2020-12-14 19:58:32TRAFFIC STUDY COMMENTS:
 1. BANYAN/ROSEMARY SYNCHRO ANALYSIS:
 1A. PLEASE CLARIFY WHY THE FUTURE SCENARIO HAS OVERALL
 LESS DELAY THAN THE BACKGROUND ONE, AS SHOWN IN TABLE 3
 AND 4, RESPECTIVELY
 1B. PLEASE PROVIDE SYNCHRO OUTPUT SHOWCASING QUEUE
 STORAGE LENGTH SETTING/ASSUMPTIOS
 1C. BACKGROUND AND FUTURE SCENARIO NETWORK SHALL BE
 CODED ACCORDING TO THE ON-GOING BANYAN BOULEVARD
 STREETSCAPE PROJECT?S ROADWAY PLANS. THE CITY CAN
 PROVIDE SUCH PLANS.
  
 SITE PLAN COMMENTS:
 2. PROVIDE AUTOTURN PATH FOR SERVICE AND DELIVERY
 VEHICLES. THE CITY CODE PROHIBITS VEHICLES FROM BACKING
 INTO AND OUT OF PUBLIC RIGHT-OF-WAY. THE ITEM WAS NOT
 PROVIDED TO THE TRAFFIC ENGINEER.
 3. PROVIDE TURNAROUND SPACE AT THE DEAD-END ON THE 5TH
 FLOOR OR TOP FLOOR OF THE PARKING GARAGE PER CITY CODE
 REQUIREMENT. AUTOTURN ANALYSIS NEEDED TO VERIFY AND
 VALIDATE. PLEASE PROVIDE REFERENCE SHEET NAME/NUMBER,
 AS THE LATEST SUBMISSION DOES NOT SHOWCASE ANY REVISION
 ON THE MATTER.
 4. REDUCE WIDTH OF THE ONE-WAY DRIVEWAY TO 12 FEET.
 PROVIDE DIMENSIONS FOR DRIVING ISLES, DRIVEWAYS AND
 PARKING STALLS. IF ALREADY PRESENTED, PLEASE PROVIDE
 REFERENCE SHEET NUMBER. LATEST SUBMISSION DOES NOT
 PROVIDE THE REQUESTED REVISIONS IN SHEET SP-1.
 5. CONSIDER RELOCATING THE MIDBLOCK CROSSWALK ON 3RD
 STREET TO ALIGN WITH PROPOSED DEVELOPMENT WALKWAY.
 PROVIDE SUPPORTING DOCUMENTATION SHOWCASING APPLICABLE
 SAFETY AND VISIBILITY REQUIREMENTS DISQUALIFYING SUCH
 RELOCATION.
 6. PROVIDE A MICRO-MOBILITY AREA WITH THE FOLLOWING
 CHARACTERISTICS:
 6A. 8? X 20? DIMENSIONS
 6B. LOCATED NEAR AN ENTRANCE AND ACCESSIBLE TO THE
 PUBLIC
 6C. PROVIDE A CONDUIT (2" SCHEDULE 40 PVC) TO THE POWER
 SOURCE WITH AN ELECTRICAL PULL BOX (240V CIRCUIT)
 7. COORDINATE WITH CITY STAFF FOR FURTHER TDM
 STRATEGIES
  
 NOTED COMMENTS:
 - EASEMENT WILL BE REQUIRED FOR THE PORTION OF SIDEWALK
 OUTSIDE PUBLIC RIGHT-OF-WAY.
 - PROVIDE DETAILS ON THE ALLEY ABANDONMENT. ALLEY
 ABANDONMENT SHOULD COMPLY WITH CITY CODE SEC. 94-112,
 INCLUDE THE APPLICABLE ADDITIONAL OPEN SPACE
 REQUIREMENT. DEAD-END ALLEY IS PROHIBITED.
  
  
 VALERIO ORICCHIO
 CITY TRANSPORTATION ENGINEER
 561-494-1092
 [email protected]
  