| 2020-06-11 10:59:58 | *** THE FOLLOWING COMMENTS HAVE BEEN PROVIDED FOR THE |
| | PLANS RECEIVED/STAMPED BY STAFF ON 5/22/2020 *** |
| | |
| | GENERAL COMMENTS: |
| | |
| | 1.) SINCE THE PROJECT IS PROPOSED FOR AN OFFICE |
| | COMMERCIAL PLANNED DEVELOPMENT (OCPD), THE PROJECT |
| | SHOULD BE RENAMED "HOLIDAY INN PBI OFFICE COMMERCIAL |
| | PLANNED DEVELOPMENT (OCPD)." |
| | |
| | 2.) ANY CHANGES TO ANY INFORMATION AND/OR CALCULATIONS |
| | ON THE PLAN SHEET(S) SHALL BE MADE CONSISTENT WITH ALL |
| | OTHER SHEETS IN THE PLAN SET. |
| | |
| | 3.) BASED ON THE NUMBER OF WAIVERS THE APPLICATION IS |
| | SEEKING, THE APPLICANT MAY WISH TO GENERATE DESIGN |
| | REGULATIONS (I.E. MINIMUM SETBACKS) FOR THE PROPOSED |
| | OCPD. |
| | |
| | 4.) THERE STILL SEEMS TO BE SOME CONFUSION WITH THE |
| | NUMBER OF ROOMS IN THE EXISTING HOTEL (I.E. 200 ROOMS |
| | VS. 199 ROOMS). STAFF HAS DOCUMENTATION THAT THERE ARE |
| | 200 ROOMS IN THE EXISTING HOTEL, AND INFORMATION |
| | PROVIDED IN THE JUSTIFICATION STATEMENT, PARKING STUDY, |
| | SITE PLAN, ETC. SEEMS TO BE INCONSISTENT (I.E. |
| | INTERCHANGE BETWEEN 200 ROOMS AND 199 ROOMS IN THE |
| | SUBMITTED DOCUMENTS) . AT THIS POINT, STAFF IS |
| | REQUESTING DOCUMENTATION THAT THE NUMBER OF ROOMS HAD |
| | BEEN REDUCED FROM 200 ROOMS TO 199 ROOMS; OTHERWISE, |
| | PLEASE ENSURE THE INFORMATION ON THE NUMBER OF ROOMS IS |
| | CORRECTED FOR ACCURACY. |
| | |
| | 5.) PLEASE ADDRESS THE FOLLOWING IN THE JUSTIFICATION |
| | STATEMENT: A) SURROUNDING USES TABLE IS INACCURATE. B) |
| | THE PROPOSED PROJECT DOES NOT CONFORM TO THE APPLICABLE |
| | PORTIONS OF THE CITY CODE (OTHERWISE THERE WOULD BE NO |
| | NEED TO REQUEST ANY WAIVERS!). C) MUST IDENTIFY ALL |
| | WAIVERS IN THE PROPOSED PD, INCLUDING ANY |
| | JUSTIFICATION, BENEFITS AND MITIGATION MEASURES (IF |
| | ANY) TO MINIMIZE THE IMPACT OF THE WAIVER REQUESTS. D) |
| | JUSTIFICATION FOR THE PARKING WAIVER IS INSUFFICIENT. |
| | |
| | [2/10/2020 REPEAT COMMENT: ALTHOUGH THE APPLICANT HAS |
| | ADDRESSED THE MAJORITY OF STAFF'S ISSUES AND CONCERNS |
| | WITH THE JUSTIFICATION STATEMENT, THE ABOVE ARE STILL |
| | OUTSTANDING.] |
| | |
| | 6.) PLEASE CLARIFY IF THE DATE OF THE HOTEL MARKET |
| | FEASIBILITY STUDY IS CORRECT. THE MARKET FESIBILITY |
| | STUDY IS DATED APRIL 8, 2019. |
| | |
| | |
