Plan Review Notes
Plan Review Notes For Project Z20030005
Project Number Z20030005
Review Stop Z
Sequence Number 2
Notes
Date Text
2020-10-22 11:37:18CASE NO. PB 950XXXXX
 575 S. ROSEMARY REDEVELOPMENT
 575 S. ROSEMARY
  
 - CONTACT ERIC SCHNEIDER @ (561) 822-1446,
 [email protected]
  
 - PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN
 WRITTEN FORMAT.
  
 - WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF TWO
 (2) PAPER COPIES AND AN ELECTRONIC COPY IN .PDF FORMAT
 OF ALL PLANS.
  
 1) THE DOCK MANAGER OFFICE AND SHOP (335 SF) NEED TO BE
 INCLUDED IN THE RETAIL NET SF FOR THE PARKING
 CALCULATIONS. NOTE: PARKING REQUIREMENT DOES NOT
 CHANGE.
  
 2) WHAT IS HAPPENING IN THE AREA ON LEVEL 4 THAT IS
 ADJACENT TO THE BAR? IT IS LISTED AS 538 GROSS SQ. FT.,
 BUT NOT HIGHLIGHTED ON SHEET A0.09.
  
 3) PASSAGEWAY:
  
 A. THE NOTE REQUIRING THE PUBLIC SPACE EASEMENT AT THE
 WESTERN TERMINUS OF THE PASSAGEWAY NEEDS TO BE ADDED ON
 DRAWING 1 ON SHEET A0.05. THIS IS REQUIRED BY THE
 DEVELOPMENT REGULATIONS IN RESOLUTION NO. 362-19.
  
 B. THE PASSAGEWAY IS PUBLIC OPEN SPACE; THEREFORE,
 DIRECT ACCESS IS REQUIRED FROM THE NORTH SIDE OF THE
 BUILDING TO THE PASSAGEWAY.
  
 4) PUBLIC OPEN SPACE - PLAZA
  
 A. NO ONE SIDE OF A PLAZA MAY BE 5X THE LENGTH OF
 ANOTHER SIDE. THE HIBISCUS ROW FRONTAGE IS SLIGHTLY
 LESS THAN 9 FEET WHILE THE ROSEMARY ROW FRONTAGE IS
 OVER 109 FEET, WHICH IS 11X LONGER. THIS AREA NEEDS TO
 BE EXCLUDED FROM THE PLAZA AND BECOME A COURTYARD AGAIN
 TO CORRECT THIS.
  
 4) PRIVATE OPEN SPACE - POOL DECK
  
 A. PLEASE VERIFY THAT THE BAR AREA WILL HAVE A SOLID
 ROOF. IF SO, PROVIDE INFORMATION AS TO WHAT THE
 CONSTRUCTION MATERIALS WILL BE.
  
 B. THE OPEN SPACE AREA NEEDS TO ENCOMPASS THE ENTIRE
 CONTIGUOUS 4TH FLOOR AMENITY AREA. YOU MAY NOT
 SELECTIVELY EXCLUDE PORTIONS IN ORDER TO REDUCE THE
 TOTAL AREA TO MEET THE LANDSCAPE MINIMUM.
  
 5) ACTIVE USE
  
 A. THE GROUND LEVEL OF THE HIBISCUS FRONTAGE SHOWS THE
 WESTERN 16 FOOT SECTION AS PART OF THE PROVIDED ACTIVE
 USE. THIS AREA MAY NOT BE INCLUDED SINCE IT DOES NOT
 HAVE THE REQUIRED 25 FOOT DEPTH.
  
 B. ON LEVEL 3, THERE IS A SECTION OF THE MAINTENANCE
 OFFICE THAT NEEDS TO SHOW THAT IT IS A MINIMUM OF 15
 FEET IN DEPTH. IT DOES NOT SCALE AS COMPLYING.
  
 C. THE ACTIVE USE LINER TABLE ON SHEET A0.01 LISTS AN
 INCORRECT DIMENSION FOR THE 3RD LEVEL ALONG HIBISCUS
 STREET. IT IS NOT 182.75 FEET.
  
