2019-12-11 11:11:26PLANS AND PLATS REVIEW COMMITTEE (PPRC) ZONING REVIEW
 ________________________________________
  
 DATE OF REVIEW: 12.11.2019
 PROJECT NO.: Z19110010
 CASE NO.: PB 791II
 ________________________________________
  
 PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING
 REVIEW COMMENTS:
  
 1. PLEASE CLARIFY THE METHODOLOGY REGARDING THE PARKING
 CALCULATION. A SHARED PARKING CALCULATION IS BEING
 USED, BUT A PARKING STUDY HAS ALSO BEEN PROVIDED TO
 JUSTIFY A FURTHER REDUCTION IN THE REQUIRED PARKING. AS
 SUCH, THE APPLICATION WOULD NEED TO BE AMENDED TO SHOW
 THAT A PARKING WAIVER IS BEING REQUESTED. PARKING
 WAIVERS WITHIN A PLANNED DEVELOPMENT SHALL COMPLY WITH
 SEC. 94-207(B)(13) OF THE CITY?S ZLDRS.
  
 2. PLEASE PROVIDE CLARIFICATION AS TO HOW THE CONFLICTS
 WITH FPL, AS STATED IN THEIR LETTER (NOVEMBER 5, 2019)
 WILL BE ADDRESSED.
  
 3. SITE PLAN SHALL IDENTIFY THE VISIBILITY TRIANGLE AT
 THE CORNER OF CENTREPARK BOULEVARD AND CENTREPARK DRIVE
 EAST. NO ENCROACHMENTS BETWEEN 18 INCHES AND EIGHT (8)
 FEET SHALL BE WITHIN THIS AREA.
  
 4. PLEASE PROVIDE CLARIFICATION ON HOW TRASH WILL BE
 MANAGED AND PICKED UP.
  
 5. PARKING DETAIL ON SHEET SP-1 IS INCORRECT.
  
 5.1. THE NOTE INDICATES TWO (2) FEET TO THE BACK OF THE
 WHEEL STOP, BUT THE DIMENSION LINE INDICATES THREE (3)
 FEET.
  
 5.2. THE LENGTH OF THE STALL IS DIMENSIONED AT 28 FEET;
 THIS SHOULD BE 18 FEET.
  
 5.3. THE WIDTH OF THE HANDICAP STALL IS DIMENSIONED AT
 19 FEET; THIS SHOULD BE 12 FEET.
  
 5.4. THE WIDTH OF THE HANDICAP AISLE IS DIMENSIONED AT
 EIGHT (8) FEET; THIS SHOULD BE FIVE (5) FEET.
  
 6. THE PARKING CONFIGURATION SHOWN ON THE SITE PLAN
 DOES NOT MATCH THE ARCHITECTURAL PLANS.
  
 7. THERE APPEARS TO BE A NUMBER OF LOCATIONS WHERE THE
 STRUCTURAL COLUMNS ARE ENCROACHING INTO THE PARKING
 STALL. THE COLUMNS SHALL BE CONTAINED ENTIRELY WITHIN
 THE DOUBLE-STRIPE AND NOT IMPEDE ON THE MINIMUM WIDTH
 OF THE STALL. A DETAIL MAY NEED TO BE PROVIDED.
  
 8. THE AMENITIES PROVIDED IN THE DETENTION AREA HAVE NO
 ACCESS TO RESIDENTS/PATRONS OF THE BUILDING. THE ONLY
 SIDEWALK THAT CONNECT TO THE PATHWAY IS THAT WHICH HAS
 ACCESS TO THE TRACH ROOM, FPL VAULT, FIRE PUMP, ETC.
 ACCESS SHALL BE PROVIDE TO THE PUBLIC WALKWAY, CAF?
 AND/OR LOBBY AND LEASING AREA.
  
 9. TANDEM PARKING SPACES ONLY WORK IF THEY ARE ASSIGNED
 TO SPECIFIC UNITS. AS SUCH, THESE SPACES CANNOT BE
 CONSIDERED TOWARD THE SHARED PARKING CALCULATION AS
 THEY WOULD NOT BE AVAILABLE FOR USE BY MULTIPLE
 OWNERS/TENANTS.
  
 10. TANDEM PARKING SPACES SHALL NOT HAVE WHEEL STOPS IN
 BETWEEN THE TWO SPACES.
  
 11. THERE?S SOME CONCERN WITH REGARDING THE SINGLE
 PARKING SPACE IMMEDIATELY ADJACENT TO THE LOADING AREA
 ON THE FIRST LEVEL AS IT SEEMS THAT IT WOULD RESULT IN
 CONFLICTS IN INCOMING VEHICLES AS THE SPACE IS
 CONCEALED BEHIND THE WALL.
  