| | PLANNED DEVELOPMENT (CRITERIA) COMMENTS: |
| | |
| | 1.) THE PLANS SHOW THE SUBJECT PROPERTY WILL BE DIVIDED |
| | INTO SEPARATE PARCELS/TRACTS BY PROPERTY LINE. IF THE |
| | APPLICANT INTENDS TO SUBDIVIDE THE PROPERTY, ALL |
| | EXISTING AND PROPOSED STRUCTURES WITHIN EACH SUBDIVIDED |
| | PARCEL WILL BE REQUIRED TO MEET THE MINIMUM DEVELOPMENT |
| | REGULATIONS, BUILDING SETBACKS, LANDSCAPING |
| | REQUIREMENTS, ETC., AS STAND-ALONE PARCELS AND AS A |
| | PARCEL AS A WHOLE. IF THE MINIMUM REQUIREMENTS OF THE |
| | ZLDRS CANNOT BE MET, THE APPLICANT WILL BE REQUIRED TO |
| | SEEK WAIVERS FROM THOSE REQUIREMENTS. ALL WAIVERS MUST |
| | BE IDENTIFIED AND REQUESTED IN THE APPLICATION. BASED |
| | ON STAFF'S REVIEW OF THE CURRENT PLANS/APPLICATION, |
| | ADDITIONAL WAIVERS WILL NEED TO BE REQUESTED. |
| | |
| | [2/10/2020 REPEAT COMMENT: NOT ALL REQUIRED WAIVERS |
| | HAVE BEEN REQUESTED IN THE APPLICATION (I.E. LOADING |
| | ZONE. THERE IS ALSO CONFLICTING INFORMATION REGARDING |
| | THE WAVIER REQUEST FROM THE REQUIRED LANDSCAPE BUFFERS |
| | AND WHAT IS DEPICTED IN THE PLANS.] |
| | |
| | 2.) COMMENTS ON THE REQUESTED PARKING WAIVER: A) FAILS |
| | TO MEET THE MINIMUM THREE STANDARDS REQUIRED FOR A |
| | PARKING WAIVER. THEREFORE, STAFF CANNOT SUPPORT THE |
| | PARKING WAIVER AT THIS TIME. |
| | |
| | [2/10/2020 REPEAT COMMENT: STAFF DOES NOT BELIEVE THE |
| | PROJECT HAS MADE ALL THE NECESSARY IMPROVEMENTS TO |
| | ADDRESS THE CONCEPTS OF NEW URBANISM FOR PROJECT |
| | SUPPORT.] |
| | |
| | 3.) THE ORIENTATION OF THE BUILDINGS, ARCHITECTURAL |
| | STYLE/ELEMENTS (EXISTING AND PROPOSED) AND SITE DESIGN |
| | LACKS ENGAGEMENT WITH THE STREET AND CONNECTIVITY WITH |
| | ADJACENT/NEARBY USES, DESIRED ELEMENTS OF A PLANNED |
| | DEVELOPMENT. MORE EFFORT IS NEEDED TO ADDRESS THIS |
| | DESIGN DEFICIENCY. |
| | |
| | [2/10/2020 REPEAT COMMENT: EMPHASIS ON THE |
| | ARCHITECTURAL ELEMENTS AND SITE DESIGN SHOULD BE ALONG |
| | BELVEDERE ROAD, SINCE THE PROJECT FRONTS AND IS HIGHLY |
| | VISIBLE ALONG THIS STREET FRONTAGE. ALSO, THE PROJECT |
| | LACKS THE CONNECTIVITY WITH THE PARCELS AND EXISTING |
| | STREET NETWORK OUTSIDE OF THE DEVELOPMENT AND BUILDING |
| | ENGAGEMENT WITH THE STREET.] |
| | |
| | 4.) SINCE THE APPLICANT IS REQUESTING A REZONING TO A |
| | PLANNED DEVELOPMENT, IT IS EXPECTED THAT AS PART OF THE |
