| 2020-02-12 13:08:41 | GENERAL COMMENTS |
| | 1. REVISE THE PROJECT NUMBER IN THE SITE DATA TABLE |
| | 2. PROVIDE A LEGEND FOR SYMBOLS/LINES. |
| | 3. CORRECT THE NUMBER OF REQUIRED BICYCLE PARKING IN |
| | THE SITE DATA TABLE. |
| | 4. CLARIFY THE SITE DATA TABLE (SOME NUMBERS ARE |
| | PROPOSED, SOME PROVIDED--THIS PROVIDES CONFUSION ON |
| | ITEMS THAT HAVE NEITHER DESIGNATION). |
| | 5. PROVIDE MISSING ELEMENTS (PERCENT OF IMPERVIOUS |
| | AREA, PERCENT OF WATER BODIES). |
| | 6. WHAT OFFICE USE IS BEING USED FOR THE OFFICE PARKING |
| | CALCULATION IN THE DATA TABLE? |
| | 7. CORRECT THE MAX. BUILDING HEIGHT ON THE SITE DATA |
| | TABLE. |
| | |
| | SITE PLAN COMMENTS |
| | 1. PROVIDE A DETAIL OF THE STORAGE TRAILERS |
| | 2. PROVIDE THE DIMENSION STORAGE TRAILERS AND DISTANCE |
| | OF THE STORAGE TRAILERS TO THE PROPERTY LINES |
| | 3. PURSUANT ZLDR SEC. 94-315(B)(1), SCREENING . OUTDOOR |
| | STORAGE OF GOODS, MERCHANDISE AND MATERIALS SHALL NOT |
| | BE PERMITTED UNLESS ENCLOSED ON ALL SIDES BY A WALL OF |
| | ADEQUATE HEIGHT CONSTRUCTED OF BRICK, DECORATIVE |
| | CONCRETE, OTHER DECORATIVE MASONRY, OR COMPARABLY |
| | DURABLE WOOD OR STEEL. PLEASE REMOVE THE EXISTING CHAIN |
| | LINKED FENCE AND REPLACE WITH A WALL TO COMPLY WITH |
| | ZONING REGULATIONS. |
| | 4. PURSUANT ZLDR SEC. 94-174(5), MAXIMUM BUILDING |
| | HEIGHT: 50 FEET. REVISE THE BUILDING HEIGHT TO COMPLY |
| | WITH ZONING REGULATIONS. |
| | 5. PROVIDE THE HEIGHT OF THE SECURITY GATE. |
| | 6. PROVIDE THE DIMENSIONS OF THE PROPOSED ANGLE PARKING |
| | SPACES. |
| | 7. PROVIDE ALL DIMENSIONS OF PARKING AREAS/SPACES. |
| | 8. 16 FEET PARKING STALLS MAY BE USED FOR PARKING IF |
| | THERE IS AN OVERHANG PROVIDED OVER A LANDSCAPED AREA. |
| | 18 FEET PARKING WITH A WHEEL STOP IS REQUIRED IN PLACES |
| | WHERE A CURB AND OVERHANG OVER LANDSCAPED MATERIAL IS |
| | NOT PROVIDED. PROVIDE CLARITY BETWEEN THE SOD A AND |
| | OTHER MATERIALS ON THE PLAN AS IT IS CURRENTLY UNCLEAR. |
| | 9. HOW WILL PEDESTRIANS ACCESS THE STRUCTURE FROM THE |
| | PARKING AREA? |
| | 10. IS THE EXISTING CONCRETE DRIVEWAY TO BE REMOVED? IF |
| | SO, REMOVE ON PLANS. |
| | 11. IS ACCESS TO THE PROPOSED LOADING SPACE OR DUMPSTER |
| | BLOCKED BY EQUIPMENT STORAGE? CLARIFY OR SHOW ACCESS ON |
| | THE PLANS. |
| | 12. CLARIFY STORAGE LINES AND EQUIPMENT MERCHANDISE |
| | STORAGE AREAS ON THE PLANS. IT IS CURRENTLY UNCLEAR. |
| | 13. IT IS HIGHLY RECOMMENDED TO SWITCH THE ORIENTATION |
| | OF THE PROPOSED STRUCTURE AND PARKING LOT TO HAVE THE |
| | STRUCTURE CLOSER TO THE FRONT OF THE LOT. |
| | 14. INCLUDE A PHOTOMETRIC PLAN TO SHOW SITE LIGHTING |
| | (LOCATION, HEIGHT, AND INTENSITY OF ANY OUTDOOR |
| | LIGHTING). |
| | 15. IS ROOFTOP MATERIAL PROPOSED ON THE STRUCTURE? |
| | 16. DIMENSION PROPOSED MONUMENT SIGN. |
| | 17. INDICATE IF THE DESIGNATED STORAGE AREAS ARE OPEN |
| | AIR OR COVERED CANOPY. |
| | |
| | IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO |
| | CONTACT ME. |
| | |