 12. THERE APPEARS TO BE INSUFFICIENT BACK-OUT SPACE OF
 THE FIRST PARKING SPACE AS YOU ENTER THE GARAGE ON THE
 FIRST LEVEL (NORTH SIDE).
  
 13. DIMENSIONS OF BALCONY ENCROACHMENTS SHALL BE
 PROVIDED. BALCONIES SHALL NOT PROJECT MORE THAN THREE
 (3) FEET INTO ANY REQUIRED SETBACK.
  
 14. STAFF DOESN?T QUITE UNDERSTAND THE CONCEPT OF
 HAVING THE ?PLAZA? DESIGN IN FRONT OF THE GROUND FLOOR
 RESIDENTIAL UNITS ALONG CENTREPARK BLVD. WALK-UP UNIT
 DESIGNS SHOULD BE PROVIDED, BUT I BELIEVE SOME LEVEL OF
 PRIVACY NEEDS TO BE ACCOUNTED FOR IN THE DESIGN.
  
 15. WHAT ARE THE ELEVATION DIFFERENCES BETWEEN THE
 CENTREPARK BOULEVARD PLAZA AREA AND THE FINISHED FLOOR
 ELEVATION OF THE GROUND FLOOR UNITS/RETAIL? ARE STEPS
 NEEDED? ACCESSIBLE ROUTES?
  
 16. THE LOCATION OF THE BIKE STORAGE AREAS IN THE
 GARAGE DO NOT SEEM CONDUCIVE FOR USE BY THE RESIDENTS.
  
 17. SETBACKS SHALL BE MEASURED FROM THE PROPERTY LINE
 TO THE CLOSEST POINT OF THE BUILDING. AS THE FITNESS
 ROOM EXTEND BEYOND THE WALL OF THE PARKING GARAGE, THE
 SETBACK SHALL BE MEASURED TO THE EXTERIOR WALL OF THE
 FITNESS ROOM.
  
 18. THE FLOOR PLAN, SITE PLAN, AND ELEVATIONS DO NOT
 SEEM TO CORRESPOND, NOR SHOW ALL ELEMENTS OF THE
 BUILDING. THERE IS INCONSISTENCIES IN THE GROUND LEVEL
 FLOOR PLAN, DECORATIVE FA?ADE ELEMENTS, BALCONIES,
 STRUCTURAL COLUMNS, ETC.
  
 19. DOES STAIR #1 NEED TO HAVE DIRECT EGRESS TO THE
 OUTSIDE OF THE BUILDING? THE SITE PLAN SHOWS A DOOR
 EXITING THE STAIRWELL TO THE CENTREPARK BLVD. PLAZA,
 BUT THE FLOOR PLAN SHOWS THE FIRE COMMAND CENTER IN
 THIS LOCATION WITH EGRESS ONLY THROUGH THE LOBBY.
  
 20. DESIGN CONSIDERATIONS NEED TO BE MADE FOR THE
 FACADES OF THE GARAGE THAT FACE THE CANAL AND THE
 ADJACENT OFFICE BUILDING.
  
 21. PLEASE NOTE THAT THE PROJECT WILL BE SUBJECT TO THE
 CENTREPARK AFFORDABLE AND WORKFORCE HOUSING POLICY THAT
 WAS APPROVED WITH THE ADOPTION OF RESOLUTION NO. 98-17.
 AS REQUIRED BY THE POLICY, THE APPLICATION SHALL
 PROVIDE A WRITTEN CERTIFICATION AS PART OF THE SITE
 PLAN APPLICATION IDENTIFYING WHICH UNITS WILL BE
 OFFERED AS WORKFORCE HOUSING UNITS. PLEASE REFER TO THE
 POLICY FOR ALL UNIT RESTRICTIONS THAT ARE REQUIRED.
  
 22. PLEASE NOTE THAT PURSUANT TO RESOLUTION NO. 98-17,
 UPON OBTAINING SITE PLAN APPROVAL, THE APPLICANT SHALL
 CONTRIBUTE $150/UNIT TO THE WORKFORCE HOUSING TRUST
 FUND, UNLESS THE CITY CHOOSES TO USE IT TOWARD THE
 DEVELOPMENT OF A TRANSIT PLAN TO PROVIDE CONNECTIVITY
 BETWEEN DOWNTOWN AND CENTREPARK. IF THIS OPTION IS
 CHOSEN, THEN THE APPLICANT SHALL WORK WITH THE CITY ON
 THE DEVELOPMENT OF THIS PLAN.
  