| | APPLICATION FOR A PD THAT ALL PARCELS (PARCELS A AND B |
| | AND AS A PD AS A WHOLE) ARE IMPROVED/UPGRADED TO MEET |
| | AND/OR EXCEED THE MINIMUM REQUIREMENTS OF THE ZLDRS. |
| | THE SUBMITTAL SUGGESTS THAT ONLY IMPROVEMENTS WILL BE |
| | MADE TO PARCEL B (NEW HOTEL SITE), WHICH IS NOT |
| | ACCEPTABLE. |
| | |
| | [2/10/2020 REPEAT COMMENT: FEW IMPROVEMENTS HAVE BEEN |
| | MADE TO PARCEL A (EXISTING HOTEL SITE). ADDITIONAL |
| | IMPROVEMENTS CAN BE MADE TO ADDRESS BUILDING ENGAGEMENT |
| | WITH THE STREET AND CONNECTION WITH THE EXISTING STREET |
| | NETWORK.] |
| | |
| | |
| | MASTER DEVELOPMENT PLAN COMMENTS (SHEET MP-1): |
| | |
| | 1.) INCLUDE INFORMATION ON THE FUTURE LAND USE (FLU) |
| | DESIGNATION, ZONING DESIGNATION AND EXISTING USES FOR |
| | THE ADJACENT USES TO THE NORTH, SOUTH, EAST AND WEST TO |
| | DEMONSTRATE COMPATIBILITY BETWEEN THE EXISTING USES AND |
| | THE PROPOSED USES WITHIN THE CPD. |
| | |
| | [2/10/2020 REPEAT COMMENT: REQUESTED INFORMATION NOT |
| | PROVIDED IN THE 5/22 RESUBMITTAL PLANS.] |
| | |
| | 2.) SHOW THE EXISTING AND PROPOSED USE OF ALL LAND WITH |
| | IN THE PROJECT BOUNDARIES, INCLUDING THE LOCATION OF |
| | ALL AREAS PROPOSED TO BE DEDICATED OR RESERVED FOR |
| | COMMUNITY OR PUBLIC USE. |
| | |
| | [2/10/2020: REQUESTED INFORMATION NOT PROVIDED IN THE |
| | MASTER DEVELOPMENT PLAN.] |
| | |
| | 3.) SHOW THE LOCATION AND SIZE AS APPROPRIATE OF ALL |
| | EXISTING AND PROPOSED DRAINAGE, WATER, SEWER AND OTHER |
| | UTILITY SERVICE SYSTEMS. |
| | |
| | [2/10/2020 REPEAT COMMENT: EXISTING LIFT STATION, FPL |
| | AND UTILITY EASEMENTS, AS PROVIDED IN THE SIGNED AND |
| | SEALED SURVEY ARE NOT DEPICTED AND/OR LABELED IN THE |
| | MASTER DEVELOPMENT PLAN.] |
| | |
| | 4.) PERIMETER LANDSCAPE BUFFERS FOR PARCELS A AND B |
| | HAVE BEEN ILLUSTRATED IN THE MASTER DEVELOPMENT PLAN. |
| | THE LOCATION OF SOME OF THE BUFFERS ARE IN CONFLICT |
| | WITH THE WAIVER REQUEST TO THE REQUIRED BUFFERS. |
| | LANDSCAPE BUFFERS SHOULD ONLY BE ILLUSTRATED WHERE |
| | BUFFERS ARE PROVIDED IN THE MASTER DEVELOPMENT PLAN. |
| | |
| | 5.) ACCORDING TO THE INFORMATION PROVIDED IN THE MASTER |
| | PLAN, THE EXISTING BUILDING SQUARE FOOTAGE FOR PARCEL A |
| | (EXISTING HOTEL) IS 136,660 SQ. FT. BUT CAN BE |
| | INCREASED UP TO 158,981 SQ. FT. (DIFFERENCE OF +22,321 |
