| 2020-03-30 11:16:43 | PLEASE PROVIDE THE FOLLOWINGS: | | | | | | 1- LOS (LEVEL OF SERVICE ANALYSIS) TO REFLECT THE SOLID | | | WASTE VOLUME PRODUCED ALONG WITH THE SIZE AND TYPE OF | | | THE CONTAINER (I.E. DUMPSTER/COMPACTOR) THAT WILL BE | | | UTILIZED THAT WILL BE UTILIZED FOR THE SANITATION | | | SERVICE. | | | | | | 2- WHERE VISIBLE TO THE PUBLIC, COMMERCIAL CONTAINERS | | | SHALL BE STORED IN A CITY APPROVED ENCLOSURE | | | OBSTRUCTING THE CONTAINERS VIEW FROM PERSONS USING THE | | | SIDEWALK, STREET, OR THE COMMERCIAL ESTABLISHMENT'S | | | FACILITIES, EXCEPT WHEN ENCLOSURES ARE PROHIBITED, SUCH | | | AS IN DOWNTOWN ALLEYS, OR OTHERWISE APPROVED BY THE | | | CITY. THIS REQUIREMENT INDICATED IN THE CODE OF | | | ORDINANCES, SECTION 74-34-A-2-D. | | | | | | 3- REVISED C-06 SHEET TO RELFECT THE CORRECT REVISION | | | OF THE DUMPSTER ENCLOSURE DETAIL. FOR A FREESTANDING | | | SITE DUMPSTER ENCLOSURE, THE ENCLOSURE SHALL COMPLY | | | WITH THE LATEST REVISION OF CITY OF WEST PALM BEACH | | | GENERAL CONSTRUCTION-GARBAGE ENCLOSURE STANDARD, CG-8. | | | | | | 4- AUTO TURN FOR THE SANITATION SERVICE, FRONT LOADER | | | TRUCK WITH THE FOLLOWING SPECS: | | | - TRUCK LENGTH: 35 FT | | | - TRUCK WIDTH: 11 FT | | | - TURNING RADIUS: | | | - SAE TURNING RADIUS: 32.5 FT | | | - CURB-TO-CURB DIAMETER: 74 FT | | | - WALL-TO-WALL DIAMETER: 86.3 FT | | | | | | | | | MATT HEJAZI | | | DEPT. OF PUBLIC WORKS | | | [email protected] | | | 561-822-2045 |
| |