2020-03-23 14:55:181) ON THE BUILDING PERMIT SUBMITTAL, THE LIFE SAFETY
 PLAN, FLOOR PLAN AND ELEVATIONS SHOW ONLY ONE DOOR ON
 THE WEST FACADE OF THE BUILDING. THE SITE PLAN THAT YOU
 SUBMITTED SHOWS TWO ENTRY POINTS, PLEASE CORRECT TO
 BRING IN LINE WITH THE PERMIT PLANS.
  
 2) THE CIVIL PLANS (BOTH SUBMITTED WITH THE ZONING
 APPLICATION AND THE BUILDING PERMIT) SHOW 16 FOOT DEEP
 PARKING SPACES WITH A TWO FOOT SIDEWALK OVERHANG
 INSTEAD OF WHEEL STOPS ON THE EAST SIDE OF THE
 AUDITORIUM. THE SITE PLAN THAT YOU SUBMITTED SHOWS THE
 TRADITIONAL 18 FOOT DEEP SPACES WITH WHEEL STOPS,
 PLEASE CORRECT TO BRING IN LINE WITH THE PERMIT PLANS.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446