| | SQ. FT.). SIMILAR BUILDING INFORMATION IS PROVIDED FOR |
| | PARCEL B (PROPOSED HOTEL): THE PROPOSED HOTEL IS 60,634 |
| | SQ. FT. BUT CAN BE INCREASED UP TO 101,063 SQ. FT. |
| | (DIFFERENCE OF +40,429 SQ. FT.). PLEASE EXPLAIN THE |
| | PURPOSE OF THE EXCESS BUILDING SQUARE FOOTAGE, AS STAFF |
| | HAS CONCERNS THAT THE PROPOSED CPD FALLS SHORT ON THE |
| | CITY'S PARKING REQUIREMENTS AND THE APPLICATION IS |
| | SEEKING A PARKING REDUCTION TO ADDRESS THE PARKING |
| | NEEDS OF THE PROJECT. |
| | |
| | 6.) PROPOSED INTERNAL ROADWAY SYSTEM AND CROSS ACCESS |
| | POINTS DEPICTED IN THE MASTER PLAN IS INCONSISTENT WITH |
| | THE INTERNAL ROADWAY SYSTEM AND CROSS ACCESS POINTS |
| | DEPICTED IN THE PLAT. PLEASE ADDRESS FOR CONSISTENCY. |
| | |
| | 7.) A TWO-WAY INTERNAL DRIVE AISLE SHALL BE A MINIMUM |
| | OF 24 FT. WIDE. PLEASE DIMENSION OUT THE INTERNAL DRIVE |
| | AISLE TO DEMONSTRATE COMPLIANCE. [ZLDR S.94-485] |
| | |
| | 8.) THE EXISTING AND PROPOSED PARCEL LAYOUTS SHALL BE |
| | SHOWN IN THE MASTER DEVELOPMENT PLAN TO ILLUSTRATE HOW |
| | THE PARCELS AND USES WILL BE INTEGRATED WITHIN THE CPD. |
| | |
| | 9.) PARCEL DIMENSIONS SHALL BE PROVIDED IN THE MASTER |
| | DEVELOPMENT PLAN. THE DIMENSIONS SHALL BE CONSISTENT |
| | WITH THE INFORMATION PROVIDED IN THE PROPOSED PLAT FOR |
| | CONSISTENCY. |
| | |
| | 10.) PLEASE ADDRESS THE FOLLOWING IN THE "OVERALL |
| | PLANNED DEVELOPMENT DATA TABULAR": A) GROSS SITE AREA |
| | SHALL MATCH THE NUMBERS PROVIDED IN THE SIGNED AND |
| | SEALED SURVEY. B) PARCEL SIZE INFORMATION SHALL BE |
| | CORRECTED FOR CONSISTENCY WITH ANY CHANGES MADE TO THE |
| | CALCULATIONS. C) THE PROPOSED CUMULATIVE FAR FOR |
| | PARCELS A AND B SHALL BE PROVIDED IN THE APPROPRIATE |
| | UNIT MEASUREMENT (I.E. FAR IS NOT MEASURED IN SQUARE |
| | FEET). D) TABULAR IS MISSING MINIMUM REQUIRED/PROVIDED |
| | LOT SIZE INFORMATION. E) REQUIRED AND PROVIDED |
| | CALCULATION SHALL BE PROVIDED FOR THE FOLLOWING: |
| | MAXIMUM LOT COVERAGE, MAXIMUM IMPERMEABLE SURFACE, |
| | MINIMUM LANDSCAPING, MINIMUM OPEN SPACE, MINIMUM |
| | BUILDING SEPARATION. F) REQUIRED AND PROVIDED LANDSCAPE |
| | BUFFER CALCULATIONS SHALL BE PROVIDED. |
| | |
| | 11.) PLEASE ADDRESS THE FOLLOWING IN THE "PARCEL A SITE |
| | DATA TABULAR": A) LABEL COLUMNS FOR THE REQUIRED AND |