 23. PLEASE NOTE THAT PURSUANT TO SECTION 5, CONDITION
 #11 OF RESOLUTION NO. 97-17, ALL IRRIGATION SHALL BE
 PROVIDED UTILIZING THE LAKES (NO POTABLE WATER SHALL BE
 UTILIZED). PLEASE PROVIDE A NOTE ON THE PLANS
 INDICATING COMPLIANCE WITH SUCH PROVISION.
  
 24. PLEASE NOTE THAT PURSUANT TO SECTION 5, CONDITION
 #13 OF RESOLUTION NO. 97-17, WATER-SAVING PLUMBING
 FIXTURES SHALL BE INSTALLED THROUGHOUT THE PROJECT.
 PLEASE PROVIDE A NOTE ON THE PLANS INDICATING
 COMPLIANCE WITH SUCH PROVISION.
  
 25. PLEASE PROVIDE A TURNING RADIUS ANALYSIS FOR THE
 UTILIZATION OF THE LOADING AREA AND DUMPSTER/COMPACTOR.
  
 26. INTERNAL CONNECTION SHOULD BE PROVIDED BETWEEN THE
 RESIDENTIAL LOBBY/LEASING AND THE PROPOSED CAF?/RETAIL.
 ________________________________________
  
 PLEASE NOTE THE FOLLOWING WHEN RESUBMITTING:
  
 A) WRITTEN RESPONSES TO COMMENTS MADE BY ALL
 DEPARTMENTS SHALL BE PROVIDED UPON RESUBMISSION.
  
 B) 15 SETS OF REVISED PLANS AND/OR DOCUMENTS SHALL BE
 PROVIDED, ALONG WITH ONE (1) REDUCED COPY (11IN X
 17IN), AND AN ELECTRONIC COPY OF ALL PLANS.
  
 C) PLEASE NOTE THAT RE-SUBMITTALS MAY BE SUBJECT TO
 ADDITIONAL COMMENTS.
  
 D) IF NO RESPONSE IS RECEIVED WITHIN 60 DAYS OF THE
 ISSUANCE OF THESE COMMENTS, THE APPLICATION WILL BE
 CONSIDERED WITHDRAWN AND ANY FURTHER ACTION WILL
 REQUIRE SUBMISSION OF A NEW DEVELOPMENT APPLICATION.
  
 E) PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1)
 RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY-ISSUED
 COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE
 APPLICANT WILL BE ACCESSED A RESUBMITTAL FEE. SUCH FEE
 WILL BE 20% OF THE ORIGINAL APPLICATION FEE.
  
 F) IN ORDER TO BE CONSIDERED FOR THE FEBRUARY 18, 2020,
 PLANNING BOARD AGENDA, ALL COMMENTS SHALL BE
 SATISFACTORILY ADDRESSED. PLEASE SUBMIT ALL REVISED
 DOCUMENTS/PLANS NO LATER THAN DECEMBER 27, 2019.
  
 G) TO BE PLACED ON THE FEBRUARY 18, 2020, PLANNING
 BOARD AGENDA, SIGNS SHALL BE POSTED ON THE PROPERTY NO
 LATER THAN FEBRUARY 3, 2020. SIGNAGE SHALL CONFORM, AND
 BE INSTALLED ACCORDING TO THE REQUIREMENTS OF THE
 CITY?S ZONING AND LAND DEVELOPMENT REGULATIONS; SUCH
 REQUIREMENTS ARE ALSO PROVIDED IN THE DEVELOPMENT
 APPLICATION. A SIGNED AND NOTARIZED AFFIDAVIT SHALL BE
 PROVIDED BY THE DEADLINE REFERENCED ABOVE.
  
 H) IF AFTER THE CASE HAS BEEN ADVERTISED THE APPLICANT
 DESIRES TO REQUEST A CONTINUANCE, A FEE OF $50 PLUS THE
 COST OF ADVERTISING WILL BE CHARGED.
 ________________________________________
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 JOHN P. ROACH, AICP, PRINCIPAL PLANNER
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION
 401 CLEMATIS STREET - P.O. BOX 3147
 WEST PALM BEACH, FLORIDA 33402
  
 P: 561.822.1448
 TTY: 800.955.8771
 E: [email protected]
  
 W: WPB.ORG
  
  Print


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved