| Date |
Text |
| 2020-01-06 17:04:21 | FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462 |
| | PROJECT: MORSELIFE CSPD MAJOR AMENDMENT Z19120007 |
| | JANUARY 6, 2020 |
| | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND |
| | PROVIDE THE FOLLOWING COMMENTS: |
| | |
| | 1. PROVIDE A TREE SURVEY AND TREE DISPOSITION PLAN AND |
| | LIST SHOWING ALL EXISTING TREES ON THE AFFECTED AREA |
| | AND EXISTING SOUTH BUFFER. |
| | |
| | 2. REVISE THE LANDSCAPE DATA CHART TO REFLECT CURRENT |
| | CODE REQUIREMENTS FOR SHADE TREES, FLOWERING TREES AND |
| | PALM SUBSTITUTIONS PER SECTION 94-442(C)(2)B. |
| | CALCULATIONS ARE BASED ON 50% REQUIRED OPEN SPACE FOR |
| | CSPD. |
| | |
| | 3. INDICATE THE LANDSCAPE BUFFER LOCATIONS ON THE SITE |
| | PLAN AND LANDSCAPE PLAN. IF THIS PARCEL IS TO REMAIN |
| | SEPARATE WITHIN THE CSPD, THE BUFFER MUST REMAIN UNLESS |
| | A WAIVER IS REQUESTED FOR INTERNAL PARCEL LINE BUFFERS. |
| | |
| | 4. SHOW ALL CALCULATIONS FOR THE REQUIRED TREES FOR |
| | BUFFER SEGMENTS ON A PERIMETER BUFFER REQUIREMENT CHART |
| | INCLUDING LINEAR FOOTAGE OF ALL PROPERTY LINE SEGMENTS |
| | INCLUDING PHASE 1 AND PHASE 2. |
| | |
| | 5. SECTION 94-443(C)(3) REQUIRES THAT A MINIMUM OF 75 |
| | PERCENT OF ALL TREES THAT ARE REQUIRED TO BE PLANTED |
| | WITHIN THE INTERIOR OF AN OFF STREET PARKING AREA SHALL |
| | BE CATEGORY 1 SHADE TREES. SHOW THE PERCENTAGE OF |
| | CATEGORY 1 TREES PROVIDED FOR THE REQUIRED LANDSCAPE |
| | AREAS. |
| | |
| | 6. PROVIDE AN EXHIBIT SHOWING THE PARKING AREA SURFACE |
| | CALCULATIONS, PARKING SPACE AREAS AND LANDSCAPE AREAS |
| | PROVIDED TO DEMONSTRATE COMPLIANCE WITH SECTIONS 94-443 |
| | (C)(3) AND (4). |
| | LIST THE CALCULATIONS ON THE DATA CHART COMPLYING WITH |
| | CURRENT CODE REQUIREMENTS. |
| | |
| | 7. THERE ARE TERMINAL LANDSCAPE ISLANDS MISSING THE |
| | REQUIRED TREE. FIRE HYDRANTS, FDC AND OTHER UTILITIES |
| | CANNOT DISPLACE THE REQUIRED TREES. UTILITY CHANGES |
| | WITHIN THE PHASE 2 AREA CONFLICT WITH REQUIRED TREES. |
| | |
| | 8. PROVIDE LOCATIONS OF LIGHTING ON THE LANDSCAPE PLAN |
| | TO AVOID CONFLICTS WITH LANDSCAPING. |
| | |
| | 9. THERE APPEAR TO BE CONFLICTS IN SEVERAL LOCATIONS |
| | BETWEEN TREES AND WATER AND SEWER LINES ON THE |
| | LANDSCAPE PLAN. ADJUST LOCATIONS OF TREES OR UTILITY |
| | LINES TO RESOLVE CONFLICTS WITH LANDSCAPING. |
| | 10. CHECK THE FLORIDA FRIENDLY DESIGN POINTS CHART TO |
| | CORRECT ALL LANGUAGE AND POINTS TO THE CURRENT CODE. |
| | TREES CANNOT BE COUNTED AS 51% IN TWO CATEGORIES. |
| | . |
| | 11. SHOW LOCATIONS OF ANY ROOT BARRIERS REQUIRED TO |
| | PROTECT UTILITY LINES AND PROVIDE A ROOT BARRIER |
| | DETAIL. |
| | |
| | 12. PROVIDE LOCATIONS AND SCREENING FOR ALL ABOVE |
| | GROUND UTILITY VALVES, BACKFLOW PREVENTERS, A/C UNITS, |
| | AND FPL TRANSFORMERS. |
| | |
| | 13. SHOW COMPLIANCE WITH SECTION 94-445 L. PLANT |
| | SPECIES. A MINIMUM OF 60 PERCENT OF PLANT MATERIAL |
| | ADDED SHALL BE FLORIDA NATIVE OR DROUGHT TOLERANT |
| | SPECIES SELECTED FROM THE CITY LIST OR THE LIST OF |
| | SPECIES IN THE MOST RECENT EDITION OF SOUTH FLORIDA |
| | WATER MANAGEMENT DISTRICT WATERWISE SOUTH FLORIDA |
| | LANDSCAPES. |
| | MODIFY CALCULATIONS FOR ONLY ADDED PLANTS, AND INCLUDE |
| | LOW WATER USE PLANTS. |
| | |
| | |
| | CONDITIONS OF APPROVAL |
| | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON |
| | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE |
| | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT |
| | SERVICES DEPARTMENT, PLANNING DIVISION. |
| | |
| |
Print |