Plan Review Notes For Project Z20010042
Project Number Z20010042
Review Stop Z
Sequence Number 1
Notes
Date Text
2020-02-12 17:08:04GENERAL:
 1. N/A THE APPLICANT SHALL PAY INTO A FUND TO CITY
 ENGINEERING FOR THE COST OF THE CLEMATIS STREET ROW
 IMPROVEMENTS ALONG THEIR FRONTAGE.
 2. PROPOSED SIDEWALK CAFE SEATING SHALL BE THROUGH A
 SEPARATE SIDEWALK CAFE PERMIT. PLEASE MAKE NOTE ON
 PLANS.
 3. PROPOSED SIGNAGE SHALL MEET THE REQUIREMENTS OF
 SECTION 94-111 AND SHALL BE REVIEWED THROUGH SEPARATE
 PERMIT. PLEASE MAKE NOTE ON PLANS THAT SIGNAGE SHALL BE
 REVIEWED THROUGH SEPARATE PERMIT. THE PROPOSED EVENTS
 LIST CHANGEABLE COPY SIGN IS NOT A PERMITTED TYPE OF
 SIGN (WINDOW SIGNAGE CAN BE CHANGEABLE).
 4. STAFF HAS CONCERNS WITH THE PROPOSE SOUND STAGE AND
 IMPACTS TO SURROUNDING RESIDENTIAL PROPERTIES. PLEASE
 INDICATE HOW THE NOISE ORDINANCE WILL BE MET AND THE
 INTENDED HOURS OF OPERATION. ADDITIONALLY, ARE THERE
 ANY OPPORTUNITIES FOR NOISE PROOFING THE STAGE AREA?
 5. PLEASE PROVIDE A PHOTOMETRIC PLAN WITH RESUBMITTAL.
  
 SITE PLAN/ARCHITECTURAL:
  
 6. PLEASE INCLUDE EXISTING CURBLINE AND PROPOSED NEW
 CURBLINE ON ALL PLANS.
 7. PLEASE EXTEND PLANS TO SHOW BUILDING FRONTAGES OF
 ALL ADJACENT PROPERTIES.
 8. SETBACK DIMENSIONS SHALL BE FROM THE EXISTING
 CLEMATIS STREET BACK OF CURB.
 9. PLEASE INCLUDE SETBACK DIMENSIONS ON SITE PLAN.
 10. PROJECTING OBJECTS, INCLUDING BARS AND OUTWARD
 SWINGING DOORS SHALL MEET THE CONTEXTUAL SETBACK ALONG
 CLEMATIS STREET TO KEEP THE PEDESTRIAN PATHWAY CLEAR OF
 OBSTRUCTIONS. THE PROPOSED SETBACK ALSO DOES NOT APPEAR
 TO CONSIDER THE INCORPORATION OF PLANTERS/VINE
 PLANTINGS AS DEPICTED ON THE RENDERINGS.
 11. QUADRILLE PLACE IS A PRIMARY PEDESTRIAN ROADWAY;
 THE REQUIRED SETBACK IS 16? MINIMUM FROM THE EXISTING
 BACK OF CURB. PROPOSED PROJECTIONS INCLUDING THE BAR
 (NOT INCLUDING CANOPY OR AWNINGS) MUST BE BEHIND THE
 MINIMUM SETBACK.
 12. THE SETBACKS SHALL BE MEASURED TO THE NEAREST POINT
 OF THE STRUCTURE, THIS SHALL INCLUDE ANY PROJECTING
 BARS (NOT INCLUDE CANOPY OR AWNINGS).
 13. THE NEW LAYOUT FOR THE CLEMATIS STREETSCAPE DOES
 NOT MATCH THE LATEST DRAWINGS; PLEASE COORDINATE WITH
 CITY STAFF FOR THE LATEST PLANS.
 14. PLEASE CONFIRM CALCULATIONS FOR PERCENT BUILDING
 COVERAGE WITH DEFINITION FOR FOOTPRINT IN SECTION
 94-109.
 15. PLEASE PROVIDE EXHIBITS FOR THE FOLLOWING:
 A. FAR
 B. TRANSPARENCY
 C. PLANAR BREAK
 D. ACTIVE USE
 E. HORIZONTAL PROJECTIONS
 SEE DEFINITIONS OF EACH IN SECTION 94-109 AND MORE
 DETAIL IN TABLE IV (AT THE END OF SECTION 94-109 ON
 MUNICODE).
 16. PLEASE SHOW ALL PROPOSED ABOVE GROUND UTILITIES
 (BACKFLOW PREVENTER, FDC, WATER METER, TRANSFORMERS,
 GENERATORS FOR FOOD TRUCKS, ETC.). TRANSFORMERS,
 BACKFLOW PREVENTER, FDC SHALL NOT BE LOCATED ALONG
 CLEMATIS STREET. LOCATE AS CLOSE TO ALLEYWAY AND OFF
 PUBLIC ROW AS POSSIBLE.
 17. PLEASE PROVIDE REQUIRED AND PROVIDED BICYCLE RACK
 IN SITE PLAN DATA. BICYCLE PARKING IS REQUIRED AT 1/100
 FEET OF ROW (CLEMATIS AND QUADRILLE PLAZA).
 18. PLEASE PROVIDE BICYCLE RACK DETAIL (NO WAVE RACKS,
 MUST HAVE TWO POINTS OF CONNECTION E.G. POST AND LOOP,
 INVERTED U, ETC.)
 19. IF ARTIFICIAL TURF IS PROPOSED, PLEASE LABEL.
 ARTIFICIAL TURF SHALL BE COUNTED AS IMPERVIOUS AREA IN
 CALCULATIONS.
 20. PLEASE RELABEL STREET NAME TO ?QUADRILLE PLAZA
 DRIVE?
 21. FENCES ALONG THE ALLEY (REAR PROPERTY LINE) CAN BE
 A MAXIMUM OF SIX FEET.
 22. THE PROPOSED FENCE FEATURES ALONG CLEMATIS STREET
 AND QUADRILLE PLAZA DRIVE NEED TO MEET THE FENCE
 REQUIREMENTS OF MAXIMUM FOUR FEET ALONG STREET
 FRONTAGES OR SHALL BE REDESIGNED AS AN ENTRY FEATURE
 THAT IS CONSIDERED A FA?ADE. STAFF CAN PROVIDE MORE
 DETAIL.
 23. HAS THE APPLICANT CONSIDERED THE INTERACTION WITH
 THE FPL PLANT AND POTENTIAL MEASURES TO INTERACT WITH
 THE STRUCTURES
 24. PLEASE INCLUDE SPECIFIC DETAIL OF DUMPSTER
 ENCLOSURE AREA INCLUDING BASE (MUST BE CONCRETE PAD),
 DIMENSIONS AND ENCLOSURE WALL MATERIAL. THE MATERIAL
 MUST BE BRICK, DECORATIVE CONCRETE, OTHER DECORATIVE
 MASONRY, OR COMPARABLY DURABLE WOOD AND STEEL. THE
 WALLS SHALL BE LANDSCAPED WITH SHRUBS AND HEDGES
 PLANTED AT TWO FOOT INTERVALS. A DUMPSTER ENCLOSURE
 SIZE REQUIREMENT IS 14?2? BY 13?8? UNLESS OTHERWISE
 SPECIFIED BY THE CITY?S PUBLIC WORKS DEPARTMENT.
 CONTACT MATT HEJAZI FOR MORE INFORMATION (SEE PUBLIC
 WORKS COMMENTS)
 25. PROVIDE ALL DOCUMENTS SUBMITTED FOR HPB REVIEW.
  