| | PROVIDED CALCULATIONS, AND VERIFY THE CALCULATIONS ARE |
| | PROVIDED IN THE CORRECT COLUMNS. B) PLEASE EXPLAIN THE |
| | PROPOSED 19.5 FT. LOT WIDTH. C) SOME OF THE |
| | INFORMATION PROVIDED IN THE TABLE CAN BE MINIMIZED |
| | (I.E. FAR "ALLOWED" INFORMATION CAN BE ELIMINATED, AS |
| | IT IS ALREADY PROVIDED IN THE OVERALL DEVELOPMENT |
| | TABULAR). D) "BUILDING NAME" SHALL BE CHANGED TO |
| | "BUILDING USE" WHICH IS MORE APPROPRIATE. E) IT IS |
| | UNNECESSARY TO STATE IF THE STANDARDS OF THE CODE HAVE |
| | BEEN MET (I.E. YES/NO). PLEASE ELIMINATE TO SIMPLIFY |
| | THE TABLE. F) PROVIDE THE HEIGHT OF THE EXISTING HOTEL |
| | IN FEET. G) CHECK CALCULATIONS FOR THE FOLLOWING: |
| | MAXIMUM LOT COVERAGE, MAXIMUM IMPERMEABLE SURFACE, |
| | MINIMUM LANDSCAPING AND MINIMUM OPEN SPACE. H) CORRECT |
| | BUILDING SETBACK INFORMATION (SOME SETBACKS PROVIDED IN |
| | THE TABULAR DO NOT SEEM TO THE BE SHORTEST DISTANCE |
| | FROM THE BUILDING TO THE PROPERTY LINE). I) ASTERISKS |
| | SHALL ONLY BE PROVIDED BY THE WAIVER REQUEST (NOT |
| | REQUIRED STANDARDS). J) WAIVER REQUIRED FOR: FRONT |
| | SETBACK |
| | |
| | 12.) PLEASE ADDRESS THE FOLLOWING IN THE "PARCEL B SITE |
| | DATA TABULAR": A) LABEL COLUMNS FOR THE REQUIRED AND |
| | PROVIDED CALCULATIONS, AND VERIFY THE CALCULATIONS ARE |
| | PROVIDED IN THE CORRECT COLUMNS. B) THERE SHOULD BE NO |
| | CORNER SETBACK FOR PARCEL B ? PLEASE ADDRESS. C) SOME |
| | OF THE INFORMATION PROVIDED IN THE TABLE CAN BE |
| | MINIMIZED (I.E. FAR ?ALLOWED? INFORMATION CAN BE |
| | ELIMINATED, AS IT IS ALREADY PROVIDED IN THE OVERALL |
| | DEVELOPMENT TABULAR). D) "BUILDING NAME" SHALL BE |
| | CHANGED TO "BUILDING USE" WHICH IS MORE APPROPRIATE. E) |
| | IT IS UNNECESSARY TO STATE IF THE STANDARDS OF THE CODE |
| | HAVE BEEN MET (I.E. YES/NO). PLEASE ELIMINATE TO |
| | SIMPLIFY THE TABLE. F) PROVIDE THE HEIGHT OF THE |
| | EXISTING HOTEL IN FEET. G) CHECK CALCULATIONS FOR THE |
| | FOLLOWING: MAXIMUM LOT COVERAGE, MAXIMUM IMPERMEABLE |
| | SURFACE, MINIMUM LANDSCAPING AND MINIMUM OPEN SPACE. H) |
| | CORRECT BUILDING SETBACK INFORMATION (SOME SETBACKS |
| | PROVIDED IN THE TABULAR DO NOT SEEM TO THE BE SHORTEST |
| | DISTANCE FROM THE BUILDING TO THE PROPERTY LINE). I) |
| | ASTERISKS SHALL ONLY BE PROVIDED BY THE WAIVER REQUEST |
| | (NOT REQUIRED STANDARDS). |
