Plan Review Notes
Plan Review Notes For Project Z19090009
Project Number Z19090009
Review Stop Z
Sequence Number 3
Notes
Date Text
2020-03-05 13:12:10CASE NO. PB1248GG - 2ND RESUBMITTAL REVIEW
 MORSELIFE AUDITORIUM & GENERATOR
 4920 LORING DRIVE
  
 - CONTACT ERIC SCHNEIDER @ (561) 822-1446
  
 - PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN
 WRITTEN FORMAT.
  
 - WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF FIVE
 (5) PAPER COPIES AND AN ELECTRONIC COPY IN .PDF FORMAT
 OF ALL PLANS. PLEASE NOTE THAT CHANGES ON THE
 RESUBMITTED PLANS OR THE SUBMITTAL OF INFORMATION/PLANS
 TO ADDRESS THE COMMENTS MAY RESULT IN ADDITIONAL
 COMMENTS.
  
 - PLEASE NOTE THAT IF THE PLANNING DIVISION HAS NOT
 RECEIVED A RESPONSE TO THE COMMENTS WITHIN 60 DAYS FROM
 THE DATE OF THE COMMENTS (BY MAY 7, 2020), THE CASE
 SHALL BE CONSIDERED WITHDRAWN. ANY FURTHER ACTION SHALL
 REQUIRE A NEW DEVELOPMENT APPLICATION.
  
 - PLEASE NOTE THAT SINCE PREVIOUSLY-ISSUED COMMENTS
 WERE NOT ADDRESSED, THE APPLICANT IS ASSESSED A
 RESUBMITTAL FEE. SUCH FEE IS 20% OF THE ORIGINAL
 APPLICATION FEE ($60).
  
 GENERATOR
  
 1) UPDATED COMMENT: THE MASTER PLAN AND SITE PLAN SHOW
 THE GENERATOR ENCLOSURE (INCLUDING THE STAIRS)
 DIMENSION AS 24 FEET X 50 FEET AND 15 FEET IN HEIGHT.
 NO DIMENSIONS ARE PROVIDED ON THE CIVIL PLAN. THE
 GENERATOR ENCLOSURE DRAWING SHOWS THE DIMENSIONS AS 14
 FEET X 47.35 FEET AND 16.67 FEET IN HEIGHT. THE PLANS
 DO NOT SHOW THE GENERATOR ENCLOSURE AS THAT LARGE (IT
 SCALES TO MATCH THE ENCLOSURE DRAWING). THE PLANS NEED
 TO CLEARLY STATE THE CORRECT GENERATOR ENCLOSURE
 DIMENSIONS.
  
 2) UPDATED COMMENT: THE PROPOSED GENERATOR IS
 STRADDLING THE PROPERTY LINE BETWEEN THE MORSELIFE SITE
 AND THE FORMER HOMESAFE SITE. THIS WILL NEED TO BE
 ADDRESSED AS A SPECIFIC DEVELOPMENT REGULATION
 ALLOWANCE WITH THE FORTHCOMING MAJOR PLANNED
 DEVELOPMENT AMENDMENT FOR THE PACE RELOCATION AND
 HOSPICE CONSTRUCTION. STAFF IS UNCLEAR IF YOU ARE
 CONTINUING TO INCLUDE THE GENERATOR WITH THIS
 SUBMITTAL. AT THE PPRC MEETING FOR THE AUDITORIUM IT
 WAS DISCUSSED THAT THE GENERATOR WOULD NO LONGER BE
 WITH THIS MINOR AMENDMENT. PLEASE CLARIFY.
  
 3) NEW COMMENT: THE EXISTING TREE PLAN IS NOT THE PLAN
 (SHEET L102B) SHOWING THE CURRENTLY INSTALLED
 CONDITIONS BASED ON THE RYNA GREENBAUM DRIVE
 RECONFIGURATION. IT SHOWS PRE-RYNA GREENBAUM
 CONDITIONS. USE THE CURRENT LANDSCAPE PLAN AS THE BASE.
  
 CONNECTION
  
 4) REPEAT COMMENT: NO LANDSCAPE PLAN SHOWING THE AREA
 AROUND THE CONNECTION WAS PROVIDED. THE ONLY PLAN
 PROVIDED IS A TREE MITIGATION PLAN (SHEET LA-2 MIT).
 THE MITIGATION PLAN DOES NOT ACCURATELY SHOW THE
 LANDSCAPE ON THE HOMESAFE SIDE OF THE PROPERTY LINE (AS
 SHOWN ON THE APPROVED LANDSCAPE PLAN AND THE PALM BEACH
 COUNTY PICTOMETRY PHOTOS). THE LANDSCAPE PLAN NEEDS TO
 SHOW CODE COMPLIANT LANDSCAPE FOR THE FINAL CONNECTION
 LAYOUT - EX. THE TERMINAL ISLAND ADJACENT TO THE NEW
 CONNECTION IS REQUIRED TO HAVE A TERMINAL ISLAND TREE.
  
 5) NEW COMMENT: THE COMMENT RESPONSE STATES THAT THE
 MITIGATION WILL BE SHOWN ON THE MAJOR AMENDMENT. YOU
 ARE REQUIRED TO PROVIDE THE MITIGATION FOR THE TREES
 REMOVED AS PART OF THIS PROJECT WITH THIS APPLICATION.
  
  