| 2020-04-06 08:53:04 | COMMENTS PROVIDED FOR THE 3-10-2020 RESUBMITTAL |
| | 1. THE NW CORNER FA?ADE NEEDS ADDITIONAL DESIGN WORK. |
| | THE NORTH ELEVATION OF THE TOWER IS ABSENT OF ANY |
| | FENESTRATION, AND THIS FA?ADE WILL BE HIGHLY VISIBLE |
| | FROM DIXIE HIGHWAY. |
| | 2. THE GROUND FLOOR NORTH ELEVATION (VISIBLE FROM THE |
| | NORTH) COULD BE ENHANCED WITH ADDITIONAL ARCHITECTURAL |
| | TREATMENT, POSSIBLY SOME OPENINGS AND LANDSCAPE. THE |
| | UPPER FLOORS ALSO NEED ARCHITECTURAL TREATMENT TO |
| | SCREEN THE GARAGE (UP TO THE POINT WHERE THE COUNTY |
| | GARAGE STARTS). LANDSCAPE AT THE GROUND FLOOR NEEDS TO |
| | BE ADDED TO HELP WITH THE SCREENING. THE LA DRAWINGS DO |
| | NOT SHOW ANYTHING ON THAT AREA. |
| | 3. PLEASE CLARIFY THE DETAILS OF THE BANYAN AND DIXIE |
| | BUILDING CORNER AT GROUND FLOOR. RENDER IN Z.3 AND |
| | ELEVATIONS SHOW A SOLID ELEMENT FRAMING THE DOORS ON |
| | BOTH SIDES, BUT FLOOR PLAN JUST INDICATES GLAZING. THE |
| | CORNER COLUMN/WINDOW FRAME IS ALSO SHOWN WITH A LARGER |
| | PROFILE THAN THE ONE INDICATED IN THE FLOOR PLAN. |
| | 4. THE PORTION OF THE WEST FA?ADE WHERE THE STAIR IS |
| | NEEDS ADDITIONAL TREATMENT. |
| | 5. PLEASE DIMENSION THE CANOPY PROJECTIONS FOR THE |
| | ENTIRE PROJECT, AND SPECIFY MATERIAL (SOME ERRORS ON |
| | CALL OUTS) |
| | 6. PLEASE LOCATE ANY PORTION OF THE DCDA AND RPBA THAT |
| | PROJECT ABOVE GROUND BEHIND THE BUILDING FA?ADE. IF |
| | POSSIBLE, PROVIDE SPACE FOR LANDSCAPE SCREENING ALONG |
| | THE FRONTAGE. |
| | 7. PLEASE DISCUSS WITH THE FIRE DEPARTMENT IF THE FIRE |
| | DEPT COMMAND ROOM CAN BE RELOCATED TO THE EAST SIDE OF |
| | THE GARAGE, WITH ACCESS FROM THE SURFACE PARKING LOT. |
| | THE RELOCATION OF THE FIRE COMMAND ROOM WILL ALLOW |
| | APPLICANT TO INCREASE THE GROUND FLOOR ACTIVE USE AND |
| | REDUCE THE VARIANCE REQUEST. |
| | 9. THE RENDERINGS SHOW THAT THE EAST ELEVATION OF THE |
| | GARAGE HAS A GREEN WALL GROWING FROM THE STRIP OF |
| | LANDSCAPE EAST OF THE WALL, BUT THE LANDSCAPE DRAWINGS |
| | DO NOT HAVE ANY PLANT MATERIAL SPECIFIED THERE. PLEASE |
| | ADJUST THE LA DRAWINGS TO REFLECT THE APPROPRIATE |
| | PLANTS TO CREATE THE GREEN WALL. A GREEN WALL IS A GOOD |
| | SCREENING ENHANCEMENT FOR THE GARAGE. |
| | 10. THE SAME EAST GARAGE RENDERING SHOWS A VINE GROWING |
| | DOWN FROM THE POOL DECK TO SCREEN THE GARAGE, WHICH |
| | COULD BE A GOOD ADDITION. HOWEVER, THE SPECIFIED PLANT |
| | MATERIAL AT THE POOL DECK IS A CLUSIA GUTTIFERA WHICH |
| | IS A HEDGE TYPE PLANT. PLEASE CHANGE TO REFLECT A VINE |
| | TYPE OF PLANT. |
| | 11. FOR THE PROPOSED GARAGE SCREENING WE NEED THE |
| | FOLLOWING ADDITIONAL INFORMATION: |
| | O PLEASE PROVIDE A PLAN VIEW DETAIL OF THE GARAGE |
| | SCREEN TO INDICATE THE DEPTH VARIATION BETWEEN THE |
| | PANELS. |
| | O METAL SLAT PANEL DEPTH IS NOT ENOUGH TO CREATE ANY |
| | SHADOW EFFECT. STAFF RECOMMENDS AT LEAST A 4? DEPTH. |
| | O EAST SIDE OF GARAGE NEED ADDITIONAL PANELS TO |
| | SUCCESSFULLY PRODUCE THE ?DISSOLVING? EFFECT INTENDED. |
| | O RENDERINGS SHOW WALL PANEL SYSTEM WITH A COLOR |
| | VARIATION, HOW IS THAT VARIATION GOING TO BE ACHIEVED? |
| | PLEASE PROVIDE COLOR SAMPLES. |
| | O WHAT IS THE DEPTH OF THE REVEAL FOR THE WALL PANEL |
| | SYSTEM? |
| | O PLEASE CONFIRM THE GARAGE IS A MECHANICALLY |
| | VENTILATED GARAGE. |
| | |
| | 12. ADDITIONAL ARTICULATION SHALL BE PROVIDED TO |
| | SEPARATE THE PAINT COLOR AT THE BASE FROM THE TOP |
| | (SOUTH ELEVATION, AREA ABOVE LOBBY ENTRANCE). CURRENTLY |
| | IS ONLY SEPARATED BY A REVEAL. |
| | 13. THE WIDTH OF THE CAP ELEMENT SEPARATING THE BASE |
| | FROM THE TOP ALONG BANYAN BLVD IS DIFFERENT FROM THE |
| | ONE ALONG DIXIE HIGHWAY. SHOULD THEY BE CONSISTENT? |
| | 14. RENDERINGS SHOW LARGE TREES AT THE ROOF TOP TERRACE |
| | LOCATED ON THE NW CORNER OF THE BUILDING (ON TOP OF |
| | GARAGE), BUT LA DRAWINGS DO NOT INDICATE ANY PLANT |
| | MATERIAL ON THAT TERRACE. A VINE SIMILAR TO THE ONE |
| | INDICATED ON THE GARAGE SCREENING AT THE EAST COULD BE |
| | A GOOD ADDITION. |
| | 15. VIS.1 CONTEXT ELEVATION NEEDS TO INCLUDE THE |
| | COURTHOUSE BUILDING. |
| | 16. THE PLANT MATERIAL (CLUSIA GUTTIFERA) ADJACENT TO |
| | THE ON-STREET PARKING SPACE NEEDS TO BE MODIFIED BY A |
| | PLANT MATERIAL THAT ALLOWS PEOPLE TO STEP OUT OF THEIR |
| | CARS (PERENNIAL PEANUT COULD BE AN OPTION). |
| | 17. PLEASE REDUCE THE WIDTH OF THE CURB CUTS TO 20 FEET |
| | SO THE MAXIMUM WIDTH AT THE CURB SIDE IS 25 FEET. |
| | 18. THE PROPOSED BANYAN STREETSCAPE DESIGN DOES NOT |
| | INCLUDE BRICK PAVERS ON THE SIDEWALK. PLEASE REMOVE |
| | PAVERS FROM DESIGN. PAVERS CAN ALSO BE REMOVED FROM THE |
| | DIXIE FRONTAGE AS DIXIE DOES NOT HAVE PAVERS ON |
| | SIDEWALK EITHER. |
| | 19. THE THREE TREES ALONG THE BANYAN FRONTAGE OF THE |
| | EXISTING OFFICE BUILDING SHALL BE INSTALLED IN TREE |
| | GRATES AND NOT WITH BASE PLANTING AS THE SIDEWALK IS |
| | ONLY OVER 6 FEET. |
| | 20. PLEASE CORRECT PARKING STRIPPING DETAIL TO REFLECT |
| | CITY STANDARD. |
| | 21. PLEASE INCLUDE A DETAIL NOTE ON THE CIVIL DRAWINGS |
| | STATING THE SIDEWALK ELEVATION SHALL BE MAINTAINED AS |
| | IT CROSS OVER THE DRIVEWAY. |
| | 22. PLEASE REMOVE THE SMALL MEDIAN AT THE WEST PARKING |
| | ENTRANCE (SHEET AS-1) AND REDUCE THE DRIVEWAY TO 20 |
| | FEET. |
| | 23. PLEASE REDUCE PARKING LOT DRIVEWAY TO 20 FEET IN |
| | WIDTH. |
| | 24. PLEASE PROVIDE PHOTOMETRICS FOR THE SIDEWALK AREA |
| | AND PUBLIC OPEN SPACE AND INCLUDE THE STANDARD LIGHT |
| | FIXTURE DETAIL FOR THE DOWNTOWN FOR ALL FIXTURES WITHIN |
| | THE ROW. |
| | 25. PLEASE PROVIDE INFORMATION TO CONFIRM COMPLIANCE |
| | WITH PLANAR BREAK REQUIREMENTS, TRANSPARENCY |
| | REQUIREMENTS, MAXIMUM FOOTPRINT, BLANK WALL REQUIREMENT |
| | ETC. |
| | 26. PLEASE USE THE GUIDELINES OF DRAWING SUBMITTAL TO |
| | ENSURE ALL THE INFORMATION IS PROVIDED AND COMPLIANCE |
| | CAN BE VERIFIED. |
| | PLEASE RESUBMIT REVISED DRAWINGS AND A RESPONSE LETTER. |
| | FOR ADDITIONAL INFORMATION PLEASE CONTACT ANA MARIA |
| | APONTE AT 561-822-1439. |
| |