| 2020-05-13 13:18:43 | FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462 |
| | PROJECT: PRIME DEVELOPMENT CPD AND WAWA Z20040014 |
| | MAY 12, 2020 |
| | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND |
| | PROVIDE THE FOLLOWING COMMENTS: |
| | |
| | 1. THE SURVEY, SITE PLAN AND LANDSCAPE PLAN SHOW |
| | INCONSISTENCIES WITH THE OVERALL LANDSCAPE REQUIREMENTS |
| | . THESE NEED TO BE CORRECTED TO DO AN ACCURATE AND |
| | COMPLETE LANDSCAPE REVIEW. SITE CALCULATIONS MUST BE |
| | BASED ON THE TOTAL LOT PER SECTION 94-442, AND DESIGN |
| | GUIDELINES MUST DEFINE HOW EACH SITE PLAN WILL MEET THE |
| | REQUIREMENTS AND HOW THE OVERALL REQUIREMENTS WILL BE |
| | ADDRESSED AS EACH SITE PLAN IS SUBMITTED. |
| | |
| | 2. PROVIDE A TREE DISPOSITION PLAN BASED ON THE TREE |
| | SURVEY AND SHOW ALL EXISTING TREES TO BE PRESERVED, |
| | RELOCATED OR REMOVED. SOME TREES HAVE BEEN REMOVED FROM |
| | AREAS OF THE SITE WITHOUT A PERMIT. THIS NEEDS TO BE |
| | ADDRESSED. |
| | |
| | 3. PROVIDE THE TOTAL TREE CANOPY SQUARE FOOTAGE |
| | PROVIDED WITH THE PROPOSED LANDSCAPE PLAN ON THE TREE |
| | DISPOSITION PLAN, AS WELL AS THE TOTAL PROPOSED TO BE |
| | REMOVED. |
| | |
| | 4. SECTION 94-448 (D)(3) REQUIRES NATIVE TREES IN GOOD |
| | CONDITION TO BE PRESERVED ON SITE OR RELOCATED. ANSI A |
| | 300 (PART 5) STANDARDS SPECIFY EXAMPLES OF SUITABILITY |
| | RATINGS OF GOOD, MODERATE, OR POOR FOR RELOCATION. |
| | PROVIDE CONDITION FOR ALL EXISTING TREES AND PALMS AND |
| | RELOCATION POTENTIAL FOR THE NATIVE TREES AND PALMS. |
| | |
| | 5. THERE ARE EXISTING LIVE OAK TREES IN THE NORTH |
| | BUFFER AND ADJACENT TO THE CELL TOWER COMPOUND. THESE |
| | ARE BASED ON AN APPROVED LANDSCAPE PLAN THAT MEETS THE |
| | SCREENING REQUIREMENTS FOR THE TOWER AND EQUIPMENT. ANY |
| | CHANGES PROPOSED TO THE APPROVED LANDSCAPE PLAN NEED TO |
| | BE SHOWN AND INCLUDED ON THE MASTER PLAN. |
| | |
| | 6. THE PROPERTY LINE CHANGE FOR RIGHT OF WAY DEDICATION |
| | NEEDS TO BE FINALIZED TO DETERMINE THE LOCATION OF |
| | OVERHEAD POWER LINES, AS THIS WILL DIRECTLY AFFECT THE |
| | RIGHT TREE RIGHT PLACE CONDITIONS AND LOCATIONS FOR THE |
| | LANDSCAPE BUFFERS. UNDERGROUNDING OF POWER LINES THAT |
| | WILL BE RELOCATED NEEDS TO BE ADDRESSED. |
| | |
| | |
| | |
| | 7. LOCATIONS OF FPL TRANSFORMERS AND LOCATIONS OF |
| | UNDERGROUND LINES MUST BE SHOWN, AS THE TRANSFORMERS |
| | MUST BE SCREENED, AND LOCATIONS CANNOT DISPLACE |
| | REQUIRED LANDSCAPING. THIS SHOULD ALSO BE ADDRESSED IN |
| | THE DESIGN GUIDELINES. |
| | 8. PLEASE CORRECT THE FLORIDA FRIENDLY LANDSCAPE CHART |
| | TO REFLECT CURRENT CODE REQUIREMENT OF 50 POINTS USING |
| | THE DESIGN OPTIONS CONSISTENT WITH CURRENT CODE |
| | 94-442(G). |
| | |
| | WAWA LANDSCAPE PLAN: |
| | |
| | 9. ALL REFERENCES TO LOT NEED TO BE CHANGED TO AFFECTED |
| | SITE PLAN AREA OR SIMILAR, AS THE APPLICANT HAS |
| | INDICATED THIS WILL NOT BE SUBDIVIDED INTO A SEPARATE |
| | LOT. |
| | |
| | 10. THERE IS NO WAY OF TELLING THE PARKING AND LOADING |
| | AREAS ADJACENT TO THE INTERNAL ROAD, RESULTING IN LARGE |
| | CONTINUOUS AREAS OF PAVEMENT. SHOW HOW THESE AREAS WILL |
| | BE SEPARATED IF A LANDSCAPE STRIP IS NOT PROVIDED. |
| | |
| | 11. SHOW THE PARKING LANDSCAPE AREAS COUNTED TOWARD |
| | COMPLIANCE WITH SECTION 94-443(C)(3) AND (4) FOR THE |
| | AREAS WITHIN THE PARKING FIELD, AND MATCH THE TOTAL |
| | SHOWN ON THE REQUIREMENT CHART TO MEETING THE TOTAL OF |
| | BOTH SECTIONS ADDED TOGETHER. |
| | PROVIDE AN EXHIBIT IDENTIFYING THE PARKING SPACES, |
| | OTHER VEHICULAR USE AREAS AND SHOWING THE AREAS COUNTED |
| | TOWARD INTERIOR LANDSCAPING. SEE FIGURE XIV-1 IN |
| | SECTION 94-443 TO IDENTIFY AREAS. |
| | |
| | 12. UTILITY VALVES AND STRUCTURES INCLUDING SIGNS MAY |
| | NOT BE PLACED IN THE REQUIRED LANDSCAPE AREA IN PARKING |
| | LOT ISLANDS. THIS AREA IS MEANT TO SUPPORT THE REQUIRED |
| | TREE. ISLANDS SHOULD BE EXPANDED TO PROVIDE SEPARATE |
| | AREAS FOR THE UTILITIES. |
| | |
| | |
| | 13. SHOW THE REQUIRED TREE IN THE TERMINAL ISLAND AT |
| | THE NORTHWEST CORNER OF THE BUILDING AND IN THE |
| | TERMINAL ISLAND ADJACENT TO THE SIGN. |
| | |
| | 14. SHOW THAT THE REQUIRED PARKING LOT TREES MEET THE |
| | 75% CATEGORY ONE SHADE TREE REQUIREMENT. REQUIRED TREES |
| | INCLUDE ALL TERMINAL ISLAND AND INTERIOR ISLANDS |
| | ADJACENT TO PARKING SPACES. |
| | |
| | 15. ALL LANDSCAPE ISLANDS MUST MEET THE REQUIRED |
| | LANDSCAPE WIDTH OF 8 FEET INSIDE D CURB AND BE THE FULL |
| | LENGTH OF THE PARKING SPACE INCLUDING THE 6 INCH D |
| | CURB. |
| | |
| | 16. ALL PARKING SPACES MUST CONTAIN A WHEEL STOP OR |
| | CURB. STAFF SUGGESTS A CURB AT 16 FEET LENGTH WITH |
| | OVERHANG TO INCREASE THE PERVIOUS AREA. |
| | |
| | 17. ALL CURBS ADJACENT TO LANDSCAPE AREAS MUST MEET THE |
| | CODE REQUIREMENT OF A TYPE D NON MOUNTABLE CURB PER |
| | SECTION 94-443(C)(5) OR SIMILAR. |
| | |
| | 18. CORRECT THE BUFFER CALCULATIONS TO ROUND UP FOR ANY |
| | PORTIONS OVER THE REQUIRED ONE TREE PER 30 FOOT |
| | REQUIREMENT. |
| | |
| | 19. EXPLAIN THE LARGE GAP BETWEEN BUFFER TREES ON THE |
| | 45TH STREET SIDE. |
| | |
| | 20. SHOW COMPLIANCE WITH THE BUILDING PERIMETER |
| | LANDSCAPE REQUIREMENT OF 30% FOR COMMERCIAL USE AND |
| | INCLUDE THE LINEAR FOOTAGE. CLARIFY WHERE THE 93 FEET |
| | CLAIMED CAN BE FOUND, AS ABOVE GROUND PLANTERS CANNOT |
| | BE COUNTED TOWARD PERIMETER LANDSCAPE REQUIREMENTS. |
| | AREAS MUST BE IN THE GROUND. |
| | |
| | 21. PLEASE CORRECT THE FLORIDA FRIENDLY LANDSCAPE CHART |
| | TO REFLECT CURRENT CODE REQUIREMENT OF 50 POINTS USING |
| | THE DESIGN OPTIONS CONSISTENT WITH CURRENT CODE |
| | 94-442(G). THE SAME PLANTS CANNOT BE COUNTED MORE THAN |
| | ONCE IN THE SAME CATEGORY FOR NATIVE AND DROUGHT |
| | TOLERANT. |
| | |
| | 22. SHOW COMPLIANCE WITH SECTION 94-445 L. PLANT |
| | SPECIES. A MINIMUM OF 60 PERCENT OF PLANT MATERIAL |
| | ADDED SHALL BE FLORIDA NATIVE OR DROUGHT TOLERANT |
| | SPECIES SELECTED FROM THE CITY LIST OR THE LIST OF |
| | SPECIES IN THE MOST RECENT EDITION OF SOUTH FLORIDA |
| | WATER MANAGEMENT DISTRICT WATERWISE SOUTH FLORIDA |
| | LANDSCAPES. SHOW ACTUAL PERCENTAGE ON LANDSCAPE PLAN. |
| | INFORMATION INCLUDED IN LANDSCAPE DATA CHART IS NOT |
| | CONSISTENT WITH WPB CODE. |
| | 23. PLEASE PROVIDE SCREENING FOR ALL FPL TRANSFORMERS |
| | AND ABOVE GROUND UTILITY VALVES AND BACKFLOWS |
| | PREVENTERS AND SHOW ALL LOCATIONS OF GROUND MOUNTED |
| | EQUIPMENT. |
| | 24. SHOW LOCATIONS OF LIGHTING ON THE LANDSCAPE PLAN TO |
| | PREVENT CONFLICTS WITH LANDSCAPING. |
| | |
| | |
| | CONDITIONS OF APPROVAL |
| | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON |
| | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE |
| | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT |
| | SERVICES DEPARTMENT, PLANNING DIVISION. |
| | |
| |