 ARCHITECTURAL:
  
 26. PLEASE PROVIDE DAY TIME RENDERINGS.
 27. PLEASE PROVIDE INTERIOR ELEVATIONS.
 28. ARCHITECTURAL RENDERINGS SHALL SHOW LANDSCAPE AT
 BASE PLANTING HEIGHT AND THE CLEMATIS STREETSCAPE SHALL
 BE COORDINATED WITH LATEST CLEMATIS SCHEMATICS.
 29. PLEASE UPDATE ARCHITECTURAL PLANS TO MATCH ALL SITE
 PLAN CHANGES.
 30. PLEASE LABEL ROOFTOP MOUNTED EQUIPMENT AND INDICATE
 HOW THE EQUIPMENT WILL BE SCREENED. ROOFTOP EQUIPMENT
 SHALL BE SCREENED AT THE EQUIPMENT HEIGHT.
  
  
 31. PLEASE MAKE NOTE ON PLANS, ALL WALL MOUNTED
 EQUIPMENT SHALL BE PAINTED TO MATCH BUILDING FA?ADE.
 32. PLEASE SEE HISTORIC COMMENTS FOR ADDITIONAL
 ARCHITECTURAL COMMENTS, SUBJECT TO HPB REVIEW.
 CIVIL:
 33. THE PROPOSED LAYOUT OF THE PLAN DOES NOT MATCH THE
 PROPOSED SITE PLAN. PLEASE COORDINATE.
 34. THE EXISTING BACKFLOW PREVENTER ON THE CITY?S
 PROPERTY SERVICES ALL IRRIGATION ON QUADRILLE PLAZA.
 THIS WILL NEED TO BE RELOCATED ON SITE AS THE OFFICE
 STRUCTURE IS PROPOSED AT THE CURRENT LOCATION.
  
 STAFF RESERVES THE RIGHT TO MAKE ADDITIONAL COMMENTS
 THROUGHOUT THE REVIEW PROCESS.
  
  
 LIZ LEVESQUE, URBAN DESIGN PLANNER
 [email protected]
 561 822 1426