| | |
| | 13.) BUILDING SETBACKS SHALL BE MEASURED AS THE |
| | SHORTEST DISTANCE FROM THE BUILDING TO THE PROPERTY |
| | LINES. SOME OF THE SETBACKS PROVIDED IN THE PLANS DO |
| | NOT SEEM TO BE THE SHORTEST DISTANCE FROM THE |
| | BUILDING(S) TO THE PROPERTY LINES. |
| | |
| | |
| | PARCEL A SITE PLAN COMMENTS: |
| | |
| | 1.) PROVIDE EVIDENCE THAT THERE IS AN EXISTING |
| | RESTRICTIVE COVENANT FOR THE 22 PARK N' FLY SPACES. |
| | STAFF DOES NOT HAVE ANY DOCUMENTATION THAT A |
| | RESTRICTIVE COVENANT EXISTS. THE LANGUAGE IN THE SITE |
| | PLAN SHALL BE CORRECTED FOR CONSISTENCY IF NO |
| | RESTRICTIVE COVENANT FOR THE PARK N? FLY SPACES EXISTS. |
| | |
| | 2.) PARCEL DIMENSIONS MISSING FOR PARCEL A. DIMENSIONS |
| | FOR THE PARCEL SHALL BE PROVIDED IN THE PLAN AND SHALL |
| | BE CONSISTENT WITH THE DIMENSIONS PROVIDED IN THE |
| | PROPOSED PLAT DOCUMENT. |
| | |
| | 3.) DIMENSIONS (I.E. PARKING STALLS/CURB OVERHANGS (IF |
| | APPLICABLE), DRIVE AISLES, LOADING ZONES, ETC.) ARE |
| | MISSING FROM THE SITE PLAN. THE DIMENSIONS ARE |
| | NECESSARY TO DEMONSTRATE COMPLIANCE WITH THE MINIMUM |
| | DIMENSIONAL STANDARDS OF THE ZLDRS. |
| | |
| | 4.) ARE WHEEL STOPS PROVIDED OR WILL THERE BE A 2 FT. |
| | CURB OVERHANG? WHEEL STOPS WILL NEED TO BE ILLUSTRATED |
| | IN THE PLAN IF PROVIDED. |
| | |
| | 5.) SOME BUILDING SETBACKS DO NOT SEEM TO BE MEASURED |
| | FROM THE SHORTEST DISTANCE FROM THE BUILDING TO THE |
| | PROPERTY LINE. PLEASE RECALCULATE FOR ACCURACY. |
| | |
| | 6.) EXPLAIN THE WAIVER REQUEST TO THE MINIMUM LOT |
| | WIDTH. IF IS DIFFICULT FOR STAFF TO VERIFY THE REQUEST |
| | WHEN THERE ARE NO DIMENSIONS IN THE PLANS. |
| | |
| | 7.) WAIVERS SHALL BE REQUESTED FOR THE FOLLOWING: A) |
| | FRONT SETBACK B) SIDE SETBACK C) LOADING ZONES D) |
| | LANDSCAPE BUFFERS. |
| | |
| | 8.) HOW HIGH IS THE EXISTING WALL THAT CONNECTS TO THE |
| | PROPOSED 4 FT. HIGH DECORATIVE SECURITY FENCE? PLEASE |
| | NOTATE IN THE PLAN. |
| | |
| | 9.) BICYCLE PARKING REQUIRED. SHOW LOCATION OF BICYCLE |
| | RACKS AND CALCULATIONS IN THE PLANS. |
| | |
| | 10.) ANY INCONSISTENCIES IN THE SITE DATA TABULAR FOR |
| | PARCEL A SHALL BE CORRECTED. |
| | |
| | |
| | PARCEL B SITE PLAN COMMENTS: |
| | |
| | 1.) PARCEL DIMENSIONS MISSING FOR PARCEL B. DIMENSIONS |
| | FOR THE PARCEL SHALL BE PROVIDED IN THE PLAN AND SHALL |