 6) THE PARKING GARAGE DRAWINGS SHOW THE GARAGE ENTRANCE
 AT THE NORTHEAST CORNER OF THE GARAGE AT THE LOCATION
 WHERE IT CROSSES THE CITYPLACE TOWNHOUSE POA PROPERTY.
 PROVIDE RECORDED DOCUMENTATION FROM THE POA THAT YOU
 ARE PERMITTED TO USE THEIR PROPERTY TO ACCESS THE
 GARAGE OR THIS MAY NOT CHANGE FROM THE LAYOUT APPROVED
 AS PART OF RESOLUTION NO. 362-19. THE PARKING NUMBERS
 NEED TO REFLECT THE FINAL CONFIGURATION.
  
 7) RESIDENTIAL BICYCLE PARKING
  
 A. THE BICYCLE PARKING CALCULATIONS ROUND UP, SO THE
 362 UNITS REQUIRE 37, NOT 36 PARKING SPACES. YOU ARE
 PROVIDING 38 SPACES, SO THIS JUST NEEDS TO BE UPDATED
 ON THE RESIDENTIAL TABLE.
  
 B. THE RESIDENTIAL BICYCLE ROOM SHOWS THREE SPACES THAT
 DO NOT FUNCTION DUE TO THE PROXIMITY TO THE WALL AND
 THE ACCESS PATH. THESE THREE SPACES EXCEED THE 38
 PARKING SPACES THAT ARE PROVIDED AND NEED TO BE
 REMOVED.
  
 8) SHEET A0.01.1 EAST ELEVATION DIAGRAM INCLUDES LABELS
 FOR AREAS E AND F. THESE TWO AREAS DO NOT APPEAR IN THE
 SAME LOCATION/CONFIGURATION ON THE EAST ELEVATION.
 PLEASE CLARIFY.
  
 9) THE ELEVATION MEASURE TO THE TOP OF THE HIGH ROOF ON
 THE ELEVATION DRAWINGS DOES NOT MATCH THE ELEVATION TAG
 ON THE HIGH ROOF PLAN (SHEET A1.07).
  
 10) THE SOUTH ELEVATION DRAWINGS SHOW THAT THE UNITS ON
 THE 5TH LEVEL HAVE BALCONY SLIDER DOORS OVERLOOKING THE
 PODIUM ROOF. THIS GLAZING MAY NOT OPEN TO ACCESS THE
 ROOF, SINCE THE ROOF IS NOT PERMITTED TO HAVE RAILING
 AS IT WOULD EXCEED THE PODIUM HEIGHT. PLEASE CORRECT SO
 THAT THE ACCURATE CONDITIONS ARE SHOWN.
  
 11) PLEASE REMEMBER THAT THE CITYPLACE DRI, REQUIRES
 THAT ALL ROOFTOP MECHANICAL EQUIPMENT BE SCREENED FROM
 PUBLIC VIEW. YOU NEED TO PROVIDE VERIFICATION THAT THIS
 REQUIREMENT IS MET.
  
 A. PROVIDE THE ANTICIPATED HEIGHT OF THE RESIDENTIAL
 CONDENSING UNITS (WITH CURB) AND THE HEIGHT OF THE
 PARAPET WALL AROUND THE CONDENSING UNITS. THIS
 DIMENSION TAG NEEDS TO BE ON BOTH THE ROOF PLAN AND THE
 ELEVATION DRAWINGS.
  
 B. THE ELEVATION DRAWINGS NEED TO SHOW ALL THE ROOFTOP
 FEATURES. THERE ARE MESH LOOKING FEATURES ON EITHER END
 OF THE MAIN ROOF PLAN WHICH DO NOT SHOW ON THE
 ELEVATIONS AND NEED TO BE EXPLAINED AND LABELED.
 ADDITIONALLY, THERE ARE TWO OTHER ROOFTOP FEATURES THAT
 ARE NOT LABELED OR SHOWN ON THE ELEVATIONS (LOOK LIKE
 GENERATORS ON THE PLAN), WHICH NEED TO BE EXPLAINED.
  