Notes
Date Text
2020-03-04 16:55:44FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462
 PROJECT: RACE TRAC 45TH ST Z20020030
 MARCH 4, 2020
 I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND
 PROVIDE THE FOLLOWING COMMENTS:
  
  
 1. ALL CURBS ADJACENT TO LANDSCAPE AREAS MUST MEET THE
 CODE REQUIREMENT OF A TYPE D NON MOUNTABLE CURB PER
 SECTION 94-443(C)(5) OR SIMILAR.
  
 2. IN THE FLORIDA FRIENDLY DESIGN OPTION CHART EACH
 CATEGORY CAN ONLY BE 51% IN ONE, NOT TWO POINTS.
 EXAMPLE: TREES- 51% OR MORE NATIVE AND 25-50% DROUGHT
 TOLERANT ARE POSSIBLE BUT 51% CANNOT BE COUNTED TWICE.
  