2020-02-12 11:45:53FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462
 FEBRUARY 12, 2020
 PROJECT: MINOR SUBDIVISION Z20010014
 1. SUBDIVISION LINE WITHIN THE OCPD WILL REQUIRE A
 WAIVER TO THE LANDSCAPE BUFFER REQUIREMENTS PER SECTION
 94-443 (B) ALONG BOTH SIDES OF THE SUBDIVISION LINE.
  
 PROJECT: HOLIDAY INN OCPD Z20010013
 I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND
 PROVIDE THE FOLLOWING COMMENTS:
  
 1. THE EXISTING SITE AND PARKING AREA LANDSCAPE
 NONCONFORMITIES MUST BE REDUCED AS PART OF THE OCPD
 REZONING. THERE IS A CERTIFICATE OF CONFORMITY ISSUED
 BY THE CITY FOR PORTIONS OF THE WESTERN BUFFER, AND
 STAFF WILL LOCATE THE INFORMATION TO CLARIFY THE EXTENT
 OF THE APPROVAL. THE SITE IS REVIEWED IN TOTAL FOR
 COMPLIANCE WITH LANDSCAPE CODE REQUIREMENTS AND AS
 INDIVIDUAL PARCELS. IF THE REQUIREMENTS CANNOT BE MET,
 THEN THE APPLICANT MUST REQUEST WAIVERS FROM THOSE
 REQUIREMENTS.
  
 2. PROVIDE THE CALCULATIONS FOR MINIMUM NUMBER OF
 REQUIRED SHADE TREES, FLOWERING TREES AND SHRUBS PER
 SECTION 94-443(C)(2)B. BASED ON REQUIRED OPEN SPACE OF
 40% OF THE ENTIRE OCPD, AND SHOW WHAT IS PROVIDED TO
 MEET THE REQUIREMENT.
  
 3. SHOW THE REQUIRED 5 FOOT LANDSCAPE BUFFER ADJACENT
 TO THE RIGHT OF WAY AND THE 5 FOOT LANDSCAPE BUFFER
 PLANTINGS ALONG ALL OTHER PROPERTY LINES ON THE
 LANDSCAPE PLAN WITH THE REQUIRED TREES OR NUMBER OF
 SUBSTITUTE PALMS PER CURRENT CODE REQUIREMENTS OF
 SECTION 94-443(B). SHOW ALL CALCULATIONS FOR THE
 REQUIRED TREES FOR BUFFER SEGMENTS ON A PERIMETER
 BUFFER REQUIREMENT CHART INCLUDING LINEAR FOOTAGE OF
 ALL PROPERTY LINE SEGMENTS. IF THE BUFFER CANNOT BE
 PROVIDED ALONG THE PROPERTY LINE, A WAIVER MUST BE
 REQUESTED, AND ALTERNATIVES PRESENTED TO PROVIDE
 COMPARABLE BUFFERING ON THE SITE. LIST EACH BUFFER
 SEGMENT AND SHOW THE REQUIRED AND PROVIDED TREES FOR
 EACH.
  
 4. SHOW EXISTING LANDSCAPING AND TREES ON ADJACENT
 PROPERTIES WITHIN 10 FEET OF THE PROPERTY LINE PER
 SECTION 94-442(B)(2)Q.
  
 5. PROVIDE THE LINEAR FEET OF PLANTINGS FOR BUILDINGS
 PER SECTION 94-443(E)(1).
  
  
 6. PROVIDE THE REQUIRED TREES IN TERMINAL LANDSCAPE
 ISLANDS, INTERIOR ISLANDS AND DIVIDER ISLANDS PER
 SECTION 94-443(C)(3).
  
 7. PROVIDE AN EXHIBIT SHOWING THE PARKING AREA SURFACE
 CALCULATIONS, PARKING SPACE AREAS AND LANDSCAPE AREAS
 PROVIDED TO DEMONSTRATE COMPLIANCE WITH SECTIONS 94-443
 (C)(3) AND (4), FOLLOWING THE AREA CLASSIFICATIONS AS
 SHOWN IN FIGURE XIV-1.
  
 8. SECTION 94-443(C)(3) REQUIRES THAT A MINIMUM OF 75
 PERCENT OF ALL TREES THAT ARE REQUIRED TO BE PLANTED
 WITHIN THE INTERIOR OF AN OFF STREET PARKING AREA SHALL
 BE CATEGORY 1 SHADE TREES. SHOW THE PERCENTAGE OF
 CATEGORY 1 TREES PROVIDED FOR THE REQUIRED LANDSCAPE
 AREAS.
  
 9. MAKE THE FOLLOWING CORRECTIONS TO THE TREE
 DISPOSITION PLAN:
 ? PROVIDE THE TOTAL MITIGATION DUE FOR THE REMOVED
 PALMS.
 ? INCLUDE A CHART FOR TREE MITIGATION PROVIDED BASED ON
 THE PLANT LIST AND PROVIDE THE TOTAL FOR THE SQUARE
 FOOTAGE.
  
 10. GROUP PLANT LIST AS TREES, PALMS, SHRUBS AND
 GROUNDCOVER /GRASS.
  
 11. PROVIDE MINIMUM HEIGHT OF 12 FEET FOR ALL TREES.
  
 12. ADD A COLUMN TO THE PLANT LIST TO IDENTIFY NATIVE
 SPECIES RATHER THAN INCLUDING IN THE SPECIES COLUMN.
  
 13. ADD RELOCATED PALMS TO THE PLANT LIST AND COUNT
 THEM TOWARD THE REQUIRED TREES.
  
 14. SHOW ALL WATER, SEWER AND DRAINAGE LINES ON THE
 LANDSCAPE PLAN, RESOLVE ANY CONFLICTS WITH LANDSCAPING.
  
 15. PROVIDE LOCATIONS AND SCREENING FOR ALL ABOVE
 GROUND UTILITY VALVES, BACKFLOW PREVENTERS, A/C UNITS,
 AND FPL TRANSFORMERS.
  
 16. PROVIDE A PRELIMINARY IRRIGATION PLAN PER SECTION
 94-442(B)(2)M.
  
 17. PROVIDE LOCATIONS OF LIGHTING ON THE LANDSCAPE PLAN
 TO AVOID CONFLICTS WITH LANDSCAPING.
  
  
 18. SHOW LOCATIONS OF ANY ROOT BARRIERS REQUIRED TO
 PROTECT UTILITY LINES AND PROVIDE A ROOT BARRIER
 DETAIL.
  
 19. PROVIDE THE FLORIDA FRIENDLY LANDSCAPE CHART AND
 THE MINIMUM 50 POINTS PER SECTION 94-443(G) BASED ON
 THE PLANT LIST AND ITEMS THAT QUALIFY.
  
 20. SHOW COMPLIANCE WITH SECTION 94-445 L. PLANT
 SPECIES. A MINIMUM OF 60 PERCENT OF PLANT MATERIAL
 ADDED SHALL BE FLORIDA NATIVE OR DROUGHT TOLERANT
 SPECIES SELECTED FROM THE CITY LIST OR THE LIST OF
 SPECIES IN THE MOST RECENT EDITION OF SOUTH FLORIDA
 WATER MANAGEMENT DISTRICT WATERWISE SOUTH FLORIDA
 LANDSCAPES.
 PROVIDE THE TOTAL PERCENTAGE OF ADDED PLANT MATERIAL
 THAT QUALIFIES.
  
 CONDITIONS OF APPROVAL
 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON
 THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE
 SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT
 SERVICES DEPARTMENT, PLANNING DIVISION.
  