Plan Review Notes
Plan Review Notes For Project Z20030026
Project Number Z20030026
Review Stop PW
Sequence Number 1
Notes
Date Text
2020-03-30 11:04:10PLEASE PROVIDE THE FOLLOWINGS:
  
 1- LOS (LEVEL OF SERVICE ANALYSIS) TO REFLECT THE SOLID
 WASTE VOLUME PRODUCED ALONG WITH THE SIZE AND TYPE OF
 THE CONTAINER (I.E. DUMPSTER/COMPACTOR) THAT WILL BE
 UTILIZED THAT WILL BE UTILIZED FOR THE SANITATION
 SERVICE.
  
 2- WHERE VISIBLE TO THE PUBLIC, COMMERCIAL CONTAINERS
 SHALL BE STORED IN A CITY APPROVED ENCLOSURE
 OBSTRUCTING THE CONTAINERS VIEW FROM PERSONS USING THE
 SIDEWALK, STREET, OR THE COMMERCIAL ESTABLISHMENT'S
 FACILITIES, EXCEPT WHEN ENCLOSURES ARE PROHIBITED, SUCH
 AS IN DOWNTOWN ALLEYS, OR OTHERWISE APPROVED BY THE
 CITY. THIS REQUIREMENT INDICATED IN THE CODE OF
 ORDINANCES, SECTION 74-34-A-2-D.
  
 3- DUMPSTER ENCLOSURE DETAIL. FOR A FREESTANDING SITE
 DUMPSTER ENCLOSURE, THE ENCLOSURE SHALL COMPLY WITH THE
 LATEST REVISION OF CITY OF WEST PALM BEACH GENERAL
 CONSTRUCTION-GARBAGE ENCLOSURE STANDARD, CG-8.
  
 4- AUTO TURN FOR THE SANITATION SERVICE, FRONT LOADER
 TRUCK WITH THE FOLLOWING SPECS:
 - TRUCK LENGTH: 35 FT
 - TRUCK WIDTH: 11 FT
 - TURNING RADIUS:
 - SAE TURNING RADIUS: 32.5 FT
 - CURB-TO-CURB DIAMETER: 74 FT
 - WALL-TO-WALL DIAMETER: 86.3 FT
  
  
 MATT HEJAZI
 DEPT. OF PUBLIC WORKS
 [email protected]
 561-822-2045