH CATEGORY ARE NOT THE CURRENT CODE. |
| | DOUBLE CHECK ALL WORDING AND POINTS ALLOTTED, AS THERE |
| | ARE DISCREPANCIES. |
| | |
| | 22. SATISFIED. SHOW COMPLIANCE WITH SECTION 94-445 L. |
| | PLANT SPECIES. A MINIMUM OF 60 PERCENT OF PLANT |
| | MATERIAL ADDED SHALL BE FLORIDA NATIVE OR DROUGHT |
| | TOLERANT SPECIES SELECTED FROM THE CITY LIST OR THE |
| | LIST OF SPECIES IN THE MOST RECENT EDITION OF SOUTH |
| | FLORIDA WATER MANAGEMENT DISTRICT WATERWISE SOUTH |
| | FLORIDA LANDSCAPES. SHOW ACTUAL PERCENTAGE ON LANDSCAPE |
| | PLAN. INFORMATION INCLUDED IN LANDSCAPE DATA CHART IS |
| | NOT CONSISTENT WITH WPB CODE. |
| | 23. SATISFIED. PLEASE PROVIDE SCREENING FOR ALL FPL |
| | TRANSFORMERS AND ABOVE GROUND UTILITY VALVES AND |
| | BACKFLOWS PREVENTERS AND SHOW ALL LOCATIONS OF GROUND |
| | MOUNTED EQUIPMENT. |
| | 24. SATISFIED. SHOW LOCATIONS OF LIGHTING ON THE |
| | LANDSCAPE PLAN TO PREVENT CONFLICTS WITH LANDSCAPING. |
| | |
| | ADDITIONAL COMMENTS 8/11/20: |
| | 25. DESIGN GUIDELINES. |
| | ? SATISFIED. 6. LANDSCAPING. STAFF WILL NOT SUPPORT ANY |
| | REDUCTION IN THE NUMBER OF REQUIRED BUFFER TREES. THE |
| | CODE ALLOWS CLUSTERING OF TREES TO ADJUST FOR ANY |
| | CIRCUMSTANCES THAT WOULD INHIBIT PLACEMENT. THERE IS |
| | ALSO FLEXIBILITY THAT ALLOWS PLACEMENT OF BUFFER TREES |
| | ADJACENT INTERIOR TO THE 5 FOOT LANDSCAPE BUFFER IF |
| | SPACE IS AVAILABLE. |
| | STAFF WILL NOT SUPPORT THIS LANGUAGE BEING INCLUDED IN |
| | THE DESIGN GUIDELINES, AND IT WOULD REQUIRE A WAIVER |
| | REQUEST BE INCLUDED IN THE CPD REZONING. |
| | ? SATISFIED. FOUNDATION PLANTING. THE CODE REQUIREMENT |
| | FOR COMMERCIAL STRUCTURES IS 30 PERCENT, AND STAFF |
| | WOULD SUPPORT THE MINIMUM REQUIREMENT. ALL REQUIRED |
| | FOUNDATION PLANTING WOULD HAVE TO BE WITHIN 10 FEET OF |
| | THE FOUNDATION TO MEET THE INTENT, AND ALLOW FOR |
| | VARIATIONS SUCH AS SIDEWALK ACCESS. |
| | ? SATISFIED. AS MENTIONED IN COMMENT #1, IT MUST BE |
| | ESTABLISHED WHEN THE CPD BUFFER SECTIONS WILL BE |
| | REQUIRED TO BE PLANTED. WILL IT BE AHEAD OF INTERNAL |
| | DEVELOPMENT OR AS EACH AFFECTED AREA COMES IN FOR |
| | APPROVAL? |
| | STAFF SUGGESTS INSTALLATION OF THE BUFFERS ALONG |
| | MILITARY TRAIL AND 45TH STREET WITH THE WAWA |
| | CONSTRUCTION TO IMPROVE THE APPEARANCE OF THE OVERALL |
| | PROPERTY, AND THE INSTALLATION OF THE REMAINING |
| | PERIMETER BUFFERS AS EACH ADJACENT AREA IS DEVELOPED. |
| | 26. SATISFIED. WAWA LANDSCAPE PLAN- HIGH RISE LIVE OAKS |
| | ARE NOT ACCEPTABLE IN THIS APPLICATION. PROVIDE |
| | CATHEDRAL OR SPECIES LIVE OAK FOR MEETING THE 25 FOOT |
| | TREE CANOPY REQUIREMENT OF THE CODE FOR SHADE TREE. |
| | |
| | |
| | ADDITIONAL COMMENTS 10/23/20: |
| | WAWA: |
| | 27. SATISFIED. SHEET L-1- CORRECT ITEM 3D. ON THE |
| | FLORIDA FRIENDLY DESIGN OPTIONS TO 10 POINTS. |
| | |
| | 28. SATISFIED. EXHIBIT PLAN PROVIDED ON SHEET L-2 DOES |
| | NOT HAVE THE AREAS REPRESENTED CORRECTLY. ONLY 3 AREAS |
| | NEED TO BE IDENTIFIED AND SQUARE FOOTAGE SHOWN: THE |
| | PARKING SPACES, OTHER VEHICULAR USE AREAS AND THE AREAS |
| | COUNTED TOWARD INTERIOR LANDSCAPING. |
| | 29. SATISFIED. THERE ARE INCONSISTENCIES WITH THE |
| | CIVIL, SITE AND LANDSCAPE PLAN WITH SOME UTILITY |
| | LOCATIONS. THESE NEED TO BE CONSISTENT. A CONDITION MAY |
| | BE INCLUDED TO ASSURE THAT ALL WATER AND SEWER PLAN |
| | CHANGES REVIEWED AND APPROVED BY RIVIERA BEACH PROVIDER |
| | MUST BE REVIEWED AND APPROVED BY PLANNING STAFF TO |
| | ASSURE THE CHANGES MEET CODE REQUIREMENTS. |
| | ADDITIONAL COMMENTS 11/23/20: |
| | |
| | 30. SATISFIED. TREE DISPOSITION PLAN: CALCULATIONS FOR |
| | TREE CANOPY SIZE 20 FEET OR MORE NEED TO BE CORRECTED |
| | FOR THE AREA AS: RADIUS TIMES RADIUS TIMES PI. THIS |
| | WILL CHANGE THE MITIGATION REQUIRED CALCULATIONS. |
| | 31. SATISFIED. SHEET LP-4 NEEDS TO HAVE THE MEDJOOL |
| | TOTAL CANOPY PROVIDED CORRECTED TO 200 (4X50). |
| | 32. SATISFIED. WAWA SITE PLAN SHOWS A CHARGING STATION, |
| | THE LANDSCAPE PLAN DOES NOT. |
| | |
| | |
| | |
| | CONDITIONS OF APPROVAL |
| | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON |
| | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE |
| | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT |
| | SERVICES DEPARTMENT, PLANNING DIVISION. |
| | |
| |