| Date |
Text |
| 2019-11-13 09:42:07 | THIS IS A CONCEPTUAL LEVEL REVIEW. CONSTRUCTION LEVEL |
| | DETAILS, DESIGN CALCULATIONS AND THE POLLUTION |
| | PREVENTION PLAN WILL BE REVIEWED AS PART OF THE |
| | ENGINEERING DEVELOPMENT APPROVAL AND BUILDING PERMIT |
| | APPLICATION PROCESSES. THE ENGINEERING DEVELOPMENT |
| | APPROVAL APPLICATION FORMS CAN BE DOWNLOADED AT |
| | |
| | HTTPS://WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS/FO |
| | RMS,-PERMITS-APPLICATIONS |
| | |
| | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO SITE |
| | PLAN APPROVAL: |
| | |
| | 1. REMOVE THE EXISTING DRAINAGE PIPE FROM THE PARKING |
| | LOT TO THE INLET ON S. DIXIE HWY. |
| | |
| | 2. EXPLAIN WHAT AND 'IDB' IS (SEE CATCH BASIN NO. 2) |
| | |
| | 3. PROVIDE INFORMATION ON THE STORMWATER MANAGEMENT |
| | RETENTION VAULT STORAGE. |
| | |
| | 4. IDENTIFY THE CONTROL STRUCTURE FOR THE EXFILTRATION |
| | TRENCH. |
| | |
| | 5. CALCULATION THE CHANGE IN HGL FOR THE INLET ON |
| | GARDENIA ST. |
| | |
| | 6. ARE THE TRENCH DRAINS ACROSS THE DRIVEWAYS |
| | NECESSARY? THEY APPEAR TO BE AT HIGH POINTS OF THE |
| | DRIVEWAYS. |
| | |
| | 7. EXTEND THE TYPE 'F' CURB AND GUTTER TO THE WEST |
| | PROPERTY CORNER. |
| | |
| | 8. LABEL THE VERTICAL DATUM ON ALL SHEETS WITH |
| | ELEVATION DATA AND PROVIDE THE CONVERSION EQUATION TO |
| | NGVD1929. |
| | |
| | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO |
| | ISSUANCE OF CONSTRUCTION AUTHORIZATION INCLUDING |
| | BUILDING PERMITS AND ENGINEERING DEVELOPMENT APPROVAL. |
| | |
| | 1. AN ENGINEERING DEVELOPMENT APPROVAL APPLICATION MAY |
| | BE REQUIRED FROM THE ENGINEERING SERVICES DEPARTMENT. |
| | THE ENGINEERING DEVELOPMENT APPROVAL APPLICATION FORMS |
| | CAN BE DOWNLOADED AT: HTTP://WPB.ORG/DEPARTMENTS/ENGINE |
| | ERING-PUBLIC-WORKS/FORMS,-PERMITS-APPLICATIONS |
| | |
| | 2. EROSION CONTROL PLAN AND DETAILS TO BE SUBMITTED |
| | WITH THE ENGINEERING PERMIT APPLICATION. |
| | |
| | 3. PROVIDE A COPY OF THE SFWMD ERP PRIOR TO STARTING |
| | CONSTRUCTION. |
| | |
| | TRACY WARD, PE |
| | SENIOR STORMWATER ENGINEER |
| | ENGINEERING SERVICES DEPARTMENT |
| | 561-494-1120 |
| | [email protected] |
| | |
| |
Print |