Plan Review Notes
Plan Review Notes For Project Z20010013
Project Number Z20010013
Review Stop ENG - PPRC
Sequence Number 2
Notes
Date Text
2020-06-11 11:58:06COMMENTS FROM RICK ROSSANO, PROJ. COORDINATOR, CITY OF
 WPB ENG. SERVICES, 561-494-1098.
  
 PLEASE CLEARLY LABEL BELVEDERE RD ROW.
 PLEASE PROVIDE STORMWATER CCTV ALONG ENTIRE PROJECT
 FRONTAGE.
 PLEASE REMOVE STANDARD DETAIL WS-2 FROM DETAILS AND
 ADJUST PLANS AS RELATED.
  
 COMMENTS FROM MARK HURLEY, FIELD CUSTOMER SERVICE
 SUPERVISOR, CITY OF WEST PALM BEACH PUBLIC UTILITIES,
 561-822-2262 :
  
 PREVIOUS COMMENTS:
  
 RE: SHEET C-8 UTILITY EASEMENT - BACKFLOW ASSEMBLIES
 CANNOT BE IN THE UTILITY EASEMENTS ? PLEASE UPDATE
 PLAN. WOULD ALSO NEED UE FOR NEW IRRIGATION WATER
 SERVICE AND METER BOX. ON BOUNDARY & TOPOGRAPHY SURVEY
 (SHEET V-2), THERE IS A LISTED UTILITY EASEMENT ? IF
 THAT STILL EXISTS MAYBE IT CAN BE INCORPORATED ON SHEET
 C-8. IF NOT EXISTS, THEN ALSO WOULD LIKE UTILITY
 EASEMENTS FOR EXISTING WATER SERVICES TO EXISTING
 HOTEL. CIVIL PLAN ALSO SHOWS A WATER MAIN APPROACHING
 THOSE WATER SERVICES FROM ROAD. PLEASE VERIFY IF THAT
 IS DRAWN CORRECTLY AND IF CITY-OWNED. IF SO, THEN NEED
 UE FOR THAT ALSO.
  
 RE: SHEET C-8 IRRIGATION - THERE SHOULD BE NO REDUCER.
 1.5 IN. OR 2 IN. METERS BOTH HAVE 2 IN. SERVICE LINES
 PER SD & AML. THE CURBSTOPS ARE THE UNIVERSAL TYPE THAT
 ACCOMMODATES EITHER SIZE METER. PLEASE UPDATE C-8.
  
 NEW COMMENTS:
  
 -PLEASE LABEL FIRELINE POINT OF SERVICE GATE VALVE
 ADJACENT TO WATER MAIN.
  
 -DEMOLITION PLAN DID NOT HAVE A LABEL WITH WHAT IS
 HAPPENING TO OLD EXISTING IRRIGATION WATER SERVICE AND
 BACKFLOW PREVENTER FOR EXISTING HOTEL. AS-BUILT PLAN
 ALSO SHOWS IT ARRANGED DIFFERENTLY. PLEASE VERIFY
 CONFIGURATION. IS IT GOING TO BE CUT & CAPPED, REMOVED,
 OR LEFT IN PLACE AS-IS? THERE WAS ANOTHER COMMENT
 RELATED TO THIS FROM ENGINEERING.
  
 -ON ENGINEERING SUBMITTAL, PLEASE LABEL CONFLICT
 CROSSINGS FOR IRRIGATION WATER SERVICE WITH FM & SS AND
 PROVIDE RESOLUTION.
  
 -A SIDEWALK ABRUPTLY ENDS BEFORE THE IRRIGATION WATER
 METER BOX. IF ANTICIPATE CONTINUING SIDEWALK LATER OR
 HEAVY FOOT TRAFFIC OVER METER BOX, PLEASE RELOCATE
 METER BOX SLIGHTLY NORTH OUT OF THE WAY.
  Print


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved