Plan Review Notes
Plan Review Notes For Project Z19090006
Project Number Z19090006
Review Stop L
Sequence Number 2
Notes
Date Text
2020-01-13 17:20:44FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462
 PROJECT: SHOPS AT THE PRESS Z19090006
 JANUARY 13, 2020
 I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND
 PROVIDE THE FOLLOWING COMMENTS:
  
 1. SATISFIED. IDENTIFY THE TREES WITHIN THE AFFECTED
 AREA ON THE TREE DISPOSITION TABULAR LIST TO DISCERN
 THEM FROM THE REST OF THE AREAS.
  
 2. SATISFIED. SECTION 94-448 (D)(3) REQUIRES NATIVE
 TREES IN GOOD CONDITION TO BE PRESERVED ON SITE OR
 RELOCATED. LIVE OAK TREES #529 AND #530 ARE STILL
 LISTED AS GOOD CONDITION, SO MUST BE RELOCATED. LIVE
 OAK TREES #567 AND #568 ARE ALSO LISTED IN GOOD
 CONDITION. IF THEY CANNOT BE RELOCATED FOR ANY REASON,
 OR THE CONDITION HAS CHANGED, INDICATE THIS ON THE
 CHART.
  
 3. SATISFIED. STAFF DOES NOT SUPPORT REMOVAL OF THE
 MATURE BUFFER TREES ALONG THE NORTH PROPERTY LINE THAT
 ARE PROVIDING SHADE FOR THE EXISTING SIDEWALK AND
 PROVIDE ALL THE BENEFITS OF A MATURE TREE CANOPY. THE
 APPLICANT SHOULD LOOK AT PARKING REQUIREMENTS AND
 ADJUST THE PROPOSED NORTH CURB LINE TO FIT THE EXISTING
 CURB LINE IN ORDER TO PRESERVE THE EXISTING TREES AND
 MEET THE INTENT OF SECTION 94-448.
  
 4. SATISFIED. THE SITE DATA DOES NOT SHOW THE LANDSCAPE
 AREA FOR THE SITE WITH THE PROPOSED CHANGES. THIS WAS
 BELOW THE REQUIRED 15% ON THE PREVIOUS APPLICATION AND
 MUST BE CORRECTED TO MEET THE CODE REQUIREMENTS.
  
 5. SATISFIED. PROPOSED LOCATIONS OF FPL TRANSFORMERS
 MUST BE SHOWN ON THE SITE AND LANDSCAPE PLANS.
  
 6. PARTIALLY SATISFIED. WATER BACKFLOW AND FIRE VALVES
 ARE PROPOSED IN THE SOUTHEAST TERMINAL LANDSCAPE ISLAND
 ON THE ENGINEERING PLANS. REQUIRED TREES MUST BE
 INSTALLED IN TERMINAL ISLANDS, SO UTILITIES CANNOT BE
 LOCATED IN POSITIONS THAT WOULD DISPLACE REQUIRED
 TREES. THE TERMINAL ISLAND IS BEING AFFECTED BY
 UTILITIES AND IS WITHIN THE AFFECTED AREA, SO MUST MEET
 CURRENT CODE REQUIREMENTS. THE EXISTING TRIANGLE PALMS
 SHOULD BE REPLACED WITH THE REQUIRED TREE, AND THE
 WATER LINE PLACED TO AVOID THE TREES IN THE LANDSCAPE
 AREAS.
 THE PRESENCE OF THE UTILITIES WITH ROOT BARRIERS
 SEPARATING THE TREE FROM LARGE AREAS OF THE LANDSCAPE
 ISLAND DOES NOT MEET THE INTENT OF THE CODE TO PROVIDE
 THE ROOT ZONE NEEDED TO SUPPORT A CANOPY TREE.
  
 7. PARTIALLY SATISFIED. SECTION 94-443(C)(3) REQUIRES
 THAT A MINIMUM OF 75 PERCENT OF ALL TREES THAT ARE
 REQUIRED TO BE PLANTED WITHIN THE INTERIOR OF AN OFF
 STREET PARKING AREA SHALL BE CATEGORY 1 SHADE TREES. AS
 PROPOSED, THE AFFECTED AREA DOES NOT MEET THIS
 REQUIREMENT. SUGGESTIONS INCLUDE TO REMOVE THE PHOENIX
 CANARIENSIS AND REPLACE WITH A CATEGORY 1 SHADE TREE.
 CLUSIA IS A CATEGORY 1 TREE BUT DOES NOT WORK FOR
 CLEARANCES IN THE PARKING AREA AS PLACED. SELECT OTHER
 SPECIES THAT WILL PROVIDE THE TREE CANOPY. ALSO SEE
 COMMENT #6.
  
 8. SATISFIED. THE LANDSCAPE INTERIOR ISLAND ON THE EAST
 SIDE OF BUILDING 2 DOES NOT MEET THE MINIMUM LANDSCAPE
 WIDTH OF 8 FEET WITHIN THE CURB.
  
 9. NOT SATISFIED. FLORIDA FRIENDLY DESIGN OPTIONS CHART
 NEEDS TO BE UPDATED TO CURRENT CODE AND POINTS
 RECALCULATED.
 CHECK ALL ITEMS ON CHART AGAINST CURRENT CODE
 94-442(G).
  
 10. SATISFIED. SHOW LOCATIONS OF ANY ROOT BARRIERS
 REQUIRED TO PROTECT UTILITY LINES.
  
 11. SATISFIED. THE EXHIBIT SHOWING THE PARKING AREA
 SURFACE CALCULATIONS, PARKING SPACE AREAS AND LANDSCAPE
 AREAS PROVIDED TO DEMONSTRATE COMPLIANCE WITH SECTIONS
 94-443 (C)(3) AND (4) INCLUDES AREAS THAT CROSS THE
 AFFECTED AREA LINE
  
 12. PARTIALLY SATISFIED. SHOW ALL REQUIRED CURBS
 ADJACENT TO LANDSCAPE AREAS PER SECTION 94-443 (C)(5).
 THE AREA ADJACENT TO THE DUMPSTER DOES NOT HAVE A CURB
 FOR PROTECTION. THERE IS ALREADY A CONFLICT WITH THE
 EXISTING TREE ROOT SYSTEM AND THE PAVED AREA.
  
 13. SATISFIED. STAFF SUGGEST AN ADDITIONAL SPECIES BE
 USED FOR THE WEST BUFFER AS THE GEIGER TREES ARE NOT
 THE BEST PERFORMING SPECIES FOR THIS AREA AND LOOK BAD
 FOR A MAJOR PORTION OF THE YEAR.
 ADDITIONAL COMMENTS 1/13/20:
 14. THE RECONFIGURATION OF THE AREA BEHIND BUILDING 1
 REQUIRES TERMINAL LANDSCAPE ISLANDS ADJACENT TO THE ADA
 SPACES.
  
 15. TREE #549 IS NOT SHOWN ON THE TREE DISPOSITION PLAN
 AS BEING REMOVED BUT FALLS WITHIN AN AREA PROPOSED TO
 BE PAVED ON THE SITE PLAN AND LANDSCAPE PLAN.
  
 16. THE TREE DISPOSITION SUMMARY SHALL BE EDITED TO
 SHOW THE TREES AND CANOPY REMOVED AND TO BE REPLACED
 WITH THE MINOR AMENDMENT AND ALREADY PERMITTED AS
 SEPARATED FROM THE REST OF THE SITE. THE SUMMARY SHOULD
 SHOW SEPARATED INTO 2 PHASES.
  
  
  
 CONDITIONS OF APPROVAL
 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON
 THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE
 SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT
 SERVICES DEPARTMENT, PLANNING DIVISION.
  