| Date |
Text |
| 2020-09-09 17:07:21 | FROM: RAY CARANCI, SENIOR LANDSCAPE PLANNER |
| | 561-822-1462 |
| | PROJECT: 2808 N AUSTRALIAN AVE Z20030013 |
| | SEPTEMBER 9, 2020 |
| | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND |
| | PROVIDE THE FOLLOWING COMMENTS: |
| | |
| | 1. PROVIDE THE FOLLOWING CORRECTIONS TO TREE |
| | DISPOSITION CHART: |
| | ? PARTIALLY SATISFIED. PROVIDE THE CANOPY DIAMETERS FOR |
| | THE LIVE OAK TREES #17 AND #19-23. IF THEY ARE LESS |
| | THAN 20 FEET DIAMETER DUE TO FPL PRUNING, THEN THEY |
| | WILL REQUIRE 300 SQ FT MITIGATION. IF THEY ARE 20 FEET |
| | OR MORE, CALCULATE THE ACTUAL SQUARE FOOTAGE AND ENTER |
| | INTO THE MITIGATION DUE COLUMN. |
| | PROVIDE THE CANOPY DIAMETER FOR EACH TREE ON THE CHART. |
| | #17 CHANGED TO BLACK OLIVE SPECIES. |
| | ? SATISFIED. QUEEN PALMS #24 AND 27 ARE CATEGORY 4 , |
| | REQUIRING 50 SQ FT MITIGATION. |
| | ? SATISFIED. JATROPHAS ARE NOT LARGE ENOUGH TO REQUIRE |
| | MITIGATION. ENTER 0 IN THE COLUMN. |
| | ? PARTIALLY SATISFIED. TOTAL THE SQUARE FOOTAGE OF |
| | MITIGATION DUE AND SHOW MITIGATION SQUARE FOOTAGE TOTAL |
| | PROVIDED FROM THE PROPOSED TREE LIST. |
| | RECALCULATE AFTER ANY ADJUSTMENTS FOR ABOVE. |
| | |
| | 2. SATISFIED. CORRECT THE CALCULATIONS FOR REQUIRED |
| | MINIMUM SHADE TREE AND FLOWERING TREE REQUIREMENTS PER |
| | SECTION 94-443(C)(2)B. BASED ON REQUIRED OPEN SPACE OF |
| | 40%. 25750 SQ FT REQUIRES 18 SHADE TREES AND 5 |
| | FLOWERING TREES. |
| | |
| | 3. SATISFIED. CORRECT THE REFERENCE TO SUBSTITUTION OF |
| | PALMS FOR REQUIRED TREES. SECTION 94-442(D) NOW |
| | REQUIRES A 3:1 RATIO FOR SUBSTITUTION. PROVIDE THE |
| | NUMBER OF SUBSTITUTIONS PROPOSED. |
| | |
| | 4. PARTIALLY SATISFIED. SECTION 94-443(C)(3) REQUIRES |
| | THAT A MINIMUM OF 75 PERCENT OF ALL TREES THAT ARE |
| | REQUIRED TO BE PLANTED WITHIN THE INTERIOR OF AN OFF |
| | STREET PARKING AREA SHALL BE CATEGORY 1 SHADE TREES. |
| | REMOVE LANGUAGE REFERRING TO ONE TREE PER 100 SQ FT., |
| | AS THIS WAS REMOVED FROM THE CODE IN 2018. SHOW THE |
| | PERCENTAGE OF CATEGORY 1 TREES PROVIDED FOR THE |
| | REQUIRED LANDSCAPE AREAS AS REQUIRED BY SECTION |
| | 94-443(C)(3) FOR TERMINAL AND INTERIOR ISLANDS. THERE |
| | ARE 11 REQUIRED TREES. |
| | |
| | JAPANESE BLUEBERRY TREES ARE NOT CATEGORY 1, STAFF |
| | SUGGEST CHANGING THE 2 AT THE EAST END OF THE BUILDING |
| | TO A CATEGORY 1 SPECIES, AND THE 75% OF THE 11 REQUIRED |
| | WILL BE MET. |
| | |
| | 5. SATISFIED. PROVIDE A PLAN SHOWING THE PARKING |
| | LANDSCAPE AREAS COUNTED TOWARD COMPLIANCE WITH SECTION |
| | 94-443(C)(3) AND (4) AND PROVIDE CALCULATIONS. PROVIDE |
| | THE TOTAL REQUIRED AND PROVIDED AS ONE TOTAL FOR BOTH |
| | SECTIONS. |
| | |
| | 6. SATISFIED. STAFF SUGGESTS REDUCING THE PAVED AREAS |
| | FOR PARKING SPACES AND USING CURBS INSTEAD OF WHEEL |
| | STOPS TO ALLOW FOR PERVIOUS LANDSCAPE AREA AT THE |
| | OVERHANG. THIS ALSO ALLOWS MORE LANDSCAPE AREA FOR |
| | SUPPORTING THE ROOT ZONES OF THE TREES. |