| | BE CONSISTENT WITH THE DIMENSIONS PROVIDED IN THE |
| | PROPOSED PLAT DOCUMENT. |
| | |
| | 2.) DIMENSIONS (I.E. PARKING STALLS/CURB OVERHANGS (IF |
| | APPLICABLE), DRIVE AISLES, LOADING ZONES, |
| | WALKWAYS/SIDEWALKS, ETC.) ARE MISSING FROM THE SITE |
| | PLAN. THE DIMENSIONS ARE NECESSARY TO DEMONSTRATE |
| | COMPLIANCE WITH THE MINIMUM DIMENSIONAL STANDARDS OF |
| | THE ZLDRS. |
| | |
| | 3.) THERE IS A NEW SIDEWALK FROM THE MAIN FRONT |
| | ENTRANCE OF THE PROPOSED HOTEL THAT ENDS ALONG THE |
| | FRONTAGE ROAD. THIS IS UNACCEPTABLE. THE SIDEWALK SHALL |
| | CONNECT TO AN EXISTING/NEW SIDEWALK FOR CONTINUOUS |
| | CONNECTION AND INTEGRATION OF THE PLANNED DEVELOPMENT. |
| | |
| | 4.) WAIVERS SHALL BE REQUESTED FOR THE FOLLOWING: A) |
| | FRONT SETBACK B) LANDSCAPE BUFFERS C) LOADING ZONE |
| | REQUIREMENTS. |
| | |
| | 5.) LOADING ZONE SEEMS TO BE MISSING FROM THE SITE |
| | PLAN. |
| | |
| | 6.) THE WEST SIDE SETBACK SEEMS TO BE 52.97 FT. AND NOT |
| | 67.70 FT. PLEASE EXPLAIN THIS DISCREPANCY. |
| | |
| | 7.) PARCEL B DOES NOT ABUT A CORNER, AND THEREFORE, |
| | THERE SHOULD BE NO CORNER SETBACK. PLEASE ADDRESS. |
| | |
| | 8.) THE PARKING TABULAR INDICATES A TOTAL OF 6 COMPACT |
| | PARKING SPACES. PLEASE IDENTIFY THE LOCATION OF THESE |
| | COMPACT SPACES WITHIN THE PLAN. |
| | |
| | 9.) PLEASE ADDRESS THE FOLLOWING IN THE PARKING |
| | TABULAR: A) 114 PARKING SPACES HAVE BEEN |
| | COUNTED/IDENTIFIED IN THE PROJECT (NOT 115 PARKING |
| | SPACES). B) A MAXIMUM OF 40 COMPACT SPACES ARE |
| | PERMITTED (NOT 41 COMPACT SPACES). |
| | |
| | 10.) ANY INCONSISTENCIES IN THE SITE DATA TABULAR FOR |
| | PARCEL B SHALL BE CORRECTED. |
| | |
| | |
| | SITE PLAN DETAILS COMMENTS: |
| | |
| | 1.) PARKING STALL DETAIL SHALL BE REVISED FOR |
| | CONSISTENCY WITH THE CITY'S STANDARDS FOR STALL |
| | STRIPING. |
| | |
| | 2.) PROVIDE A SITE-SPECIFIC DETAIL (WITH DIMENSIONS) OF |
| | THE BICYCLE RACKS. THE LOCATION AND RACK SEPARATION |
| | SHALL BE CONSISTENT WITH THE CITY?S BICYCLE PARKING |
| | DESIGN GUIDELINES. |
| | |
| | |
| | ARCHITECTECTURAL COMMENTS: |
| | |
| | 1.) IT IS REQUESTED THAT ADDITIONAL ARCHITECTURAL |
| | FEATURES BE PROVIDED ON THE SOUTH ELEVATION SINCE IT IS |
| | THE ELEVATION THAT IS MOST VISIBLE FROM THE STREET. |
| | ALSO, NOTE THAT IT MAY BE HELPFUL TO PROVIDE COLORED |
