| Date |
Text |
| 2020-03-09 11:33:59 | PLEASE PROVIDE THE FOLLOWING: | | | | | | 1- REVISED ENCLOSURE SPEC. SHEETS (A002 AND C-3) TO | | | REFLECT THE CORRECT | | | REVISION OF THE ENCLOSURE SPECS. FOR A FREESTANDING | | | SITE DUMPSTER ENCLOSURE, THE ENCLOSURE SHALL COMPLY | | | WITH THE LATEST REVISION OF CITY OF WEST PALM BEACH | | | GENERAL CONSTRUCTION-GARBAGE ENCLOSURE STANDARD, CG-8. | | | 2- AUTO TURN FOR THE SANITATION SERVICE, FRONT LOADER | | | TRUCK WITH THE | | | FOLLOWING SPECS: | | | - TRUCK LENGTH: 35 FT | | | - TRUCK WIDTH: 11 FT | | | - TURNING RADIUS: | | | - SAE TURNING RADIUS: 32.5 FT | | | - CURB-TO-CURB DIAMETER: 74 FT | | | - WALL-TO-WALL DIAMETER: 86.3 FT | | | | | | MATT HEJAZI | | | DEPT. OF PUBLIC WORKS | | | [email protected] | | | 561-822-2045 |
| |