| | |
| | 7. PARTIALLY SATISFIED. BUFFER LENGTHS REQUIRE ONE TREE |
| | PER 30 FEET OR PORTION THEREOF. EAST BUFFER REQUIRES 7 |
| | TREES, SOUTH BUFFER REQUIRES 11 TREES, NORTH BUFFER |
| | REQUIRES 12 TREES, WEST BUFFER REQUIRES 6 TREES. MAKE |
| | CORRECTIONS. |
| | |
| | CHANGE PROVIDED TREES FOR WEST BUFFER TO 6 IN DATA |
| | CHART. |
| | |
| | 8. PARTIALLY SATISFIED. ADJUST TREE SIZES TO MINIMUM OF |
| | 12 FEET IN HEIGHT. MOVE SPECIES THAT ARE NOT TREES TO |
| | THE SHRUB SECTION. |
| | PINK SHOWER TREE NEEDS TO BE SHOWN AT 12 FEET MINIMUM. |
| | |
| | 9. SATISFIED. ADD A COLUMN TO THE PLANT LIST FOR |
| | DROUGHT TOLERANT LEVELS OF EACH SPECIES. |
| | |
| | 10. SATISFIED. UPDATE THE DESIGN OPTIONS CHART FOR |
| | FLORIDA FRIENDLY LANDSCAPE REQUIREMENTS PER SECTION |
| | 94-442(G) TO THE CURRENT CODE AND PROVIDE THE REQUIRED |
| | 50 POINTS. |
| | |
| | 11. SATISFIED. THE DIVERSITY OF THE TREE SPECIES |
| | PROPOSED ARE VERY LIMITED AND ARE MOSTLY SMALLER |
| | SPECIES. STAFF SUGGESTS AT LEAST 2 SPECIES FOR THE |
| | TREES ON THE EAST AND SOUTH BUFFER UNDER THE FPL LINES, |
| | AND AT LEAST 2 SPECIES ON THE NORTH AND WEST BUFFERS, |
| | USING CATEGORY 1 SHADE TREES TO PROVIDE SHADE FOR THE |
| | PARKING AND PEDESTRIAN AREAS. GREEN BUTTONWOOD AND |
| | SEAGRAPE ARE POSSIBLE ADDITIONS. |
| | |
| | |
| | 12. PARTIALLY SATISFIED. REVISE THE SECTION IN THE |
| | LANDSCAPE DATA CHART TO COMPLY WITH SECTION 94-445 L. |
| | PLANT SPECIES. A MINIMUM OF 60 PERCENT OF PLANT |
| | MATERIAL ADDED SHALL BE FLORIDA NATIVE OR DROUGHT |
| | TOLERANT SPECIES SELECTED FROM THE CITY LIST OR THE |
| | LIST OF SPECIES IN THE MOST RECENT EDITION OF SOUTH |
| | FLORIDA WATER MANAGEMENT DISTRICT WATERWISE SOUTH |
| | FLORIDA LANDSCAPES. |
| | |
| | PROVIDE THE TOTAL PERCENTAGE OF NATIVE AND DROUGHT |
| | TOLERANT PLANTS BASED ON FINAL PLANT LIST. |
| | |
| | 13. PARTIALLY SATISFIED. SHOW LOCATIONS OF FPL |
| | TRANSFORMERS ON THE LANDSCAPE PLAN AND RESOLVE |
| | CONFLICTS WITH LANDSCAPING. |
| | COULD NOT IDENTIFY ON LANDSCAPE OR ENGINEERING PLAN, |
| | RESPONSE TO COMMENTS WAS NOT SUFFICIENT. |
| | |
| | |
| | 14. SATISFIED. SHOW LOCATIONS OF ALL PROPOSED WATER, |
| | SEWER AND DRAINAGE LINES ON THE LANDSCAPE PLAN. |
| | ENGINEERING PLANS WERE NOT SUBMITTED. |
| | |
| | 15. SATISFIED. PROVIDE A DETAIL AND LOCATIONS OF ROOT |
| | BARRIERS TO SEPARATE LANDSCAPING FROM UTILITY LINES. |
| | |
| | 16. PARTIALLY SATISFIED. PROVIDE SCREENING FOR ALL |
| | GROUND MOUNTED VALVES AND EQUIPMENT. |
| | |
| | WATER AND FIRE BACKFLOWS NEED SCREENING HEDGE. |
| | |
| | 17. SATISFIED. SHOW THE LOCATIONS OF ALL SITE LIGHTING |
| | ON THE LANDSCAPE PLAN AND RESOLVE ANY CONFLICTS WITH |
| | TREES. |
| | CONDITIONS OF APPROVAL |
| | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON |
| | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE |
| | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT |
| | SERVICES DEPARTMENT, PLANNING DIVISION. |
| | |
| |
Print |