| 2019-09-11 12:12:44 | 1. PLEASE PROVIDE INFORMATION TO CONFIRM COMPLIANCE |
| | WITH PLANAR BREAKS, FACADE ARTICULATION, ACTIVE USE AND |
| | OTHER DESIGN REQUIREMENTS. USE GUIDELINES. |
| | 2. PLEASE INCLUDE RESIDENTIAL BIKE PARKING REQUIREMENTS |
| | 1/15 REQUIRED PARKING SPACES. IN ADDITION, 1 BIKE |
| | PARKING SPACE REQUIRED FOR RETAIL USE. BOTH SHALL BE |
| | INSIDE THE GARAGE. |
| | 3. PLEASE IDENTIFY THE LOCATION AND PROVIDE DETAILS FOR |
| | THE REQUIRED BIKE PARKING FOR GENERAL PUBLIC TO BE |
| | LOCATED WITHIN THE PUBLIC REALM. |
| | 4. PLEASE DIMENSION THE PARKING SPACES INSIDE THE |
| | GARAGE TO CONFIRM COMPLIANCE. CONFIRM COMPLIANCE WITH |
| | SECTION 94-111(C). |
| | 5. PLEASE PROVIDE A GROSS BUILDING AREA TABLE. CLARIFY |
| | WHAT IS THE BOH SPACE ON FLOORS 7TH TO 16TH. |
| | 6. PLEASE LABEL GARAGE 2ND LEVEL AS MEZZANINE SO IT IS |
| | CLEAR THE BUILDING IS ONLY 15 STORIES. |
| | 7. PLEASE EXPLAIN HOW THE TRASH PICK- UP OPERATION FOR |
| | THE RESIDENTIAL BUILDING IS, AND WHERE IS THE DUMPSTER |
| | FOR THE EXISTING OFFICE BUILDING. |
| | 8. THE WEST LANDSCAPE BUFFER FOR THE SURFACE PARKING |
| | LOT IS NOT IN COMPLIANCE WITH THE MINIMUM FIVE FOOT |
| | WIDTH. |
| | 9. PLEASE PROVIDE AUTOTURN FOR LOADING AREA. |
| | 10. STREETSCAPE SHALL BE COORDINATED WITH THE BANYAN |
| | STREETSCAPE PROJECT CURRENTLY UNDER DESIGN PHASE BY THE |
| | CITY. |
| | 11. PLEASE PROVIDE COLORED ELEVATIONS WITH CALL OUT |
| | MATERIAL AND PICTURES OF SPECIAL MATERIALS AND |
| | FINISHES. |
| | 12. PLEASE PROVIDE COLORED ELEVATIONS INSERTED IN THE |
| | CONTEXT. |
| | 13. PROPOSED PROJECT DOES NOT COMPLY WITH ACTIVE USE |
| | REQUIREMENT ALONG DIXIE HWAY OR BANYAN BOULEVARD. |
| | 14. PARKING GARAGE TREATMENT DOES NOT SEEM TO COMPLY |
| | WITH NON-ACTIVE USE FA?ADE ARTICULATION REGULATIONS. |
| | 15. PUBLIC OPEN SPACE DOES NOT COMPLY WITH MINIMUM |
| | ACTIVE USE ABUTMENT. MINIMUM 25% REQUIRED, PROJECT |
| | PROVIDES 18.7%. PLEASE STUDY ALTERNATIVES TO COMPLY |
| | WITH REQUIREMENT. |
| | 16. PALM BEACH COUNTY PROPERTY APPRAISER?S WEBSITE |
| | LISTS TOTAL SQUARE FOOTAGE FOR EXISTING BUILDING AT |
| | 44,590SF VS 40,000 LISTED IN PROJECT DATA. PLEASE |
| | PROVIDE DETAIL INFORMATION TO CONFIRM THE SQUARE |
| | FOOTAGE OF EXISTING BUILDING. |
| | 17. EXISTING OLIVE TREES ALONG BANYAN AND OLIVE AVENUE |
| | SHALL BE REPLACED WITH NEW TREES PLANTED WITH THE |
| | REQUIRED STRUCTURAL SOIL AROUND IT. |
| | 18. PLEASE STUDY THE POSSIBILITY TO REDUCE THE NUMBER |
| | OF CURB CUTS FOR THE PROJECT TO MINIMIZE PEDESTRIAN |
| | IMPACT. THE BANK DRIVE THRU LANES COMBINED WITH THE |
| | PARKING ACCESS CREATES A 56 FOOT WIDE CURB CUT, VERY |
| | DANGEROUS FOR PEDESTRIANS.STUDY THE POSSIBILITY TO MOVE |
| | DRIVE THRU NORTH TO ALLOW ONLY ONE EXIT INTO THE STREET |
| | AND PROVIDE A LANDSCAPED MEDIAN. |
| | 19. PLEASE PROVIDE PHOTOMETRICS FOR THE STREET TO |
| | CONFIRM COMPLIANCE WITH MINIMUM 0.6 FOOTCANDLE |
| | REQUIRED. DECORATIVE LIGHT FIXTURES ARE REQUIRED ALONG |
| | THE STREET FRONTAGE. POLE AND FIXTURE SHALL MEET |
| | DOWNTOWN STANDARD. |
| | 20. PLEASE PROVIDE TERMINAL ISLAND FOR ANGLE PARKING |
| | FROM OLIVE AVENUE. |
| | 21. REDUCE CURB CUT ON OLIVE AVENUE TO THE MINIMUM |
| | NEEDED FOR ONE WAY ACCESS. |
| | 22. DRIVEWAYS SHALL MAINTAINED THE SIDEWALK ELEVATION. |
| | FOR RESUBMITTAL, PLEASE PROVIDE EIGHT REVISED SETS, ONE |
| | 11 BY 17 SET, AND A CD WITH ALL INFORMATION. INCLUDE |
| | RESPONSE LETTERS ADDRESSING ALL COMMENTS WITH EACH |
| | COPY. |
| | |
| |