| | ELEVATIONS FOR THE PROPOSED HOTEL. |
| | |
| | 2.) ALL ROOFTOP MECHANICAL EQUIPMENT SHALL BE SCREENED |
| | FROM VIEW. PLEASE DEMONSTRATE COMPLIANCE/PROVIDE A NOTE |
| | IN THE PLAN. |
| | |
| | |
| | SIGNAGE COMMENTS: |
| | |
| | 1.) THE MAXIMUM SUM TOTAL AREA OF ALL LOW FREESTANDING |
| | SIGNS ON FRONT STREET: 1 SQ. FT. FOR EACH 1 LINEAR FOOT |
| | OF FRONT STREET FRONTAGE OF THE LOT WHICH IT IS |
| | LOCATED. THERE ARE NO PARCEL DIMENSIONS PROVIDED IN THE |
| | PLANS TO CALCULATE AND VERIFY THE SIGN AREA COMPLIANCE |
| | WITH THE ZLDRS. [ZLDR S.94-408(A)(2)] |
| | |
| | [2/10/2020 REPEAT COMMENT: PROPOSED SIGN AREA SQUARE |
| | FOOTAGE NOT PROVIDED.] |
| | |
| | |
| | PHOTOMETRIC PLAN COMMENTS: |
| | |
| | 1.) ANY SOURCE OF ILLUMINATION LOCATED WITHIN THE |
| | PROPOSED PD SHALL NOT EXCEED ONE-FOOT CANDLE AT OR |
| | BEYOND THE BOUNDARIES OF THE DEVELOPMENT. ILLUSTRATE |
| | FOOT CANDLE SPILLOVER TO DEMONSTRATE COMPLIANCE. [ZLDR |
| | S.94-309(A)] |
| | |
| | [2/10/2020 REPEAT COMMENT: SPILLOVER WAS NOT PROVIDED |
| | FOR THE ENTIRE DEVELOPMENT (PARCELS A AND B)] |
| | |
| | 2.) ALL EXTERIOR LIGHTING SHALL BE SHIELDED TO REDUCE |
| | GLARE AND SHALL BE ARRANGED TO REFLECT LIGHT OR GLARE |
| | AWAY FROM PUBLIC THOROUGHFARES. [ZLDR S.94-309(A)] |
| | |
| | [2/10/2020 REPEAT COMMENT: AT MINIMUM, A NOTE SHALL BE |
| | PROVIDED IN THE PHOTOMETRIC PLAN FOR COMPLIANCE.] |
| | |
| | |
| | INSTRUCTIONS FOR RESUBMITTAL: |
| | |
| | * PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN |
| | WRITTEN FORMAT. |
| | |
| | * ANY CHANGES ON THE RESUBMITTED PLANS MAY RESULT IN |
| | ADDITIONAL COMMENTS. |
| | |
| | * WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF |
| | FIFTEEN (15) PAPER COPIES, ONE (1) REDUCED COPY IN 8.5 |
| | INCHES X 11 INCHES AND ONE (1) SET IN 11 INCHES X 17 |
| | INCHES, AND AN ELECTRONIC COPY OF ALL PLANS. |
| | |
| | * PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1) |
| | RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY-ISSUED |
| | COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE |
| | APPLICANT WILL BE ASSESSED A RESUBMITTAL FEE. SUCH |
| | RESUBMITTAL FEE WILL BE 20% ($600.00) OF THE ORIGINAL |
| | APPLICATION FEE. |
| | |
| | * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE |
| | QUESTIONS. |
| |